Luminous flux calibration facility with an integrating sphere has been installed at the National Metrology Institute of Turkey (UME) in order to realize lumen. A LabView-based computer-controlled electrical system has been developed to operate light sources and to control electrical parameters. Owing to the corrections of the sphere system, inner coating reflectance, spatial non-uniformity, self-absorption factor and interior temperature variations have been characterized. The overall uncertainty in luminous flux measurement has been determined with an uncertainty of 1.14% (k = 2) in the range between 5–5000 lm
Czasopismo
Rocznik
Strony
265--274
Opis fizyczny
Bibliogr. 14 poz., rys., tab.
Twórcy
autor
  • TÜBITAK-Ulusal Metroloji Enstitüsü (UME), P.O.54, 41470, Kocaeli – TURKEY
autor
  • TÜBITAK-Ulusal Metroloji Enstitüsü (UME), P.O.54, 41470, Kocaeli – TURKEY
Bibliografia
  • [1] The measurement of luminous flux, CIE Publication, Vol. 84, 1989.
  • [2] The measurement of absolute luminous intensity distributions, CIE Publication, Vol. 70, 1987.
  • [3] CASIMER DECUSATIS, Handbook of Applied Photometry, Woodbury, N.Y., AIP Press 1998.
  • [4] RASTELLO M.L., MIRALDI E., PISONI P., J. Appl. Opt. 35 (1996), 4385.
  • [5] JONES O.C., BERRY R.G., Metrologia 6 (1970), 81.
  • [6] FÖRSTE D., Ein Goniophotometer zur genauen Bestimmung des Lichtstroms, Licht Forschung 1 (1979), 30.
  • [7] BASTIE J., ANDASSE B., FOUCART R., Luminous flux measurements with a goniophotometer: study of time effects on data collection, [In] Proceeding of the 22nd Session of CIE, Vol. 1, 1991, pp. 45–47.
  • [8] FÖRSTE D., SAUTER G., MARTIN H., Elimination des Fremdlichts bei der Lichtstrombestimmung mit dem Goniophotometer, Licht Forschung, 2, 1980, pp. 27-35.
  • [9] OHNO Y., J. Appl. Opt. 33 (1994), 2637.
  • [10] VENABLE W.H., HSIA J.J., WEIDNER V.R., J. Res. NBS 82 (1977), 29.
  • [11] SAUTER G., LINDNER D., LINDEMANN M., CCPR Key Comparisons K3a of Luminous Intensity and K4 of Luminous Flux with Lamps as Transfer Standards, PTB-Opt-62, 1999, Braunschweig Dezember.
  • [12] Guide to the Expression of Uncertainties in Measurements, International Organization for Standardization, Geneva, Switzerland 1995.
  • [13] International Vocabulary of Basic and General Terms in Metrology, International Organization for Standardization, Geneva, Switzerland, 1995.
  • [14] SAUTER G., GOODMAN T., Determination of Measurement Uncertainties in Photometry, CIE-TC2-43, 1999.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPW1-0015-0023
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.