PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Static and dynamic response of cost effective unreinforced brick masonry buildings

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Statyczna i dynamiczna odpowiedź efektywnych ekonomicznie budynków murowanych o niezbrojonych, ceglanych ścianach
Języki publikacji
EN
Abstrakty
EN
Besides the buildings with conventional one-brick thick solid masonry walls, two cost effective masonry wall constructions, viz. reduced thickness and cavity wall, have been studied for their lateral load resistance. The reduced thickness of wall was constructed with a combination of bricks on bed and bricks on edge; whereas the cavity wall was constructed with bricks on edge in Flemish bond using solid firedearth bricks. Single storey one-room building models were subjected to static lateral load and shake table tests. The study shows that there is considerable reduction in shear strength of buildings with cost effective masonry and the reduction is more than the saving in the material, which is due to increase in the vertical mortar joints in both masonry types. The base isolation system, using Teflon sheet, shows great promise for adoption in conventional as well as the cost effective building construction as a measure of earthquake safety.
PL
W uzupełnieniu do konwencjonalnych budynków o murowanej konstrukcji ścian z cegły w pracy zaprezentowano dwa typy budynków charakteryzujące się ekonomicznie efektywną konstrukcją ścian, uzyskaną poprzez: zmniejszenie ich grubości oraz zastosowanie pustki powietrznej. Jedno piętrowe modele budynków poddano analizie w zakresie statycznym pod względem odporności na obciążenie boczne oraz testowano ze względu na dynamiczne wymuszenia za pomocą stołu wzbudzającego. Wyniki badań wskazują, że istnieje znacząca redukcja w wytrzymałości na ścinanie budynków o zaproponowanej ekonomicznej konstrukcji murowanych ścian i jest ona bardziej znacząca niż oszczędności materiałowe, które wynikają ze wzrostu spoin pionowych w obu rozpatrywanych typach murów. Efektywność systemu izolacji podłoża przy pomocy przekładki teflonowej wskazuje na duże możliwości zaadoptowania go w budynkach tradycyjnych, jak i tych o ekonomicznej konstrukcji ścian, jako środek ich bezpieczeństwa w trzęsieniach ziemi.
Rocznik
Strony
921--941
Opis fizyczny
Bibliogr. 21 poz., rys., tab., wykr.
Twórcy
autor
autor
  • Department of Civil Engineering, Aligarh Muslim University, Aligarh 202 002, India
Bibliografia
  • [1] Arya A.S., Chandra B., Qamaruddin M.: A new concept for resistance of masonry buildings in severe earthquake shocks, Journal of the Institution of Engineers India, Vol. 61, 1981, pp. 302-308.
  • [2] Arya A.S.: Sliding concept for mitigation of earthquake disaster to masonry buildings, In: Proceedings 8th World Conference on Earthquake Engineering, San Francisco, Vol. 5, 1984, pp. 951-958.
  • [3] Bruneau M.: State-of-the-Art report on seismic performance of unreinforced masonry building, Journal of Structural Engineering, Vol. 120, 1994, pp. 925-945.
  • [4] Derham C.J., Kelly J.M., Thomas A.G.: Non-linear natural rubber bearings for seismic isolation, Journal of Earthquake Eng. & Structural Dynamics, Vol. 84, 1985, pp. 417-428.
  • [5] IS 1077, Specification for commonly burnt clay building bricks, Bureau of Indian Standards (BIS), India, 1976.
  • [6] IS 2212, Code of practice for brickwork, BIS, India, 1962.
  • [7] IS 2250, Code of practice for preparation and use of masonry mortar, BIS, India, 1981.
  • [8] IS 269, Specification for ordinary and low heat Portland cement, BIS, India, 1976.
  • [9] IS 3495, Methods of tests of burnt clay building bricks, BIS, India, 1976.
  • [10] IS 383, Specification for coarse and fine aggregates from Natural Resources, BIS, India, 1970.
  • [11] Keswani K.: The contribution of building centres to low-cost housing in India, Building Research & Information, Vol. 25, 1997, pp. 50-64.
  • [12] Lin B.C. et al.: Response of base isolated buildings to random excitation described by C-P spectral model, Journal of Earthquake Engineering & Structural Dynamics, Vol. 18, 1989, pp. 49-62.
  • [13] Majid S.A., Qadeer A., Farrukh A.: Dynamic behaviour of multistoreyed brick building models, In: Proceedings of 10th Symposium on Earthquake Engineering, University of Roorkee, India, Vol. 2, 1994, pp. 983-988.
  • [14] Mostaghel N., Hejazi M., Tanbakuchi J.: Response of sliding structures to harmonic motion, Journal of Earthquake Eng. & Structural Dynamics, Vol. 11, 1983, pp. 355-366.
  • [15] Mostaghel N., Khodaverdian M.: Dynamics of resilient friction base isolator (R-FBI), Journal of Earthquake Engineering & Structural Dynamics, Vol. 116, 1987, pp. 839-854.
  • [16] Qamaruddin M., Rasheeduzzafur, Arya A.S., Chandra B.: Seismic response of masonry buildings with sliding substructure, Journal of Structural Engineering, Vol. 112, 1986, pp. 2001-2011.
  • [17] Qamaruddin M.: Development of brick building systems for improved earthquake performance, Ph. D. Thesis, University of Roorkee, Roorkee, India, 1978.
  • [18] Raman P.G.: Structural masonry and architectural expression, Construction and Building Materials, Vol. 18, 2004, pp. 133-139.
  • [19] Sengupta N.: Use of cost-effective construction technologies in India to mitigate climate change, General Articles, current science, Vol. 94, 2008.
  • [20] Tomazevic M., Weiss P.: Seismic behaviour of plain and reinforced masonry build building, Journal of Structural Engineering, Vol. 120, 1994, pp. 323-337.
  • [21] Yan Z., David T., John C.: Nonlinear dynamic analysis of unreinforced masonry, Journal of Structural Engineering, Vol. 125, 1998, pp. 270-277.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ5-0020-0018
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.