The work presented calculation results of a small power (1.5 kW) squirrel cage motor warm-up.Computation was realized with normal load. There is two models: one with non-damaged rotor and second one with three broken rotor bars. Calculation of coupling transient magneto-thermal field was realized with two-dimensional field-circuit motor model. There is a linear temperature characteristic of aluminum resistivity in squirrel cage, and a linear temperature characteristic of a thermal parameters in squirrel cage and core. Heating characteristic of motor with non-damaged rotor and another one with three broken rotor bars was compared. Heat distribution in rotor was investigated in both situation, in thermal transient state and after its.
Słowa kluczowe
Rocznik
Tom
Strony
84--89
Opis fizyczny
Bibliogr. 2 poz.
Bibliografia
- [1] FLUX® 8.10 User’s guide, Cedrat, MEYLAN Cedex, June 2003
- [2] FLUX® 8.10 2D Application. Induction heating tutorial, Cedrat, MEYLAN Cedex, December 2003