PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Circulatory assistance: basic classification of heart assistance methods and devices

Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This paper is focused on basic classification of mechanical circulatory assistance methods and devices regarding a way of their connection to the circulatory system (parallel, "in-series"), different manner of work (pulsatile, continuous-flow) or a goal of appliance (bridge to recovery, bridge to transplant, Total Artificial Heart). Also schematic layout of subjectively chosen assist devices are shown and discussed. The paper does not pretend to give an exhaustive description of mechanical circulatory assistance but rather evidence, after some brief historical remarks, the substance of the circulatory support itself.
Twórcy
  • Nałęcz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, ul. Ks. Trojdena 4, 02-109 Warsaw, Poland, krystyna.gorczynska@ibib.waw.pl
Bibliografia
  • 1. Pae W. E. Jr, Rosenberg G., Pierce W. S.: Ventricular Assistance: The Pennsylvania State University Experience. In: Unger F., Assisted circulation 3. Part II: Cardiac Assistance, London Paris Tokyo Hong Kong Berlin Heidelberg New York: Springer - Verlag 1989, 10, 115-131.
  • 2. Swartz M. T., Pennington D. G., McBride L. R. et al.: Temporary Mechanical Circulatory Support: Clinical Experience with 148 Patients, In: Unger F., Assisted circulation 3. Part II: Cardiac Assistance, London Paris Tokyo Hong Kong Berlin Heidelberg New York: Springer - Verlag 1989, 11, 132-151.
  • 3. Górczyńska K., Darowski M., Kozarski M.: Cardiovascular, Respiratory and Veno-Lymphatic Assistance. Modelling and Simulation. Biocybernetics and Biomedical Engineering, Warsaw, Publisher: PWN - Polish Scientific Publishers 2002, 22(2-3), 145-175.
  • 4. Reul H., Kaufmann R., Siess Th.: Cardiac Assist devices. In: Verdonck P, Intra and Extracorporeal Cardiovascular Fluid Dynamics. Nova Scotia. Canada: WITpress 1998, 8, 233-257.
  • 5. Samuels L., Entwistle J., Holmes E., Fitzpatrick J., Wechsler A.: Use of the AbioCor replacement heart as destination therapy for end-stage heart failure with irreversible pulmonary hypertension. J. Thorac. Cardiovasc. Surg. 2004, 128 (4), 643-645.
  • 6. Delgado R. M., Nawar M., Loghin C., Myers T. J., Gregoric I. D., Pool T. et al.: Catheterization of the AbioCorTM Implantable Replacement Heart. Evaluation of the Unique Physiology Created by the Device. Texas Heart Inst. J. 2006, 33 (3), 359-360.
  • 7. Balooki H. /Ed/.: Clinical Application of Intra-Aortic Balloon Pump. New York: Futura Publ. Comp. Inc. 1977.
  • 8. Dawling R. D., Etoch S. W., Stevens K. A., Johnson A. C., Gray L. A. Jr. et al.: Current Status of the AbioCor Implantable Replacement Heart. Annals of Thoracic Surg. 2001, 71, S147-S149.
  • 9. Schistek R.: Various Design of Nonpulsatile Blood Pumps. In: Unger F., Assisted circulation 3, Part II: Cardiac Assistance. London Paris Tokyo Hong Kong Berlin Heidelberg New York: Springer - Verlag: 1989, 20, 235-242.
  • 10. Olsen D. B.: The History of the Continuous-Flow Blood Pumps. Artif. Org. 2000, 24(6), 401-404.
  • 11. Pagani F. D.: Continuous-Flow Rotary Left Ventricular Assist Device with 3rd Generation Design. Elsevier: Seminars in Thoracic and Cardiovasc. Surg. 2008, 20(3), 255-263.
  • 12. Frazier O. H., Gemmato C., Myers T. J., Gregoric I. D. B., Loyalka P, Kar B.: Initial Clinical Experience with the HeartMate II Axial-Flow Left Ventricular Assist Device. Tex. Heart Inst. 2007, 34(3), 275-281.
  • 13. Loforte A., Montalto A., Ranocchi F., Casali G., Luzi G. et al.: HeartMate II axial-flow left ventricular assist system: management, clinical review and personal experience. Inst. Cardiovasc. Medicine 2009, 10(10), 765-771.
  • 14. Wieselthaler G. M., Schima H., Hiesmayr M., Pacher R., Laufer G., Noon G. P. et al.: First Clinical Experience With de Bakey Vad Continuous-Axial-Flow Pump for Bridge to Transplantation. Circulation 2000, 101, 356-359.
  • 15. Goldstein D. J., Zucker M., Arroyo L., Baran D., McCarthy P. M., Loebe M. et al.: Safety and feasibility trial of the MicroMed de Bakey ventricular assist device as a bridge to transplantation. Am. Coll. Cardiol. 2005, 45, 962-963.
  • 16. Palino M. A., Ohye R. C., Chang A. C., Gajarski R. J., Bove E. L., Devaney E. J.: Bridge to Transplant Using the MicroMed DeBakey Ventricular Assist Device in a Child with Idiopatic Dilated Cardiomyopathy. Annals Thorac. Surg. 2006, 81(3), 1118-1121.
  • 17. Kőrfer R., El-Banayosy A., Posival H., Minami K., Kizner L., Arusoglu L., Michael M., Korner M.M.: Mechanical Circulatory Support With the Thoratec Assist Device in Patients with Postcardiotomy Cardiogenic Shock. Ann. Thorac. Surg. 1996, 61, 314-316.
  • 18. Farrar D. J.: The thoratec ventricular assist device: a paracorporeal pump for treating acute and chronic heart failure. Semin. Thorac. Cardiovasc. Surg. Jul 2000, 12(3), 243-250.
  • 19. Farrar D. J., Hill J. D., Pennington D. G., McBride L. R., Holman W. L., Kormos R. L. et al.: Preoperative and postoperative comparison of patients with univentricular and biventricular support with the Thoratec ventricular assist device as a bridge to cardiac transplantation. J. Thorac. Cardiovasc. Surg. 1997, 113, 202-209.
  • 20. Deleuze P. H., Le Besnerais P., Mazzucotelli J. P., Abe Y. et al.: Use of the Nippon-Zeon Pneumatic Ventricular Assist Device as a Bridge to Cardiac Transplantation. ASAIO J. 1994, 40(3), M325-M328.
  • 21. Takano H., Nakatani T.: Ventricular Assist Systems: Experience in Japan with Toyobo Pump and Zeon Pump, Ann. Thorac. Surg., 1996, 61, 317-322.
  • 22. Dunnington G. H, Sleasman J., Alkhaldi A., Pellentier M. P., Reitz B. A., Robbing R. C.: Successful Bridge to Transplant Using the Berlin Heart Left Ventricular Assist Device in a 3 Month-Old Infant. Ann. Thorac. Surg. 2006, 81, 1116-1118.
  • 23. Baird N. M., Fyn-Thomson F., Almend C., Thiagarajan R., Laussen P., Blume E., Pigula F.: Successful implantation of a Berlin heart left ventricular assist device in a failing left ventricle, J. Thorac. Cardiovasc. Surg. 2006, 131 (6), 1407-1408.
  • 24. Kawaguchi O., Pue W. E., Daily B. B., Pierce W. S.: Ventriculoarterial coupling with intra-aortic balloon pump in acute ischemic heart failure. J. Thorac. Cardiovasc. Surg. 1999, 117(1), 164-171.
  • 25. Sauren L. D., Reesink K. D., Selder J. L., Beghi C., van der Veen F. H., Maessen J. G.: The acute effect of intra-aortic balloon counterpulsation during extracorporeal life support: an experimental study. Artif. Organs 2007, 31(1), 31-38.
  • 26. Bian X., Downy H. S.: Enhanced Intra-Aortic Balloon Pump: Markedly Improved Systemic Hemodynamics and Cardiac Function in Canines with Severe, Acute Left Ventricular Failure. Artif. Organs 2002, 26(8), 727-733.
  • 27. Ntalianis A. S., Drakos S. G., Charitos C., Dolou P., Pierrakos C. N., Terrovitis J. V. et al.: Effects of intra-aortic balloon pump versus centrifugal pump on myocardial energetics and systemic circulation in a porcine model of rapidly worsening acute heart failure. ASAIO J. 2008, 54(6), 600-605.
  • 28. Olasińska-Wiśniewska A., Mularek-Kubzdela T., Grajek S., Breborowicz P., Seniuk W., Podzerek T.: Indications, results of therapy and factors which influence survival in patients treated with intra-aortic balloon counterpulsation. Kardiol. Pol. 2008, 66(9), 950-55, disc. 956-957.
  • 29. Onorati F., Santarpino G., Rubino A. S., Caroleo S., Dardano A., Scalas C., Gulletta E., Santangelo E., Renzulli A.: Body perfusion during adult cardiopulmonary bypass is improved by pulsatile flow with intra-aortic balloon pump. Int. J. Artif. Organs 2009, 32(1), 50-61.
  • 30. Jaron D., Moore T. W., He P.: Theoretical considerations regarding the optimisation of cardiac assistance by intra-aortic balloon pumping. IEEE Trans. Biomed. Eng. 1983, 30(3), 177-186.
  • 31. Khir A. W., Price S., Hale C., Young D. A., Parker K. H., Pepper JR.: Intra-aortic balloon pumping: does posture matter? Artif. Organs 2005, 29(1), 36-40.
  • 32. Frazier O. H., Myers T. J., Radovancević B.: The HeartMate Left Ventricular Assist System. Overview and 12-Year Experience, Texas Heart Inst. J. 1998, 25, 265-271.
  • 33. Ferrari G., Darowski M., Gólczewski T., Górczyńska K., Kozarski M.: Comprehensive models of cardiovascular and respiratory systems: Chapter 1. Introduction to Circulatory and Respiratory System Modeling, Nova Science Publishers, Inc. New York 2010, 1-38.
  • 34. Nanas J. N., Moulopoulos S. D.: Counterpulsation: Historical Background, Technical Improvements, Hemodynamic and Metabolic Effects. Cardiology 1994, 84(3), 156-167.
  • 35. Zheng Z. S,. Li T. M., Kambic H., Chen G. H., Yu L. Q., Cai S. R. et al.: Sequential external counterpulsation (SECP) in China. Trans. Am. Soc. Artif. Intern. Organs. 1983, 29, 599-603.
  • 36. Applebaum R. M., Kasliwal R., Tunick P. A., Konecky N., Katz E. S., Trehan N., Kronzon I.: Sequential external counterpulsation increases cerebral and renal blood flow. Am. Heart J. 1997, 133(6), 611-615.
  • 37. Ochoa A. B., de Jong A., Grayson D., Franklin B., McCullough P.: Effect of enhanced external counterpulsation on resting oxygen uptake in patients having previous coronary revascularization and in healthy volunteers. Am. J. Cardiol. 2006, 1998, 613-615.
  • 38. Nichols W.W., Estrada J.C., Braith R.W., Owens K., Conti CR.: Enhanced external counterpulsation treatment improves arterial wall properties and wave reflection characteristics in patients with refractory angina. J. Am. Coll. Cardiol. 2006, 48, 1208-1214.
  • 39. Erdling A., Bondesson S., Pettersson T., Edvinsson L.: Enhanced external counter pulsation in treatment of refractory angina pectoris: two year outcome and baseline factors associated with treatment failure. BMC Cardiovasc. Disorder 2008, 8 (39), 1-7.
  • 40. Nakatani S., Thomas J. D., Savage R. M., Vargo R. L., Smedira N. G., McCarthy P. M.: Prediction of Wright Ventricular Dysfunction After Left Ventricular Assist Device Implantation. Circulation, Supplement II 1996, 94 (9), II216-II221.
  • 41. Park C. Y., Park J. W., Lee J. J., Kim W. E., Hwang C. M., Om K.-S., Choi J. et al.: Development of Totally Implantable Pulsatile Biventricular Assist Device. Artificial Orrgans. Blackwell Publ. Inc. 2003, 27 (1), 119-123.
  • 42. Górczyńska K., Ferrari G., De Lazzari C., Mimmo R., Tosti G., Clemente F., Englisz M., Guaragno M.: The Influence of Selected Left Ventricular and Systemic Parameters on Cardiovascular Hemodynamics and Energetics - Modelling Study. BBE 2000, 20 (3), 35-48.
  • 43. Ferrari G., Górczyńska K., Mimmo R., De Lazzari C., Clemente F., Tosti G. et al.: Mono and biventricular assistance: their effect on ventricular energetics. Int. J. Artif. Organs 2001, 6(24), 380-391.
  • 44. Ono M.: Heart Assist Devices: statistics and numerical data. Masui 2009, 58(3), 327-336.
  • 45. Endo G., Araki K., Oshikawa M., Kojima K., Saitoh T., Nsakamura K. et al.: Control Strategy for Biventricular Assistance with Mixed-Flow Pumps. Artif. Organs. 2000, 8(24), 594-599.
  • 46. Forrester M. D., Myers T. J., Gregoric I. D., Frazier O. H.: Saphenous Vein Graft Flow during Left Ventricular Assistance with an Axial Flow Pump. Tex. Heart Inst. J. 2006, 33 (2), 222-224.
  • 47. Arabia F. A., Copeland J. G, Smith R. G., Banchy M., Foy B., Kormos R., Tector A., Long J. et al.: CardioWest Total Artificial Heart: A Retrospective Controlled Study. J. Artif.Org. 1999, 23 (2), 204-207.
  • 48. Copeland J. G., Arabia F. A., Smith R. G., Sethi G. K., Nolan P. E., Banchy M. E.: Arizona experience with CardioWest total artificial heart bridge to transplantation. Ann. Thorac. Surg. 1999, 68, 756-760.
  • 49. Copeland J. G., Smith R. G., Arabia F. A., Nolan P. E., Sethi G. K., Tsau P. H., Mc Clellan D., Slepian M. J.: Cardiac Replacement with a Total Artificial Heart as a Bridge to Transplantation. New Eng. J. Med. 2004, 351(9), 859-867.
  • 50. Leshnower B. G., Smith R. G., O'Hara M. L., Woo Y. J., et al.: Is the Total Artificial Heart Superior to BIVAD Therapy as a Method of Bridging Patients to Heart Transplantation?. 43rd Ann. Meeting Soc. Thorac. Surg. (STS). Jan. 2007.
  • 51. Watson J. T.: Implantable Artificial Heart Systems. In Akutsu T, Koyanagi H. Artificial Heart 5.Springer-Verlag, Tokyo 1996, 95-100.
  • 52. Santamore W. P., Gray J. A. Jr.: Left Ventricular Contributions to Right Ventricular Systolic Function during LVAD Support. Ann. Thorac. Surg. 1996, 350-356.
  • 53. Reul H., Kaufmann R., Siess Th.: Cardiac Assist devices. In: Verdonck P, Intra and Extracorporeal Cardiovascular Fluid Dynamics. Nova Scotia. Canada: WITpress 1998, 8, 245-249.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ1-0069-0001
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.