PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Image analysis and statistical evaluation of two-dimensional human eye retina images of healthy and glaucomatous eyes

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In this paper, a new automatic glaucoma diagnostic method for determining the probability of glaucoma occurring in a eye under study is described. This method is based on computer analysis of two-dimensional images of the blind spot of the human eye retina and on successive statistical evaluation of the data obtained. First, the characteristic symptoms of glaucoma are shortly described. Next, a suitable numerical parameter of the retina blind spot is defined. The method of computer image analysis for automatic determination of the parameter in question is described and it is applied to a set of normal healthy eye images and to a set of glaucomatous eye images. The probability of glaucoma occurring for each value of the parameter introduced is suitably defined and computed by virtue of statistical evaluation of the results obtained
Czasopismo
Rocznik
Strony
521--531
Opis fizyczny
Bibliogr. 18 poz., rys., tab.
Twórcy
  • Department of Experimental Physics and Joint Laboratory of Optics of Palacký University and Institute of Physics of Academy of Sciences, 17. listopadu 50a, 772 07 Olomouc, Czech Republic
autor
  • Department of Experimental Physics and Joint Laboratory of Optics of Palacký University and Institute of Physics of Academy of Sciences, 17. listopadu 50a, 772 07 Olomouc, Czech Republic
Bibliografia
  • [1] Shields B., Textbook of Glaucoma, Williams & Wilkins, Baltimore 1992.
  • [2] Hanuš K., Boguszaková J., Diblík P., Dotřelova D., Filipec M., Hycl J. Karel I., Kocour I., Kraus H., Křepelková J., Kuchynka P., Otradovec J., PalečkovA J., Peregrin J., Řehuřek J., Švéřák J., Šedivý A., Compendium of Eye Medicine, Grada, Praha 1997 (in Czech).
  • [3] Nesterov A. P., Primary Glaucoma, Avicenum, Praha 1991 (in Czech).
  • [4] Řehák S., Knobloch R., Riebel O., Vrabec F., Medicine of the Eye, Avicenum, Praha 1980 (in Czech).
  • [5] Nagin P., Schwartz B., Ophthalmology 92 (1985), 252.
  • [6] Nover A., The Ocular Fundus, Methods of Examination and Typical Findings, Schattauer, Stuttgart 1987.
  • [7] Sauter H., Straub W., Rossmann H., Atlas of the Ocular Fundus, Photographs of Typical Changes in Ocular and Systemic Disease, Urban & Schwarzenberg, Miinchen 1997.
  • [8] Cornsweet T. N., Hersh S., Humphries J.C., Beesmer R.J., Cornsweet D.W, Quantification of the shape and color of the optic nerve head, [In] Advances in Diagnostic Visual Optics, G.M. Breinin, l.M. Siegel, Springer-Verlag, New York 1983, pp. 141-149.
  • [9] Cornsweet T.N., Hersh S., Ocular-Fundus Analyze, U.S. Patent No. 4715703, U.S. Government, Washington 1987.
  • [10] Pluháček F., Pospišil J., Fine Mechanics and Optics 46 (2001), 326 (in Czech).
  • [11] Shioiri T., Ophthalmologic Image Processor, U.S. Patent No. 6104828, U.S. Government, Washington 2000.
  • [12] Mikelberg F. S., Wijsman K., Schulzer M., J. Glaucoma 2 (1993), 101.
  • [13] Zinser G., Harbarth U., Schröder H., Formation and analysis of three-dimensional data with the laser tomographic scanner (LST), [In] Scanning Laser Ophthalmoscopy and Tomography, J.E. Nasemann, R.O.W. Burk, Quintessenz Velrlag, München 1990 pp. 243-252.
  • [14] Bartz-Schmidt K. U., Sengersdorf A., Esser P., Walter P., Hilgers R.D., Krieglstein G.K., Greafe’s Archive for Clinical and Experimental Ophthalmology 234 (1996), 227.
  • [15] Varma R., Spaeth G.L., Ophthalmic Surgery 19 (1988), 183.
  • [16] Kubáček L., Kubáčková L., Statistics and Metrology, Palacky University Press, Olomouc 2000 (in Czech).
  • [17] Škrášek J., Tichý Z., Principles of Applied Mathematics III, SNTL, Praha 1990 (in Czech).
  • [18] Klein B.E.K., Klein R., Sponsel W.E., Franke T., Cantor L.B., Martone J., Ophthalmology 99 (1992), 1499.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPW1-0014-0037
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.