PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Hydroxyapatite coated dental implants by sputtering technique

Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Hydroxyapatite (HA) was coated onto titanium substrates using radio frequency sputtering, and the coated HA films were crystallized in autocIave at 110°C using the low temperature hydtrothermal method. In pull-out tests, the adhesion strength of the sputtered film to the substrate increased from 1.9 : 0.2 to 5.3 : 1.6 MPa after the hydrothermal treatment. Sputtered films subjected to the hydrothermal treatment and plasma-sprayed coating on titanium columns were implanted in the diaphysis of the femora of six adult dogs, and pull-out tests were carried out after two, four, and 12 weeks. The sputtered film showed a higher bone bonding strength than the plasma-sprayed coating at the same periods. The coated implants were also placed into mandibles for 2,4, 12 and 24 weeks for histological examination. In the histological examination, connective tissue was noted after 2 and 4 weeks around the controls, whereas, in the sputter-coated implant, new bone formation was noted after 2 and 4 weeks, without any connective tissue.
Twórcy
autor
autor
autor
  • Frontier Research and Development Center, Tokyo Denki University, Izhizaka, Hatoyama Hiki, Saitama, 350-0394, Japan, ozeki@frontier.dendai.ac.jp
Bibliografia
  • 1. Albrektsson T., Jansson T., Lekholm U.: Osseointegrated dental implants. Dental Clinics of North America 1986, 30, 151-174.
  • 2. Tweden K. S., Maze G. I., McGee T. D., Runyon C. L., Y. Niyo Y.: Evaluation of the tissue response of organic, metallic, ceramic and osteoceramic tooth roots. Materials Science Forum 1999, 293, 17-36.
  • 3. Hayashi K., Inadome T., Tsumura H., Nakashima Y, Y. Sugioka Y. :Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength. Biomaterials 1994, 15, 1187-1191.
  • 4. Ogiso M., Yamashita Y., MastumotoT.: Comparative push-out test of dense HA implants and HAcoated implants: Findings in a canine study. J. Biomed. Mater. Res. 1998, 39, 364-372.
  • 5. Ozeki K., Yuhta T., Aoki I., Nishimura I., Fukui Y.: Crystal chemistry of hydroxyapatite deposited on titanium by sputtering technique. Bio-Med. Mat. Eng. 2000, 10, 221-227.
  • 6. Ozeki K., Yuhta T., Fukui Y., Aoki H.: Phase composition of sputtered films from a hydroxyapatite target. Surface and Coatings Technology 2002, 160, 54-61.
  • 7. Ozeki K., Yuhta T., Aoki H., Nishimura I., Fukui Y.: Push-out strength of hydroxyapatite coated by sputtering technique in bone. Bio-Med. Mater. Eng. 2001, 11, 63-68.
  • 8. Ozeki K., Yuhta T., Aoki H., Nishimura I., Fukui Y.: A functionally graded titanium / hydroxyapatite film obtained by sputtering. J. Mater. Sci. Mater. Med. 2002, 13, 253-258.
  • 9. Li T., Lee J., Kobayashi T., Aoki H.: Hydroxyapatite coating by dipping method, and bone bonding strength. J. Mater. Sci. Mater. Med. 1996, 7, 355-357.
  • 10. Cao Y., Weng J., Chen J., Feng J., Yang Z., Zhang X.: Water vapour-treated hydroxyapatite coatings after plasma spraying and their characteristics. Biomaterials, 1996, 17, 419-424.
  • 11. De Groot K., Wolke J. G. C., Jansen J. A.: Calcium phosphate coatings for medical implants. Proc. Inst. Mech. Eng. 1998, Part H, 212, 137-147.
  • 12. Hasegawa S., Furuya K., Ukegawa Y., Fushimi M., Aoki H., Akao M., Higashikata M., Shimanune T., Hosonuma M.: Osteocompatibility of Hydroxyapatite-Coated Titanium by Thermal Decomposition Method, Proceedings of the First International Symposium on Apatite, Mishima, Japan 1991, 259-266.
  • 13. Tweden K. S., Maze G. I., McGee T .D., Runyon C. L., Niyo Y.: Evaluation of the tissue response of organic, metallic, ceramic and osteoceramic tooth roots. Materials Science Forum, 1999, 293, 17-36.
  • 14. Cochran D. L., Nummikoski P. V., Higginbottom F. L., Hermann J. S., Makins S. R., Buser D.: Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: radiograph results. Clin. Oral Impl. Res. 1996, 7, 240-252.
  • 15. Szmukler-Moncler S., Piattelli A., Favero G. A., Dubruille J. H.: Considerations prelimunary to the application of early and immediate loading protocols in dental implantology. Clin. Oral Impl. Res. 2000, 11, 12-25.
  • 16. Brånemark P. I.: Ossweointegration and its experimental background. J. Prosthet. Dent. 1983, 50, 399-410.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ1-0030-0010
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.