Influence of spheroidal cast iron wall thickness on its microstructure and ultrasonic control index

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This work presents results of ultrasonic evaluation of the microstructure of spheroidal cast iron manufactured under production conditions. Evaluation of the ultrasonic control index's sensitiveness to changes in microstructure (graphite shape index Ss and average number of graphite precipitations NA) of cast iron, was made on modelled stepped castings. A relation between the graphite precipitation shape index Ss and the velocity of longitudinal ultrasonic wave cL has been defined, as well as a relation between the average number of graphite precipitations NA and the velocity of longitudinal ultrasonic wave cL.
Rocznik
Strony
125--128
Opis fizyczny
Bibliogr. 6 poz., rys., tab., wykr.
Twórcy
autor
autor
autor
autor
autor
autor
autor
  • Department of Casting and Welding Technical University of Rzeszow, 35-959 Rzeszów, ul. W. Pola 2
Bibliografia
  • [1]Orłowicz W.: Zastosowanie ultradźwięków w odlewnictwie. Krzepnięcie metali i stopów. PAN Katowice, 2000, vol. 2, No 45.
  • [2] Paterrson B. R., Batters C. E.: Nondestructive property prediction in gray cast iron using ultrasonic technique. AFS Transactions, vol. 89, No 65, 1981, 369-378.
  • [3] Kovacs B. V.: Quality control and assurance by sonic resonance in ductile iron castings. AFS Transactions, vol. 85, No 76, 1977, 499-508.
  • [4] Emerson P. J., Simmonson W.: Final report on the evaluation of the graphite form in ferritic ductile iron by ultrasonic and sonic testing and of the effect of graphite form on mechanical properties AFS Transactions, vol. 84, No 26, 1976, 109-128.
  • [5] Guo X.: A statistical study on the relationship between tensile strength and ultrasonic velocity of cast iron. International Journal of Cast Metals Research, 2003, vol 16, 221-226.
  • [6] Orłowicz W., Opiekun Z., Gedeonowa Z., Tresa D.: Wpływ warunków ulepszania cieplnego żeliwa sferoidalnego na wartość wskaźników kontroli ultradźwiękowej. 23 Krajowa Konferencja Badań Nieniszczących, 1994, s. 89-96.