Many studies concerning evaluation of the artery blood flow based on coronarographic images have been made. Application of the indicator-dilution technique allows calculation of absolute values of the blood flow in the coronary arteries based on the densitometric analysis of coronarographic image sequences under some specific conditions imposed on injections of the contrast medium and digital image sequences registration. This method is based on densitometric measurements carried out in two sequences of images of the same artery. The first sequence is recorded during the routine injection of the contrast, and the other is recorded during the slow test injection of the contrast with a reduced amount of the indicator. The method was tested on coronarographic images obtained in routine examinations in two groups of control patients. The comparative analysis of 18 patients indicates that there exists a moderate consistency between the results of this method and the clinical assessment. The results of our studies are strongly dependent on the accuracy of the measurements and the method of recording. Proposed method, tested on the model of artery and measurements obtained from coronarographic examinations of control groups of patients, provides grounds for future studies.
Twórcy
autor
autor
  • Institute of Biocybernetics and Engineering, Polish Academy of Sciences, Trojdena 4, 02-129 Warsaw, Poland, hania@ibib.waw.pl
Bibliografia
  • 1. Nissen S.E. and Gurley J.C.: Aplication of indicator dilution principles to regional assessment of coronary flow reserve from digital angiography, Quantitative Coronary Angiography, ed. Reiber J.H.C and Serruys P.W., vol. 117, Kluver Academic Publishers, 1991, 245-263.
  • 2. Schelbert M., Wolf S.: Cardiac imaging, ed. By M. Marcus et al., W. Saunders Company, 1991.
  • 3. Górecka B., Dzielińska Z., Dernałowicz J., Goszczyńska H., Jodkowski J., Kulikowski J., Dąbrowski M., Rużyłło W.: A new method of computer analysis of conventional coronary flow measurement. European Heart Journal, 1994, 15, 165.
  • 4. Dernałowicz J., Dzielińska Z., Goszczyńska H., Górecka B.: Multivariable approach to the global coronary blood flow evaluation, Biocybernetics and Biomedical Engineering, PWN, Warsaw, 1996, 15, 3-4, 27-35.
  • 5. Dorsaz P.A., Doriot P.A., Dorsaz L., Chatelain P., Rutishauser W.: A new densitometric approach to the assessment of mean coronary flow, Invest. Radiology 1997, 32(4), 198-204.
  • 6. Schrijver M.: Angiographic Image Analysis to Assess the Severity of Coronary Stenoses, Twente University Press, Enschede, Netherlande, 2002.
  • 7. Dernałowicz J., Goszczyńska H., Collorec R., Purzycki Z., Leszczyński L.: Theoretical and Practical Aspects of the Volumetric Global Coronary Blood Flow Measurements from One-Plane Coronarographic Images, Polish J. Med. Phys. & Eng. 1998, PTFM, Warsaw, 4(14), 183-194.
  • 8. Goszczyńska H.: Computer analysis of coronarographic images for coronary flow estimation (in polish), Biomedical Imaging 2003, in Nałęcz M. (Ed.): Biocybernetics and Biomedical Engineering, (PAS , Warsaw), 8, 373-416.
  • 9. Cusma J.T. et al.: Digital angiographic imaging of coronary flow reserve, Circulation, 75, 2, 1987.
  • 10. Goszczyńska H., J. Dernałowicz: Correction of the physical and technical factors leading to deterioration in densitometric measurements performed on coronarographic films, Polish J. Med. Phys.& Eng. 2000, 6, 2, 91-100.
  • 11. Dernałowicz J., Goszczyńska H., Mazur P.: Evaluation of indicator-dilution process in X-ray angiographic images deteriorated by factors of technical origin, Polish J. Med. Phys&Eng. 1996, 2, 163-175.
  • 12. Rong J.H.: Estimation and characteristic of the movement in coronary angiography (in French), Doctoral Thesis, University of Rennes I, Rennes, France 1989.
  • 13. Goszczyńska H.: Computer analysis of coronarographic images for coronary flow calculation (in Polish), Doctoral Thesis, Institute of Biocybernetics and Biomedical Engineering PAS, Warsaw 2004.
  • 14. Goszczyńska H., Bogorodzki P., Wolak T., Kurjata R., Orzechowski M.: Coronary Blood Flow Measurement from X-Rays Images - Experiment Performed on the Artery Model, SPIE Proceedings 2004, 5505, 157-163.
  • 15. Hofman M.B.M., Wickline S.A., Lorenz C.H.: Quantification of In-Plane Motion of the Coronary Arteries During the Cardiac Cycle: Implications for Acquisition Window Duration for MR Flow Quantification, JMRI 1998, 8, 568-576.
  • 16. Simon R., Herrmann G. and Amende I.: Comparison of three different principles in the assessment of coronary flow reserve from digital angiograms, Int. J. Card. Imaging 1990, 5 (2-3), 203-212.
  • 17. Horszczaruk G.J., Kochman J., Gil R., Dudek D., Opolski G.: Angiographic estimation of the coronary flow - is it enough just a bird's eye view? (in Polish), Folia Cardiol., 9(4), 2002, 293-301.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ1-0030-0016
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.