Biomimetic growth of apatite on titania nanotube arrays fabricated by titanium anodization in NH4F/H2SO4 electrolyte

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In the present work, the titania nanotube arrays was fabricated by anodizing titanium in NH4F/H2SO4 electrolyte. The crystal structure and the apatite-forming ability of the titania nanotube arrays were investigated. The samples were examined by ESEM, XRD and FT-IR. The results indicate that the crystal structure of the titania nanotube arrays occurred transformation from amorphous to anatase and rutile as the annealed temperature rised. The surface structure of the nanotube could enhance the bioactivity of titania. The bioactivity of titania nanotube arrays lies on its the crystal structure, ranked in following series: mixture of anatase and rutile structure > anatase > amorphous.
Słowa kluczowe
Wydawca
Rocznik
Strony
487--494
Opis fizyczny
Bibliogr. 29 poz.
Twórcy
autor
autor
  • College of Chemistry and Material Science, Fujian Normal University, China Fujian, Fuzhou 350007, rfliu@vip.sina.com
Bibliografia
  • [1] LONG M., RACK H.J., Biomater., 19 (1998), 1621.
  • [2] BRUNETTE D.M., TENGVALL P., TEXTOR M., THOMSEN P., Titanium in Medicine, Springer Verlag Berlin, 2001, p.13
  • [3] LEE J., AOKI H., Biomed. Mater. Eng., 5 (1995), 49.
  • [4] GROOT K.D., GEESINK R., KLEIN C., SEREKIAN P., J. Biomed. Mater. Res., 21 (1987), 1375.
  • [5] CHEN J., TONG W., CAO Y., FENG J., ZHANG X., J. Biomed. Mater. Res., 34 (1997), 15.
  • [6] OZEKI K., YUHTA T., AOKI H., NISHIMURA I., FUKUI Y., Biomed. Mater. Eng., 10 (2000), 221.
  • [7] PHAM M.T., MAITZ M.F., MATZ W., REUTHER H., RICHTER E., STEINER G., Thin Solid Films, 379 (2000), 50.
  • [8] SHIRKHANZADEH M., J. Mater. Sci. Mater. Med., 6 (1995), 90.
  • [9] ZITOMIRSKY I., GOL-OR L., ISRAL I., J. Mater. Sci. Mater. Med., 8 (1997), 213.
  • [10] XIAO X.F., LIU R.F., ZHENG Y.Z., Mater. Lett., 59 (2005), 1660.
  • [11] ISHIZAWA H., OGINO M., J. Biomed. Mater. Res., 34 (1997), 15.
  • [12] MORRA M., CASSINELLI C., BRUZZONE G., CARPI A., DI SANTI G., GIARDINO R., FINI M., Int. J. Oral. Maxillofac Implants, 18 (2003), 40.
  • [13] TENGVALL P., ELWING H., LUNDSTROM I., J. Colloid Inter. Sci., 130 (1989), 405.
  • [14] LI P., OHTSUKI C., KOKUBO T., NANKANISHI K., SOGA N., GROOT K.D., J. Biomed. Mater. Res., 28 (1994), 7.
  • [15] PELTOLA T., PATSI M., RAHIALA H., KANGASNIEMI I., YLI-URPO A., J. Biomed. Mater. Res., 41 (1998), 504.
  • [16] KIM H.M., MIYAJI F., KOKUBO T., NAKAMURA T., J. Biomed. Mater. Res., 38 (1997), 121.
  • [17] WEN H.B., WOLKE J.G.C., WIJN J.R.D, LIU Q., CUI F.Z., GROOT K.D., Biomater., 18 (1997), 1471.
  • [18] WEN H.B., LIU Q., WIJN J.R.D., GROOT K.D., J. Mater. Sci. Mater. Med., 8 (1998), 121.
  • [19] BUNKER B.C., RIEKE P.C., TARASEVICH B.J., CAMPBELL A.A., FRYXELL G.E., GRAFF G.L., SONG L., LIU S., VIRDEN J.W., MCVAY G.L., Science, 264 (1994), 48.
  • [20] KOKUBO T., KUSHITANI H., SAKKA S., KITSUGI T., YAMAMURO T., J. Biomed. Mater. Res., 24 (1990), 721.
  • [21] YANG B.C., UCHIDA M., KIM H.M., ZHANG X.D., T KOKUBO., Biomater., 25 (2004), 1003.
  • [22] SUL Y.T., JOHANSSON C.B., JEONG Y., ALBREKTSSON T., Med. Eng. Phys., 23 (2001), 329.
  • [23] GONG D., GRIMES C.A., VARGHESE O.K., HU W., SINGH R.S., CHEN Z., DICKEY E.C., J. Mater. Res., 16 (2001), 3331.
  • [24] MOR G.K., VARGHESE O.K., PAULOSE M., MUKHERJEE N., GRIMES C.A., J. Mater. Res., 18 (2003), 2588.
  • [25] ROHRER G.S., Structure and Bonding in Crystalline Materials, Cambridge University Press, Cambridge, 2001, p. 365
  • [26] KOKUBO T., Biomater., 2 (1991), 155.
  • [27] HEALY K.E., DUCHEYNE P., J. Biomed. Mater. Res., 26 (1992), 319.
  • [28] UCHIDA M., KIM H.M., KOKUBO T., FUJIBAYASHI S., NAKAMURA T., J. Biomed. Mater. Res., 64A (2003), 164.
  • [29] TSUCHIYA H., MACAK J.M., MULLER L., KUNZE J., MULLER F., GREIL P., VIRTANEN S., SCHMUKI P., J. Biomed. Mater. Res., 77A (2006), 534.