Corrosion behaviour and bioactivity of electrophoretically deposited hydroxyapatite on titanium in physiological media (Hanks' solution)

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Hydroxyapatite (HA) coatings were developed on titanium by electrophoretic deposition at various deposition potentials from 30 to 60 V and at a constant deposition time of 5 minutes using the synthetic HA (Ca10(PO4)6(OH)2,) powder in a suspension of dimethyleformamide (DMF, HCON(CH3)2). The electrochemical corrosion behavior of the HA coatings in simulated body fluid (SBF Hanks' solution) at 37 °C and pH 7.4 was investigated by means of open-circuit potential (OCP) measurement and potentiodynamic polarization tests. The OCP test showed that the values OCP for the coated samples shifted to more noble potential than for uncoated titanium, especially after addition of dispersants. The polarization test revealed that all HA coated specimens had a corrosion resistance higher than that of the substrate, especially after addition of dispersants such as polyvinyl butyral (PVB), polyethylene glycol (PEG) and triethanolamine (TEA) to the suspension. The coating morphology after polarization, characterized by scanning electron microscopy (SEM), showed penetration of electrolyte into the HA coats. Bone bioactivity of the coatings was also studied by immersion of coated specimens in Hanks' solution for 3 and 7 days. Apatite granules growth on the surface of the HA layers was observed.
Wydawca
Rocznik
Strony
231--239
Opis fizyczny
Bibliogr. 19 poz.
Twórcy
autor
  • Department of Chemical Engineering, Tabbin Institute for Metallurgical Studies (TIMS), P.O. Box: 109 Helwan, 11421 Cairo, Egypt
Bibliografia
  • [1] BALAKRISHNANA A., LEEA B. C., KIMA T. N.,PANIGRAHIB B. B., Trends Biomater. Artif. Organs.,22(1) (2008), 66.
  • [2] KWOK C.T., WONG P.K., CHENG F.T., MAN H.C.,Appl. Surf. Sci., 255 (2009), 6736.
  • [3] GARCIA-SANZ F.J., MAYOR M.B, ARIAS J.L., POUJ., LEON B., PEREZ-AMO M., J. Mater. Sci.: Mater.Med., 8 (1997), 861.
  • [4] WANG D., CHEN C., HE T., LEI T., J. Mater. Sci.:Mater. Med., 19 (2008), 2281.
  • [5] AKSAKAL B., HANYALOGLU C., J. Mater Sci.: Mater.Med., 19 (2008), 2097.
  • [6] KUO M.C., YEN S.K., Mater. Sci. Eng. C, 20 (2002),153.
  • [7] COSTANTINI A., LUCIANI G., BRANDA F.,AMBROSIO L., MATTOGNO G., PANDOLFI L., J.Mater Sci.: Mater. Med., 13 (2002), 891.
  • [8] WANG C., MA J., CHENG W., ZHANG R., Mater. Lett.,57 (2002), 99.Corrosion behaviour and bioactivity of electrophoretically deposited hydroxyapatite on titanium inphysiological media (Hanks’ solution) 239
  • [9] ZHITOMIRSKY I., GAL-OR L., J. Mater. Sci.: Mater.Med., 8: (1997) 213.
  • [10] MENG X., KWON T., YANG Y., ONG J., KIM K., J.Biomed. Mater. Res., 78B (2006) 373.
  • [11] BOCCACCINI A.R., ZHITOMIRSKY I., Current Opinionin Solid State and Mater. Sci., 6 (2002), 251.
  • [12] ZHITOMIRSKY I., Adv. Colloid Interface Sci., 97(2002), 279.
  • [13] XIAO X.F., LIU R.F., TANG X. L., J. Mater Sci.: Mater.Med., 19 (2008), 175.
  • [14] NAVA-DINO C.G. et al., Int. J. Electrochem. Sci., 7(2012), 2389.
  • [15] RICARDO M.S., MARÍA M.L., RUI L.R., Biomater.,24 (2003), 4213.
  • [16] ABDELSATTAR A.A., SHOEIB M.A., MOHAMEDS.G., Surf. Coat. Technol., 206 (2011), 43.
  • [17] COELHO P. G., DE ASSIS S.L., COSTA I., THOMPSONV.P., J. Mater. Sci: Mater. Med., 20 (2009), 215.
  • [18] ADVINCULA M.C., PETERSEN D., RAHEMTULLA F.,ADVINCULA R., LEMONS J.E., J. Biomed. Mater. Res.B Appl. Biomater., 80 (2007), 107.
  • [19] KOKUBO T., TAKADAMA H., Biomater., 27 (2006),2907.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPW7-0023-0038
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.