PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Some solutions of unsteady flow in bioreactor

Identyfikatory
Warianty tytułu
PL
Pewne rozwiązania nieustalonego przepływu w bioreaktorze
Konferencja
Modelowanie w mechanice. Sympozjon PTMTS (43 ; 9-13.02.2004 ; Gliwice, Polska)
Języki publikacji
EN
Abstrakty
EN
The articular cartilage is considered a tissue without the capacity to repair, thus mechanical wear of tissue joint is often designated as a normal tribute to increasing age. The tissue engineering of cartilage implants of human joints has very important significance for treatments by transplantation of various cartilage diseases. The tissue is gained from resected fragments of human joint during total knee replacement. Dynamic, unsteady flow of nutrient liquids in bioreactor provides efficient oxygen supply and hence secures the best overall tissue structure and composition for engineered cartilage. The aim and new element of presented paper is the method of some particular solutions of unsteady flow parameters in bioreactor.
PL
Czas regeneracji chrząstki stawowej po urazie jest bardzo długotrwały. Czasem nawet tkanka chrząstki stawowej nie regeneruje się. Dlatego też wszczepianie przeszczepów chrząstki nabiera bardzo ważnego znaczenia. Przeszczepy hodujemy w bioreaktorach. Najlepsze efekty hodowli uzyskujemy w bioreaktorach wykonujących ruch obrotowy i zapewniających nieustalony charakter przepływu cieczy odżywczej. Dlatego tematem niniejszego artykułu są pewne metody i rozwiązania nieustalonego przepływu cieczy w warstwie przyściennej hodowanej chrząstki stawowej w bioreaktorze.
Rocznik
Tom
Strony
439--444
Opis fizyczny
Bibliogr. 8 poz.
Twórcy
  • Tech. Univ. Gdansk, Faculty of Ocean Eng. & Ship Technology
autor
  • Central Institute for BioMedical Engineering University Ulm, Germany
Bibliografia
  • [1] Fung, Y.C.: Biomechanics: Mechanical Properties of Living Tissues:ed.Springer Verlag New York, 220-241 1993.
  • [2] Fung Y.C.: Biomechanics, Motion, Flow, Stress and Growth. Springer Verlag,New York-Hong Kong ,1990.
  • [3] Mow, V.C.,Wang,C.C.: Some bioengineering considerations for tissue engineering of articular cartilage. Clin. Orthop. 1999, 367,204-223.
  • [4] Raimondi,M.T.,Boschetti, F.,Falcone,L.,Fiore,G.B.,Remuzzi,A.,Marinonni,E.,Marazzi, M.,Pietrabissa,R.: Mechanobiology of engineered cartilage cultured under a quantified fluid-dynamic environment. Biomechanics and Modeling inMechanobioIogy,2002, 69- 82
  • [5] Teipel, I.: The Impulsive Motion of a Flat Plate in a Viscoelastic Fluid. Acta Mechanica, 1981,9,277-279.
  • [6] Truckenbrodt, E.: Strbmungsmechanik: Springer Verlag,Berlin,New.. York (in German),1986.
  • [7] Truesdell.C.: A First Course in Rational Continuum Mechanics John Hopkins University: Baltimore, Maryland, 1972.
  • [8] Trzeciak T.,Kruczyński J.Lubiatowski P.,Piontek T.,Jaroszewski J.: The reconstruction of defects in articular cartilage using analogous chondrocytes.Ortopedia Traumatologia Rehabilitacja, Vol.3, Nr.2, 2001, 200-204.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BSL3-0023-0100
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.