PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Vortex currents detected by stress MCGand fragmentation of ECG /MCG in VT patients

Identyfikatory
Warianty tytułu
PL
Prądy przedsionkowe wykrywane w wysiłkowym badaniu MKG i fragmentacja EKG/MKG u pacjentów z częstoskurczem komorowym
Języki publikacji
EN
Abstrakty
EN
The information content of electrocardiogram (ECG) and magnetocardiogram (MCG) is different. This is demonstrated by an investigation of the dependence of the signals on heart rate changes after physical exercise. For healthy volunteers the repolarization changes drastically in the MCG whereas no comparable changes are found in the ECG. A beat-to-beat analysis shows that in some cases an alternating T-wave is observed in the stress-MCG of healthy volunteers. The diagnostic value of both ECG and MCG for identifying patients at risk of ventricular tachycardia is demonstrated in three studies focusing on the depolarization phase of the signal.
PL
Informacja jaką zawiera elektrokardiogram (EKG) i magnetokardiogram (MKG) jest różna. Zostało to wykazane w badaniach zależności sygnałów od zmian częstości rytmu serca po wysiłku fizycznym. U zdrowych ochotników repolaryzacja zmienia się drastycznie w zapisie MKG, podczas gdy nie zostały znalezione porównywalne zmiany w EKG. Analiza beat-to-beat wykazuje, że w niektórych przypadkach obserwuje się zmieniony załamek T w wysiłkowym MKG u zdrowego ochotnika. Na podstawie trzech badań skupiających się na fazie depolaryzacji sygnału oszacowano wartość diagnostyczną zarówno EKG jak i MKG dla identyfikacji pacjentów zagrożonych częstoskurczem komorowym.
Twórcy
autor
autor
autor
autor
  • Physikalisch-Technische Bundesanstalt, Berlin, Germany
Bibliografia
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ3-0005-0040
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.