PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The Efficient Technique for Harmonic Sources Detection AT Power Grid

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Skuteczna metoda detekcji źródeł wyższych harmonicznych w sieci energetycznej
Języki publikacji
EN
Abstrakty
EN
In this paper, we propose a new and efficient method for detection and quantifying the level of distortion caused by non-linear loads on the power grid. It is based on measurement of distortion power. Simulated and measured results confirm its effectiveness when implemented within electronic power-meters. The proposed solution can easily be added as an option to existing solid-state power-meters. It can be implemented as a software update or in the form of hardware upgrade within a dedicated DSP.
PL
W artykule zaprezentowano metodę detekcji oraz oceny zakłóceń energii w sieci energetycznej wywołanych przez odbiorniki nieliniowe. Wyniki symulacyjne potwierdzają skuteczność metody.
Rocznik
Strony
196--199
Opis fizyczny
Bibliogr. 17 poz., tab., rys.
Twórcy
autor
Bibliografia
  • [1] Singh, G.K., Power system harmonics research a survey, European Transactions on Electrical Power, Vol.19, 2007, pp. 151–172.
  • [2] Wakileh. J. G., Power Systems Harmonics, Springer, 2001
  • [3] Xu W., Liu X., Liu Y.: An investigation on the validity of powerdirection method for harmonic source determination, IEEE Trans. Power Delivery, vol. 18, no.1, January 2003. pp. 214- 218
  • [4] Lee S., Park J. W., New power quality index in a distribution power system by using RMP model, IEEE Tran. On Industrial Applications, vol. 46, no.3, May/June 2010, pp. 1204 – 1211
  • [5] Chun L., Xu W., and Tayjasanant T., A critical impedance based method for identifying harmonic sources, IEEE Trans. Power Del., vol. 19, no. 2, Apr. 2004 pp. 671–678.
  • [6] Barbaro P.V., Cataliotti A., Cosentino V., Nuccio S. A new technique to detect harmonic sources in polluted power systems, Proc. of the XVIII IMEKO World Congress, 2006, Rio de Janeiro, Brazil.
  • [7] Cataliotti A., Cosentino V., A single-point approach based on IEEE 1459-2000 for the identification of detection of prevailing harmonic sources in distorted three phase power systems, Proc. of the Metrology and Measurement Systems, 2009.
  • [8] Emanuel A. E., Summary of IEEE standard 1459: definitions for the measurement of electric power quantities under sinusoidal, nonsinusoidal, balanced, or unbalanced conditions, IEEE Tran. On Industrial Applications, Vol. 40, No. 3, May 2004 pp. 869–876.
  • [9] Webster J. G., The measurement, instrumentation, and sensors handbook, IEEE Press, 1999
  • [10] Emanuel A. E., Power Definitions and the physical mechanism of power, Wiley and IEEE Press, 2010.
  • [11] IEEE Std 1459-2010, IEEE Standard Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced, Or Unbalanced Conditions.
  • [12] Z. Wei, Compact Fluorescent Lamps phase dependency modelling and harmonic assessment of their widespread use in distribution systems, Electronic Theses and Dissertations, Uni. of Canterbury, Christchurch, New Zealand, 2009
  • [13] EWG - multi metering solutions, www.ewg.rs
  • [14] IEC 62052-11 Electricity metering equipment (AC) – General requirements, tests and test conditions - Part 11: Metering equipment.
  • [15] EETimes, Research project illuminates OLEDs' industrial future
  • [16] Stevanović D., Petković P., Jovanović B., Modelling and Simulation of Power Consumption at Nonlinear Loads, Int. J. of Research and Reviews in Computer Science (IJRRCS)- Special Issue, Science Academy Publisher United Kingdom, April, 2011, pp. 27-32.
  • [17] http://leda.elfak.ni.ac.rs/projects/IMPEG/impeg.htm
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS4-0004-0084
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.