Rusing a halogen lamp to calibrate an optical system for UV-VIS radiation detection

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In the last few years plasmas have been used more and more in a great number of scientific and technological fields, and optical emission spectroscopy (OES) has been the most commonly used technique for their analysis. The usual optical system employed for plasma analysis is composed of a monochromator, a detector and an optical fiber, which must be calibrated to correct the different intensity response of each component in this system. For this calibration, the use of commercial halogen lamps is proposed as opposed to the commonly used ribbon lamp, involving lower economic cost.
Czasopismo
Rocznik
Strony
353--363
Opis fizyczny
Bibliogr. 10 poz.
Twórcy
autor
autor
autor
  • Grupo de Espectroscopía de Plasmas, Universidad de Córdoba, Edificio C-2, Campus de Rabanales, 14071 Córdoba, Spain, facazal@uco.es
Bibliografia
  • [1] DEVESA L., Calibración de dos canales espectroscópicos de diagnosis del plasma, Tesis de Licenciatura, Universidad de Valladolid, Valladolid 1991.
  • [2] QUINTERO M.C., RODERO A., GARCÍA M.C., SOLA A., Determination of the excitation temperature in a nonthermodynamic-equilibrium high-pressure helium microwave plasma torch, Applied Spectroscopy 51(6), 1997, pp. 778–84.
  • [3] JONKERS J., VOS H.P.C., VAN DER MULLEN J.A.M., TIMMERMANS E.A.H., On the atomic state densities of plasmas produced by the “torche a injection axiale”, Spectrochimica Acta Part B: Atomic Spectroscopy 51(5), 1996, pp. 457–65.
  • [4] RODERO A., Desarrollo y puesta a punto de métodos espectroscópicos para la diagnosis del plasma, Tesis de Licenciatura, Universidad de Córdoba, Córdoba 1995.
  • [5] GIBSON C.E., TSAI B.K., PARR A.C., Radiance Temperature Calibrations, NIST Special Publication 1997, pp. 250–43.
  • [6] DE VOS J.C., The emissivity of Tungsten Ribbon, PhD Thesis, Universidad de Eindhoven, Eindhoven 1953.
  • [7] http://www.pyrometer.com/ribbon_lamp.html.
  • [8] Laes LÁMPARAS ESPECIALES, S.A., http://www.laes.es
  • [9] YUBERO C., Calibración del sistema óptico de detección de radiación utilizado en espectroscopía de emisión, Tesis de Licenciatura, Universidad de Córdoba, Córdoba 2005.
  • [10] MOISAN M., ETEMANDI E., ROSTAING J.C., French Patent Specific, No 2 762 748 (1998). European Patent, No EP 0 874 537 A1 (1998).