The first part of the article presents dielectric response in frequency domain of aged oil-paper samples. Then, the samples were vacuum dried and the aged oil was extracted from the paper. In the end the dried paper was impregnated by new and dry oil. In each mentioned stage of investigation the dielectric response and moisture content in paper were measured. In the second part of the article the influence of mass density of moistured and impregnated pressboard samples on their dielectric response was discussed.
Rocznik
Tom
Strony
118--121
Opis fizyczny
Bibliogr. 7 poz.
Twórcy
autor
autor
- Poznan University of Technology, Institute of Electric Power Engineering
Bibliografia
- [1] Graczkowski A., Gielniak J., Przybyłek P., Szymański J., Walczak K. Neumann S.R., Porównanie wyników oceny zawilgocenia izolacji papierowo-olejowej uzyskanych przy użyciu metod fizykochemicznych i opartych na odpowiedzi dielektrycznej, VIII Ogólnopolskie Sympozjum „Inżynieria Wysokich Napięć", 8-10 maja 2006, Będlewo, Przegląd Elektrotechniczny - Konferencje, 2006, ss. 99-102.
- [2] Gielniak J., Ekanayake C, Walczak K., Graczkowski A.. Gubański S.M.. Dielectric response of new and aged transformer pressboard in dry and wet states. International Symposium on Electrical Insulating Materials ISEIM 2005, Kitakyushu, Japan, June 5-9, 2005, pp. 386-389.
- [3] J. Blennow, C. Ekanayake, K. Walczak, B. Garcia, S. M. Gubański, Field experiences with measurements of dielectric response in frequency domain for power transformer diagnostics, IEEE Transactions on Power Delivery, Vol. 21, Issue 2, April 2006, pp. 681-688.
- [4] Ekanayake C, Gubański S.M., Graczkowski A., Walczak K., Frequency Response of Oil Impregnated Pressboard and Paper Samples for Estimating Moisture in Transformer Insulation, IEEE Transactions on Power Delivery, Volume 21, Issue 3, July 2006, pp. 1309-1317.
- [5] IEC 60814, Insulating liquids - Oil-impregnated paper and pressboard - Determination of water by automatic coulometric Karl Fischer titration, second edition 1997-08.
- [6] Graczkowski A., Walczak K., Pomiar tg S w funkcji częstotliwości jako nowoczesne narzędzie diagnostyczne wysokonapięciowych układów izolacyjnych, XII Konferencja „Urządzenia i usługi elektroenergetyczne, telekomunikacyjne i informatyczne u progu XXI wieku", Poznań, 17-18 września 2003, ss. 77-80.
- [7] Linhjell D., Gafvert U., Lundgaard L.E., Dielectric response of oil-impregnated paper insulation: variation with humidity and ageing level [power transformer applications]. Conference on Electrical Insulation and Dielectric Phenomena, Annual Report, 2004, pp. 262-266,