Tytuł artykułu
Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Nowa nieniszcząca metoda pomiaru stopnia korozji z użyciem polaryzacji liniowej
Języki publikacji
Abstrakty
Corrosion of steel reinforcement is one of the most common causes of end service life in reinforced concrete structures. Corrosion is initiated and propagates unseen beneath the concrete cover and it is difficult to evaluate the severity of the problem. The most promising electrochemical method is the Linear Polarisation Resistance method which can provide a direct evaluation of the instantaneous rate of corrosion. The main drawback to this technique is that it requires a localized breakout of the concrete cover to provide an electrical connection to the steel reinforcement. This article describes an adaptation of the LPR method and the four-point Wenner resistivity method to give an assessment of the rate of steel corrosion without the requirement for a direct connection to the reinforcement. The measurements have been performed in cooperation with Construction and Infrastructure Group in University of Liverpool.
Korozja stali zbrojeniowej w betonie jest jedną z głównych przyczyn degradacji konstrukcji żelbetowych. Korozja jest inicjowana i propagowana przez otulinę zbrojenia i wobec tego jest niezmiernie trudno ocenić znaczenie tego problemu. Najbardziej obiecującą elektrochemiczną metodą jest metoda polaryzacji liniowej, za pomocą której można w sposób bezpośredni wyznaczyć stopień korozji. Główną wadą metody jest konieczność odkucia betonowej otuliny w celu zapewnienia elektrycznego dostępu elektrody do zbrojenia. Artykuł opisuje adaptację metody polaryzacji liniowej wraz z metodą Wennera pomiaru oporności betonu do oceny stopnia korozji stali zbrojeniowej w betonie bez konieczności bezpośredniego kontaktu ze zbrojeniem. Badania zostały przeprowadzone przy współpracy z Construction and Infrastructure Group z University of Liverpool.
Czasopismo
Rocznik
Tom
Strony
109--116
Opis fizyczny
Bibliogr. 11 poz., rys., tab., wykr.
Twórcy
autor
- Wrocław University of Technology, Wybrzeże Wyspiańskiego 25, 50-370 Wrocław, Poland
Bibliografia
- [1] Pullar-Strecker P.: Concrete reinforcement corrosion: From assessment to repair decisions, Thomas Telford, 2002.
- [2] Standard test method for half-cell potentials of uncoated reinforcing steel in concrete, C876-91, ASTM: Philadelphia, 1991.
- [3] Broomfield J., Millard S.: Measurement of concrete resistivity to assess corrosion rates, Concrete, 2002, pp. 37–39.
- [4] Wenner F.: A method of measuring earth resistivity, Bulletin of the Bureau of Standards, Vol. 12, 1912, pp. 469–478.
- [5] Andrade C., Alonso C.: Corrosion rate monitoring in the laboratory and on site, Construction and Building Materials, Vol. 10, No. 5, 1996, pp. 315–328.
- [6] Millard S.: Measuring the corrosion rate of reinforced concrete using linear polarisation resistance, Concrete, 2003, pp. 36–38.
- [7] Gowers K., Millard S.: Electrochemical techniques for corrosion assessment of reinforced concrete structures, Proc. Institution Civil Engineers: Structures. & Buildings, Vol. 134, 1999, pp. 129–137.
- [8] Law D., Millard S., Bungey J.: Linear polarisation resistance measurements using a potentiostatically controlled guard ring, NDT&E International, Vol. 1, 2000, pp. 15–21.
- [9] Stern M., Geary A.: Electrochemical Polarization – Theoretical analysis of the shape of polarization curves, J. Electrochemical Society, Vol. 104, 1957, pp. 56–63.
- [10] Sadowski Ł.: Measurement of concrete resistivity for the assessment of corrosion risk, I International Interdisciplinary Technical Conference of Young Scientists, Poznan, 2008.
- [11] Sadowski Ł., Millard S.: Non-destructive assessment of the corrosion risk to reinforcing steel using a measurement of the resistance of concrete (in Polish), Przegląd Budowlany, Vol. 5, 2008, pp. 35–39.
Typ dokumentu
Bibliografia
Identyfikator YADDA