PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The assessment of biocompatibility of systems consisting of a host, permiselective membrane and a biological material, encapsulated within may be standardized for biological material immunoisolation purposes. The procedures for evaluation of the membrane non-toxicity against the biological material, the membrane physical and chemical stability post implantation and the biomaterial ability to perform with the host are presented.
Twórcy
autor
autor
autor
  • Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, ul. Ks. Trojdena 4, 02-109 Warsaw, Poland, ludomira@ibib.waw.pl
Bibliografia
  • 1. Wiliams D.F.: Summary and Definitions, in: Progress in Biomedical Engineering: Definition in Biomaterials (4), Elsevier, Amsterdam, 1987, 66-71.
  • 2. Soon Shiong P., Otterlei M., Skjak-Brek G., Smidsrod O., Heintz R., Lanza R.P., Espevik T.: An immunological basis for fibrotic reaction to implanted microcapsules. Transplant. Proc. 1991, 23, 758-759.
  • 3. Rihova B.: Biocopatibility of biomaterials: hemocompatibility, immunocompatibility and biocompatibility of solid polymeric materials and soluble targetable polymeric carriers. Adv. Drug Deliv. Rev. 1996, 21, 157-176.
  • 4. Babensee J.E., Anderson J.M., McIntire L.V., Micos A.G.: Host response to tissue engineered devices. Adv. Drug Deliv. Rev. 1998, 33, 111-139.
  • 5. Clark H., Barbari T.A., Stump K., Rao G.: Histologic evaluation of the inflammatory responses around implanted hollow fiber membranes. J. Biomed. Mater. Res. 2000, 52, 183-92.
  • 6. Huang T.H., Yang J.J., Li H., Kao C.T.: The biocompatibility evaluation of epoxy resin-based root canal sealers in vitro. Biomaterials, 2002, 23(1), 77-83.
  • 7. Sefton M.V., Gemmel C.H., Gorbet M.B.: Whal really is blood compatibility? J. Biomater. Sci. Polymer Edn, 2000, 11(11), 1165-1182.
  • 8. Zhang Q., Wang C.R., Babukutty Y., Ohyama T., Kogoma M., Kodama M.: Biocompatibility evaluation of ePTFE membrane modified with PEG in atmospheric pressure glow discharge. J. Biomed. Mater. Res., 2002, 60(3), 502-509.
  • 9. Desanctis L.B., Stefoni S., Cianciolo G., Coli L., Buscaroli A., Feliciangeli G., Borgnino L.C., Bonetti M., Gregorini M.C., DeGiovanni P., Buttazzzi R.: Effect of different dialysis membranes on platelet function. A tool for biocompatibility evaluation. Int. J. Artif. Organs, 1996, 19(7), 404-410.
  • 10. Nageswari K., Banerjee R., Gupte R.V., Puniyani R.R.: Hemorheological parameters for biocompatibility evaluation. J. Biomater. Appl., 1998, 13(1), 74-80.
  • 11. Pariente J.L., Bordenave L., Bareille R., Rouais F., Courtes C., Daude G., le Guillou M., Baquey C.: First use of cultured human urothelial cells for biocompatibility assessment: Application to urinary catheters. J. Biomed. Mater. Res., 1998, 40(1), 31-39.
  • 12. Pariente J.L., Kim B.S., Atala A.: In vitro biocompatibility evaluation of naturally derived and synthetic biomaterials using normal human bladder smooth muscle cells. J. Urology, 2002, 167(4), 1867-1871.
  • 13. Roy S., Fleischman A.J.: Cytotoxicity evaluation of Microsystems materials using human cells. Sensors&Biomaterials, 2003, 15(6), 335-340.
  • 14. Granicka L.H., Wojciechowski C., Chwojnowski A., Jankowska E., Wdowiak M., Świeżewski S., Kosek A., Kawiak J.: The biocompatibility of membranes for immunoisolation. membrane cytotoxity evaluation. Permea 2005, Membrane Science and Technology Conference of Visegrad Countries, (pg.16 abstract), artykuł w materiałach konferencyjnych na płycie CD, nr AMAM-P05.
  • 15. Granicka L., Weryński A., Kawiak J.: Membrane for immunoisolation: Properties before and post implantation, preliminary report. Artificial Cells, Blood Substitutes and Immobilization Biotechnology. 2004, 32(4), 1-10.
  • 16. Granicka L.: Bioenkapsulacja dla celów biomedycznych. Prace IBIB, 2006, Nr 67.
  • 17. Clark H., Barbari T.A., Stump K., Rao G.: Histologic evaluation of the inflammatory responses around implanted hollow fiber membranes. J. Biomed. Mater. Res., 2000, 52, 183-192.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ1-0045-0014
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.