A study of the gas specificity of porous silicon sensors for organic vapours

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
A porous silicon sensor was investigated as a means to determine the response specificity for organic vapours. Porous silicon layers were fabricated by electrochemical anodization of p-type crystalline silicon in an HF ethanol solution under various conditions. The porous silicon sensors were placed in a gas chamber with various organic vapours, and the changes in electrical resistance under constant voltage of each sensor were used as detection signals. The sensors recorded various changes in resistivity for various organic vapours.
Wydawca
Rocznik
Strony
603--610
Opis fizyczny
Bibliogr. 18 poz.
Twórcy
autor
autor
autor
autor
autor
autor
  • Department of Physics, Kongju National University, 314-701 Chungnam, Republic of Korea
Bibliografia
  • [1] CANHAM L.T., Appl. Phys. Lett., 57 (1990), 1046.
  • [2] CANHAM L.T., Properties of Porous Silicon, INSPEC, London, 1997.
  • [3] VIAL J.C., DERRIEN J., Porous Silicon Science and Technology, Springer-Verlag, Berlin, 1995.
  • [4] HIRSCHMAN K.D., TSYBESKOV L., DUTTAGUPTA S.P., FAUCHET P.M., Nature, 384 (1996), 338.
  • [5] SZENTPÁLI B., NOHÁCSY T., BÁRSONY I., Curr. Appl. Phys., 6 (2006), 174.
  • [6] RAVI KUMAR REDDY R., BASU I., BHATTACHARYA E., CHADHA A., Curr. Appl. Phys., 3 (2003), 155.
  • [7] BARATTO C., FAGLIA G., SBERVEGLIERI G., GABURRO Z., PANCHERI L., OTON C., PAVESI L., Sensors, 2 (2002), 121.
  • [8] OUYANG H., STRIEMER C.C., FAUCHET P.M., Appl. Phys. Lett., 88 (2006), 163108.
  • [9] PANCHERI L., OTON C.J., GABURRO Z., SONCINI G., PAVESI L., Sens. Actuators B, 89 (2003), 237.
  • [10] SALEM M.S., SAILOR M.J., HARRAZ F.A., SAKKA T., OGATA Y.H., J. Appl. Phys., 100 (2006), 083520.
  • [11] SALGADO G.G., BECERRIL T.D., SANTIESTEBAN H.J., ANDRÉS E.R., Opt. Mater., 29 (2006), 51.
  • [12] STEFANO L.D., ROTIROTI L., RENDINA I., MORETTI L., SCOGNAMIGLIO V., ROSSI M., D’AURIA S., Biosens. Bioelectron., 21 (2006), 1664.
  • [13] PÉREZ E.X., MARSAL L.F., FERRÉ-BORRULL J., TRIFONOV T., PALLARÈS J., Physica E, 38 (2007), 172.
  • [14] XU Y.Y., LI X.J., HE J.T., HU X., WANG H.Y., Sens. Actuators B, 105 (2005), 219.
  • [15] MARTÍN-PALMA R.J., TORRES-COSTA V., ARROYO-HERNÁNDEZ M., MANSO M., PÉREZ-RIGUEIRO J., MARTÍNEZ-DUART J.M., Microelectron. J., 35 (2004), 45.
  • [16] BARATTO C., COMINI E., FAGLIA G., SBERVEGLIERI G., FRANCIA G.D., FILIPPO F.D., FERRARA V.L., QUERCIA L., LANCELLOTTI L., Sens. Actuators. B, 65 (2000), 257.
  • [17] HARPER J., SAILOR M.J., Langmuir, 13 (1997), 4652.
  • [18] Standard Committee on Sensors, Standard of Electronic Industries Association of Korea EIAK GC-6220 (2000), p. 6.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPW7-0011-0117
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.