A comparison of two methods for assessment of lung mechanical parameters

Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Comparison tests of the added compliance method and the standard method for the assessment of mechanical parameters of respiratory system are presented in this paper. In the added compliance method, an additional external mechanical chamber as the added compliance is periodically connected to the respirator-lungs system, to determine the values of the mechanical parameters of the respiratory system. The software application for the system control and data acquisition is written in the LabView Environment. The results confirm that the added compliance method is sufficient to be used for the calculation of the total compliance of respiratory system during the artificial ventilation.
Twórcy
autor
  • Instytut Biocybernetyki i Inżynierii Biomedycznej PAN, Warszawa
Bibliografia
  • 1 Nunn J.F.: Applied Respiratory Physiology, London: Butterwoth & Co. Lid, 1977.
  • 2. Darowski M., Kozarski M.: The way of the measurement of the compliance and resistance of respiratory system, (in Polish), Lex-Pat, BPP/3518/1361/08 patent no. PL 194 694, 8, 2000.
  • 3. Darowski M., Pałko K.J., Jucha A., Kozarski M.: Expiratory pressure curve analysis for estimation of lungs mechanics. In: Lecture Notes of the ICB Seminars Assessment of mechanical support of heart and lungs, International Center of Biocybernetics, Warsaw, November 2001, 88-97.
  • 4. Darowski M., Pałko K. J., Jucha A., Kozarski M.: Expiratory pressure curve analysis for estimation of lungs mechanics. Biocybernetics and Biomedical Engineering, 2003, 23, l, 91-102.
  • 5. Barberis L., Manno E" Guerin C.: Effect of end-inspiratory pause duration on plateau pressure in mechanically ventilated patients. Intensive Care Med. 2003, 29, 130 134.
  • 6. Pałko K.J., Kozarski M., Darowski M.: Identification of Mechanical Parameters of Respiratory System during Ventilatory Support of Lungs, Biocybernetics and Biomedical Engineering 2005, 25, 1, 73-81.
  • 7. Pałko K.J. Rogalski A., Zieliński K., Glapiński J., Kozarski M., Pałko T,, Darowski M.: RC model-based comparison tests of the added compliance method with computer simulations and a standard method, Pol. J. Med. Phys. Eng. 2007, 13, 1, 13-21.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ3-0030-0039
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.