X-ray fluorescence (XRF) method is analysed as a potential tool for in-vitro analysis of light element (atomic numbers Z = 10+38) trace concentration in biological samples. A simple model of the characteristic fluorescence radiation generation, transmission and detection processes is proposed. The model permits estimation of the detection limit for various elements, as a function of measurement system parameters. The detection limit values, calculated for various elements of medical interest, are compared with their standard cincentrations in typical medical samples (blood, serum, and urine).
Wydawca
Czasopismo
Rocznik
Tom
Strony
3--20
Opis fizyczny
Bibliogr. 12 poz., rys., wykr.
Twórcy
autor
- Institute of Radioelectronics, Warsaw University of Technology, Warsaw, Poland, zaremba@ire.pw.edu.pl
Bibliografia
- [1] Nikonorow M., Urbanek-Karłowska B.: Toksykologia żywności, PZWL, Warszawa 1987.
- [2] Pawelski S., Maj S.: Normy i kliniczna interpretacja badań diagnostycznych w medycynie wewnętrznej, PZWL, Warszawa 1987.
- [3] Tweedle D.E.F.: Postępowanie w zaburzeniach metabolicznych, Warszawa, PZWL, 1989.
- [4] Curie L.A.: Limits for Qualitative Detection and Quantitative Determination. Application to Radiochemistry, Analytical Chemistry, 1968, 40, 3, 586-593.
- [5] Taylor J.R.: Wstęp do analizy błędu pomiarowego, PWN, Warszawa 1995.
- [6] "Reference Man”, International Commission of Radiological Protection, Report 23, Pergamon Press Oxford 1975.
- [7] Zaremba K.: Wybrane radiacyjne metody badania składu tkanek i płynów ustrojowych, Oficyna Wydawnicza PW, Warszawa 2002.
- [8] Jorch H.H., Campbell J.L.: On the analytic fitting of full energy peaks from Ge(Li) and Si(Li) photon detectors, Nucl. Instr. Meth., 1977, 143, 551-559.
- [9] He T., Gardner R.P., Verghese K.: An improved Si(Li) detector response function, Nucl Instr Meth. A299 (1990) 354-366.
- [10] Lepy M.C., Campbell J.L., Laborie J.M., Plagnard J„ Stemmier P. Teesdale W.J.: Experimental characterization of low-energy X-ray semiconductor detectors, Nucl Instr Meth A 422 (1999) 428-432.
- [11] McNelles L.A., Campbell J.L.: Analytic approximations to peak shapes produced by Ge(Li) and Si(Li) spectrometers, Nucl. Instr. Meth., 1975, 127, 73-81.
- [12] Knoll G.F.: Radiation detection and measurement, Wiley & Sons, New York 1989.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ1-0003-0053
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.