Tytuł artykułu
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
Aortofemoral prosthetic Y grafts are applied for treating abdominal aortic aneurysms. In this study, experiments were conducted in order to demonstrate the effects of an incremental increase in branch diameter in a newly designed aortofemoral Y graft under conditions of both steady and pulsatile flow conditions. It was revealed that in Y grafts, the incremental increase by only 4 mm in the branch diameter affects hydrodynamic characteristics drastically under conditions of both steady and pulsatile flow conditions.
Wydawca
Czasopismo
Rocznik
Tom
Strony
59--63
Opis fizyczny
Bibliogr. 2 poz., rys., wykr.
Twórcy
autor
autor
autor
autor
autor
autor
- Departament of Mechanical Engineering, Shibaura Institute of Technology, Tokyo, Japan, fujimoto@sic.shibaura-it.ac.jp
Bibliografia
- 1. Fujimoto T., Ohashi H., Arai K., Okamoto K., Iwamura H., Shiraishi Y., Umezu M.: Effect of bifurcation on pressure loss in aortofemoral prosthetic Y grafts, Int. J. Artif. Organs., 2003, 26(7), 629.
- 2. Fujimoto T., Nakano S., Iwamura H., Shiraishi Y., Yambe T., Umezu M.: Characteristics of a newly designed aortofemoral prosthetic Y graft under pulsatile flow conditions, Int. J. Artif. Organs. 2006, 29(5), 546.