Tytuł artykułu
Autorzy
Shiraishi Y.
Yambe T.
Sekine K.
Ogawa D.
Nagatoshi J.
Itoh S.
Park Y.
Uematsu M.
Sakata R.
Wada Y.
Saijo Y.
Higa M.
Hori Y.
Liu H.
Wang Q.
Konno S.
Kuwayama T.
Olegario P.
Tanaka A.
Masumoto N.
Ibuki R.
Maruyama S.
Okamoto E.
Fujimoto T.
Yoshizawa M.
Umezu M.
Imachi K.
Nitta S.-I.
Sasada H.
Tabayashi K.
Homma D.
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
Recently, the ventricular assist devices are widely applied for a surgical treatment of the final stage of severe heart failure as the bridge to heart transplantation or the destination therapy. However, it was anticipated that the artificial components in the ventricular assist devices might cause the problems concerning thrombosis and infection. As heart failure involves the decrease in myocardial contractile function, the mechanical assistance by using an artificial myocardium might be effective. In this study, the authors developed a mechano-electric artificial myocardial assist system (artificial myocardium), which is capable of supporting natural contractile function from the outside of the ventricle.
Wydawca
Czasopismo
Rocznik
Tom
Strony
147--154
Opis fizyczny
Bibliogr. 17 poz., fot., rys., wykr.
Twórcy
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
- Institute of Development, Aging and Cancer, Tohoku University, Sendai 980-8575, Japan, shiraishi@idac.tohoku.ac.jp
Bibliografia
- 1. Hosenpud J.D., et al.: The registry of the international society for heart and lung transplantation: fifteenth official report-1998, J. Heart Lung Transplant., 1998, 17, 656-668.
- 2. Shimizu T., et al.: Fabrication of pulsatile cardiac tissue grafts using a novel 3-dimensional cell sheet manipulation technique and temperature-responsive cell culture surfaces, Circ. Res., 2002, 90(3), e40.
- 3. Nitta S., et al.: Application of shape memory alloy for an artificial heart driving system, MBE 1983, 83^9, 45-51 (in Japanese).
- 4. Yambe T, et al.: Addition of rhythm to non-pulsatile circulation, Biomed. Pharmacother., 2004, 58, Suppl. 1,8145-9.
- 5. Yambe T., et al.: Artificial myocardium with an artificial baroreflex system using nano technology, Biomed. Pharmacother., 2004, 57 Suppl. 1, 122-125.
- 6. Wang Q., et al.: An artificial myocardium assist system: electrohydraulic ventricular actuation improves myocardial tissue perfusion in goats, Artif. Organs, 2004, 28(9), 853-857.
- 7. Andtadt G.L., et al.: A new instrument for prolonged mechanical massage, Circulation, 1965, 31 (Suppl. II), 43.
- 8. Anstadt M., et al.: Direct mechanical ventricular actruator, Resuscitation, 1991, 21, 7-23.
- 9. Kawaguchi O., et al.: Dynamic cardiac compression improves contractile efficiency of the heart, J. Thorac. Cardiovasc. Surg., 1997, 113, 923-931.
- 10. Buehler W.J., Gilfrich J., Wiley K.C.: Effect of low-temperature phase changes on the mechanical properties of alloys near composition TiNi, J. Appl. Phys., 1963, 34, 1465.
- 11. Homma D., Miwa Y, Iguchi N., et al.: Shape memory effect in Ti-Ni alloy during rapid heating, Proc. of 25th Japan Congress on Materials Research, 1982.
- 12. Sawyer P.N., et al.: Further study of NITINOL wire as contrctile artificial muscle for an artificial heart, Carrdiovasc. Diseases Bull. Texas Heart Inst, 1976, 3, 65.
- 13. Westerby S.: Non-transplant surgery for heart failure, Heart, 83, 2000, 603-610.
- 14. Suma H., et al.: Non transplant cardiac surgery for end-stage cardiomyopathy, J. Thorac. Cardiovasc. Surg., 2000, 119,1233-1244.
- 15. Raman J.S., et al.: The mid-term results of ventricular containment (Acorn Wrap) for end-stage ischemic cardiomyopathy, 2005.
- 16. Pilla J.J., et al.: Ventricular constraint using the cardiac support device reduces myocardial akinetic area in an ovine model of acute infarction, Circulation, 2002,106 [Suppl 1], 1207-1211.
- 17. Uematsu M., Shiraishi Y, et al. Proc. IEEE-EMBS, 2005.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ1-0043-0017