PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

New possibilities of light microscopy research resulting from digital recording of images

Identyfikatory
Warianty tytułu
Konferencja
E-MRS 2004 Fall Meeting Warsaw, Poland , 6-10 September,2004
Języki publikacji
EN
Abstrakty
EN
New research possibilities related to recent improvements in light microscopy are discussed. New research microscopes are fully automated and motorized. All functions, such as those connected with focusing or stage positioning, can be controlled with a PC. Techniques which combine images recorded at different locations on X, Y and Z axes are presented. The first technique - combining high resolution single images, made in X and Y axes on the surface of a specimen, creates overview images of specimens. This is particularly important in quantitative materialography because the technique produces a significant decrease in the edge effect. Examples of applications of PC controlled X-Y stage and stage management software in the study of a duplex steel, made from Ni-base superalloy and welding are presented. Automatic alignment of images made in applications of this technique in the study of a zinc layer on cast iron and thermal barrier coatings on a heat-resisting alloy are shown.
Wydawca
Rocznik
Strony
559--565
Opis fizyczny
Bibliogr. 10 poz.
Twórcy
autor
  • Silesian University of Technology, Department of Materials Science, Katowice, Poland
autor
  • Silesian University of Technology, Department of Materials Science, Katowice, Poland
Bibliografia
  • [1] CWAJNA J., Metody badawcze współczesnej metalografii, [in:] M. Hetmańczyk (Ed.), Postępy nauki o materiałach i inżynierii materiałowej, Wydawnictwo Politechniki Śląskiej, Gliwice, 2002, p. 15.
  • [2] WOJNAR L., Laboratoria, Aparatura, Badania, 2 (2000), 11.
  • [3] WOJNAR L., Modern approach to microstructure image analysis, [in:] L. Wojnar, K. Rożniatowski, K.J. Kurzydłowski (Eds.) Proceedings of International Conference on the Quantitative Description of Materials Microstructure Q-MAT ’97, Kraków, 1997, p. 103.
  • [4] DRENT P., Imaging & Microscopy, 1 (2001), 2.
  • [5] G.I.T. Imaging and Microscopy 4 (2003), 17 (I&M show case: cameras).
  • [6] AnalySIS User’s Guide, Soft Imaging System GmbH, Germany, 2000, 87.
  • [7] SZCZOTOK A., Wiad. Stereolog., 10 (2004), 44.
  • [8] Axiovert 200 MAT (company brochure www.zeiss.de/mat).
  • [9] Axioskop 2 MAT (company brochure www.zeiss.de/mat).
  • [10] AxioVision (company brochure www.zeiss.de/axiovision).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPW7-0002-0055
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.