Return voltage measurements Diagnostic interpretations based on the dielectric time constants

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Return voltage measurements of paper-oil insulations such as medium voltage cables have proven to be a reliable method to determine the actual state of degradation and/or the humidity of the insulation. As a first step, the interpretation of the measurements can be done based on the p-factor. This parameter is sensitive to the dielectric properties and especially the humidity of the solid part of the insulation, whereby aged or humid cables show a higher p-factor. The calculation of the dielectric time constants ?1 and ?2 of the two insulating materials oil and cellulose is unique for the return voltage method and hence exceeds the information extractable from other diagnostic methods.
Wydawca
Rocznik
Strony
1157--1169
Opis fizyczny
Bibliogr. 12 poz.
Twórcy
autor
autor
autor
  • Institute of Materials and Diagnostics in Electrical Engineering University of Siegen, Germany
Bibliografia
  • [1] NÉMETH E., Zerstörungsfreie Prüfung von Isolationen mit der Methode der Entlade- und Rückspannungen, IWK'66, Ilmenau, Germany, 1966, 87–91.
  • [2] BOGNAR A., KALOCSAI L., CSEPES G., NÉMETH E., SCHMIDT J., Diagnostic Tests of High Voltage Oil-Paper Insulating Systems (In Particular Transformer Insulation) using DC Dielectrometrics, CIGRE '90, Paris, France, 1990, 15/33–08.
  • [3] NÉMETH E., Practical experiences of diagnostic testing of power cable lines by the voltage-response method, IWK '95, Ilmenau, Germany, 1995, 699–708.
  • [4] ZAENGL W.S., IEEE EI-Mag., 19, (2003), 5.
  • [5] ZAENGL W.S., IEEE EI-Mag., 19, (2003), 9.
  • [6] PATSCH R., BERTON F., KOUZMINE O., The Influence of the Ambient Temperature on the Diagnostic Response of Paper-Oil Insulated Cables, APTADM ‘01, Wroclaw, Poland, 2001, 34–37.
  • [7] HOUHANESSIAN V.D., Measurement and Analysis of Dielectric Response in Oil-Paper Insulation Systems, PhD-Thesis, ETH Zürich, Switzerland, 1998.
  • [8] ALEKSEEV B.A., Elektrichestvo, 2 (959), 58.
  • [9] PATSCH R., KOUZMINE O., WSEAS Trans. on Circuits and Systems, 9 (2005), 1191.
  • [10] PATSCH R., KOUZMINE O., p-Factor, a Meaningful Parameter for the Evaluation of Return Voltage Measurements, CEIDP ‘02, Cancun, Mexico, 2002, 906–909.
  • [11] PATSCH R., KOUZMINE O., The Influence of Climatic Conditions on the Diagnostic Results of Return Voltage Measurements, ISEI'02, Boston, USA, 2002, 191–419.
  • [12] PATSCH R., KOUZMINE O., Return Voltage Measurements – a good Tool for the Diagnosis of Paper-Oil-Insulations, IEEE PowerTech, St. Petersburg, Russia, 2005, CD.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPW7-0012-0022
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.