Indoor climate and energy consumption in buildings with natural ventilation

Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The most important criteria for evaluation of building engineering is the state of indoor climate and energy consumption. Increase of the rate of energy saving resulted not only in the use of better barriers, but also building elements, such as windows having low air leakage values. Simultaneously, in the designs of new buildings and the retrofit of existing buildings, traditional structure of natural ventilation is used. In these cases, the ventilation is an important tool for a desirable realization of all environmental and energy requirements. The paper presents selected results of long-term research work. These results were obtained by questionnaires, measurements and simulations of ventilation and heating processes in typical detached houses, blocks of flats and office buildings. The main objective of the presented paper is to demonstrate investigations and summarize a large number of results which describe the airtightness and natural ventilation on indoor environment and energy consumption. In conclusion, ways of airtightness, ventilation and heating strategies are presented.
PL
Jednymi z najważniejszych kryteriów dla oceny budynków jest stan klimatu wewnętrznego i zużycie energii. Silne tendencje do oszczędzania energii skutkują nie tylko stosowaniem lepszych przegród, ale również elementów budowlanych, takich jak okna, charakteryzujących się dużą szczelnością. Jednocześnie, w budynkach nowych oraz istniejących i modernizowanych, stosowane są tradycyjne rozwiązania wentylacji. W takich przypadkach działanie wentylacji staje się istotnym czynnikiem dla realizacji wymagań energetycznych i środowiskowych. Poniżej przedstawiono wybrane wyniki wieloletnich badań. Wyniki te uzyskano drogą badań ankietowych, kompleksowych pomiarów w jednorodzinnych, wielorodzinnych i biurowych budynkach istniejących oraz symulacji komputerowej procesów wentylacyjnych. Celem opracowania jest zaprezentowanie i podsumowanie dużej liczby badań opisujących wpływ wentylacji naturalnej i szczelności przegród na stan środowiska wewnętrznego.
Rocznik
Strony
107--118
Opis fizyczny
Bibliogr. 15 poz.
Twórcy
autor
  • Department of Heating, Ventilation and Dust Removal Technology, The Silesian University of Technology, Konarski Str. 20, PL 44-100 Gliwice, Poland, marian.nantka@polsl.pl
Bibliografia
  • [1] Fanger, P.O.; Indoor air quality in the 21 century, Indoor Air 10, 2000, p. 68-73
  • [2] Bluessyn, P.M. & Cox, C; Indoor environment quality and upgrading of European office buildings. Energy and Buildings 34, 2002, p. 155 - 162
  • [3] Kaczmarczyk, J.& Melikov A. & Bolashikov, Z. & Nikolaew, L. & Fanger, P.O., Human Responses to Five Designs of Personalized Ventilation, HVAC&R Research, vol.12, no.2, USA
  • [4] Nantka, M.B.; Air Infiltration and Ventilation in Relation to the Thermal Performance of Dwelling Houses, Building Services Engineering, Research and Technology, vol. 7, no.1, 1986, p. 11 - 19, UK
  • [5] Nantka, M.B.; Airtightness and Natural Ventilation: A Case Study in Poland, The International Journal of Ventilation, vol.4, no.1, 2005 79-93, UK
  • [6] Baranowski, A. & Ferdyn-Grygierek, J.; Integrated simulation of heat demand and air exchange in a multi-family building, Proceedings of International Conference on Dynamic analysis, simulation and testing applied to the energy and environmental performance of buildings, Office for Official Publications of the European Communities. 2006
  • [7] Leigh-Smith, S.; Carbon Monoxide Poisoning in Tents, Wilderness and Environmental Medicine, vol.15, no.3, 2004, 157-163, USA
  • [8] Persily, A.K.; Carbon Monoxide Dispersion in Residential Buildings, National Institute of Standards and Technology 5906, USA
  • [9] Pach, J.& Hubalewska-Hokla, A.; Scintigraphic detection of cardiac injury of actually carbon monoxide poisoned patients, Journal of Toxicology Clin. Toxicology., 2001, 522
  • [10] Kukkonen, £.; Indoor Climate - Questionnaires, investigation and remedial measures, Nordtest Finland TN-Report no.294. This report was presented on the VI International Conference on Indoor Air Quality and Climate in Finland, 1993
  • [11] Nantka, M.B., Indoor Environment in Buildings with Natural Ventilation, Archives of Environmental Protection - Polish Science Academy, no.1, 2006. Poland
  • [12] Feiistel, H.E.& Dieris, J.; A Survey of Air Flow Model for Multizone Structures, International Report of Lawrence Berkeley Laboratory CA no. 94720, 1991. USA
  • [13] Nantka, M.B.; A Method for Prediction of Air Flows in Multizone Buildings, Archives of Civil Engineering, Polish Scientific Academy, no.2, 1996 237-267, Warsaw, Poland
  • [14] Walton, G.N.; Contam, National Institute of Standards and Technology Documents, no.5385, 2002 USA
  • [15] Nantka, M.B.; Indoor Air Quality and Health Hazard in Dwellings with Natural Ventilation and Gas Appliances”, Proceedings of 3rd International Conference on Energy and Gas, Gliwice, Poland, 2005