The fIow interrupter technique is an attractive method of respiratory mechanics measurement. Lack of reliable algorithms for processing of the data measured as well as a low level of the routine informativity schemes disqualify the method as a useful tool in clinical and diagnostic practice. The theoretical basis of the enhanced interrupter technique (EIT) prepared by the authors is a chance to change the role of the technique in the set of available measurement methods. In the report, computer investigations showing an advantage of EIT over the most popular methods of the postocclusional data analysis, characterised in literature, are presented. Beside the evidence of an improvement of the basic algorithm informativity, also an increased accuracy of the results in the simulation experiment organised by the authors has been shown.
Twórcy
autor
  • Wrocław University of Technology, Department of Electronics, Chair of Electronic and Photonic Metrology, ul. B. Prusa 53/55, 50-317 Wrocław, Poland, ireneusz.jablonski@pwr.wroc.pl
Bibliografia
  • 1. Neergaard J. von, Wirz K.: Die Messung der Strömungswiderstäde in den Atemwegen des Menschen, insbesondere bei Astma und Emphysem. Z. Klin. Med. 1927, 105, 51-82.
  • 2. Mead J., Whittenberger J.L.: Evaluation of airway interruption technique as a method for measuring pulmonary air-flow resistance. J. Appl. Physiol. 1954, 6, 408-416.
  • 3. Jackson A.C., Milhorn H.T. Jr., Norman J.R.: A reevaluation of the interrupter technique for airway resistance measurement. J. Appl. Physiol., 1974, 36, 264-268.
  • 4. Bates J.H.T., Ludwig M.S., Sly P.D., Brown K., Martin J.G., Fredberg J.J.: Interrupter resistance elucidated by alveolar pressure measurements in open-chest normal dogs. J. Appl. Physiol., 1998, 65, 408-414.
  • 5. Bates J.H.T., Baconnier P., Milic-Emili J.: A theoretical analysis of interrupter technique for measuring respiratory mechanics. J. Appl. Physiol., 1988, 64, 2204-2214.
  • 6. Van der Plas K., Vooren P.: The opening interruptor: a new wariant of a technique for measuring respiratory resistance. Eur. J. Respir. Dis., 1982, 63, 449-458.
  • 7. Frey U., Kraemer R.: Oscillatory pressure transients after flow interruption during bronchial challenge test in children. Eur. Respir. J., 1997, 10, 75-81.
  • 8. Wirz Sommer C., Frey U., Schöni H.M., Kraemer R.: Specific approach on dose-response curves to inhaled carbachol assessed by the interruption technique in children. Pediatr. Res., 1993, 34, 478-484.
  • 9. Bates J.H.T., Abe T., Romero P.V., Sato J.: Measurement of alveolar pressure in closed-chest dogs during flow interruption. J. Appl. Physiol., 1989, 67, 488-492.
  • 10. Bates J.H.T., Brown K., Kochi T.: Identyfying a model of respiratory mechanics using the interrupter technique. IEEE Proc. Annu. Conf. Eng. Med. Biol. Soc. 9th Boston, 1987, 1802-1803.
  • 11. Bates J.H.T., Sly P.D., Okubo S.: General method for decribing and extrapolating monotonic transients and its application to respiratory mechanics. Med. Biol. Eng. Comput., 1987, 25, 131-135.
  • 12. Sly P.D., Brown K.A., Bates J.H.T., Macklem P.T., Milic-Emili J., Martin J.G.: Effects of lung volume on interrupter resistance in cats challenged with methacholine. J. Appl. Physiol., 1988, 64, 360-366.
  • 13. Jabłoński I., Polak A.G., Mroczka J.: Methods of identification of a model for the respiratory system during airflow interruption (in Polish). Measurements Automatics Control, 2000, 8, 18-22.
  • 14. Jabłoński I., Polak A.G., Mroczka J.: Effect of flow interruption duration on precision of respiratory system parameters estimation (in Polish). III Symposium on "Modelling and Measurements in Medicine" Krynica Górska, 7-11 May 2001, 53-61.
  • 15. Jabłoński I., Mroczka J.: Linear model for the respiratory system during airflow interruption (in Polish). Measurements Automatics Control, 2002, 10, 18-22.
  • 16. Jabłoński I., Mroczka J.: Respiration mechanics evaluation in reduced model of the system for interrupter technique (in Polish). V Symposium on "Modelling and Measurements in Medicine", Krynica Górska, 12-15 May 2003, 73-78.
  • 17. Jabłoński I., Mroczka J.: Metrological analysis of the interrupter technique in investigations of the respiratory system properties (in Polish). Proceedings of "Congress of Metrology", 6-9 September 2004, V. 2, 595-598.
  • 18. Phagoo S.B., Wilson N.M., Silverman M.: Evaluation of a new interrupter device for measuring bronchial responsiveness and response to bronchodilator in 3 year old children. Eur. Respir. J., 1996, 9, 1374-1380.
  • 19. Vuilleumier P.: Über eine Methode zur Messung des intraalveolären Drukes und der Strömungswiderstünde in den Atemwegen des Menschen. Z. Klin. Med., 1944, 143, 698.
  • 20. Frey U., Schibler A., Kraemer R.: Pressure oscillations after flow interruption in relation to lung mechanics. Respir. Physiol., 1995, 102, 225-237.
  • 21. Polak A.G., Mroczka J.: Non-invasive techniques of measurement of the respiratory system mechanical properties (in Polish). Metrologia i Systemy Pomiarowe, 1999, 6, 75-95.
  • 22. Liistro G., Stănescu D., Rodenstein D., Veriter C.: Reassessment of the interruption technique for measuring flow resistance in humans. J. Appl. Physiol., 1989, 67, 933-937.
  • 23. Bates J.H.T., Daróczy B., Hantos Z.: A comparison of interrupter and forced oscillation measurements of respiratory resistance in dog. J. Appl. Physiol., 1992, 72, 46-52.
  • 24. Jabłoński I., Mroczka J.: Usefulness evaluation of interrupter technique for measurement of nonlinear characteristics of the respiratory system (in Polish). VI Symposium on "Modelling and Measurements in Medicine", Krynica Górska, 9-13 May 2004, 57-66.
  • 25. Lorino H., Mariette C., Lorino A.M.: Comparison of standard and unbiased estimators of respiratory impedance. Eur. Respir. Rev., 1994, 4, 130-134.
  • 26. Lutchen K.R.: Sensitivity analysis of respiratory parameters uncertainties: impact of criterion form and constraints. J. Appl. Physiol., 1990, 69, 766-775.
  • 27. Lutchen K.R., Jackson A.C.: Confidence bounds on respiratory mechanical properties estimated from transfer versus input impedance in humans versus dogs. IEEE Trans. Biomed. Eng., 1992, 39, 644-651.
  • 28. Polak A.G.: Indirect measurements: combining parameter selection with ridge regression. Meas. Sci. Technol., 2001, 12, 278-281.
  • 29. Romero P.V., Sato J., Shardonofsky F., Bates J.H.T.: High frequency characteristics of respiratory mechanics determined by flow interruption. J. Appl. Physiol., 1990, 69, 1682-1688.
  • 30. Gappa M., Colin A.A., Goetz I., Stocks J.: Passive respiratory mechanics: the occlusion techniques. Eur. Respir. J., 2001, 17, 141-148.
  • 31. Golden J.F., Clark J.W., Stevens P.M.: Mathematical modelling of pulmonary airway dynamics. IEEE Trans. Biomed. Eng., 1973, 20, 397-404.
  • 32. Ginzburg I., Elad D.: Dynamic model of the bronchial tree. J. Biomed. Eng., 1993, 15, 283-288.
  • 33. Lambert R.K.: Sensitivity and specificity of the computational model for maximal expiratory flow. J. Appl. Physiol.: Respirat. Environ. Exercise Physiol., 1984, 57, 958-970.
  • 34. Lambert R.K., Wilson. T.A., Hyatt R.E., Rodarte J.R.: A computational model for expiratory flow. J. Appl. Physiol.: Respirat. Environ. Exercise Physiol., 1982, 52, 44-56.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ1-0030-0020
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.