This paper presents the results and method of optimization the elliptical applicator used in the magnetotherapy of fractures. Eight parameters describing the structure and position of the applicator have been adopted. The authors discuss three variants of the fitness function and the reasons for choosing one of them. Due to the complicated boundaries of feasible solutions, the fitness function is increased by the value returned by the penalty function for all the individuals. The article also describes the influence of selected parameters on the behavior of the fitness function in the neighborhood of the point optimal is presented.
PL
W artykule przedstawiono metodę i wyniki optymalizacji aplikatora eliptycznego, wykorzystywanego w magnetoterapii złamań. Przyjęto osiem parametrów opisujących budowę i położenie aplikatora, omówiono trzy warianty funkcji celu wraz z uzasadnieniem wyboru jednej z nich. Ze względu na skomplikowane granice zbioru rozwiązań dopuszczalnych, do oceny osobników dołączono odpowiednią funkcję kary. Przedstawiono wpływ wybranych parametrów na zachowanie funkcji celu w otoczeniu punktu optymalnego. (Wpływ parametrów i położenia aplikatora na rozkład pola magnetycznego podczas magnetoterapii).
Rocznik
Strony
124--127
Opis fizyczny
Bibliogr. 16 poz., rys.
Twórcy
autor
autor
  • AGH Akademia Górniczo-Hutnicza w Krakowie, Katedra Elektrotechniki i Elektroenergetyki, aciesla@agh.edu.pl
Bibliografia
  • [1] Krawczyk A., Łada-Tondyra E.: Pierwsze próby stymulacji magnetycznej – historia odkryć dwóch uczonych, Przegląd Elektrotechniczny, 86 (2010), n.12, 202-205
  • [2] Cieśla A., Kraszewski W., Tadeusiewicz R.: Visualization of magnetic field generated by portable coil designed for magnetotherapy, Przegląd Elektrotechniczny, 88 (2012), n.10a, 127-131
  • [3] Ceynowa M., Sobierajska A., Biegański S., Bieniecki M., Lorczyński A. : Odlegle efekty leczenia złamań dalszego odcinka kości ramiennej u dzieci, Annales Academiae Medicae Gedanensis, 36 (2006), 21-32
  • [4] Starzyński J., Szmurło R., Kijanowski J., Dawidowicz B., Sawicki B., Wincenciak S.: Distributed Evolutionary Algorithm for Optimization in Electromagnetics, IEEE Transactions on Magnetics, 4 (2006), 42, 1243-1246
  • [5] Hsiung Hsu K., Durand D.M.: A 3-D Differential Coil Design for Localized Magnetic Stimulation, IEEE Transactions on Biomedical Engineering, 10 (2001), 48, 1162-1168
  • [6] Cieśla A. , Syrek P.: Parametric curves in the specification of windings of applicators used in magnetotherapy, Przegląd Elektrotechniczny, 88 (2012), n.9a, 213-216
  • [7] Krawczyk A., Miaskowski A., Ishihara Y. , Łada-Tondyra E.: Healing of orthopaedic diseases by means of electromagnetic field,, Przegląd Elektrotechniczny, 86 (2010), n.12, 72-74
  • [8] Cieśla A., Kraszewski W., Skowron M., Syrek P.: Determination of safety zones in the context of the magnetic field impact on the surrounding during magnetic therapy, Przegląd Elektrotechniczny, 87 (2011), n.7, 79-82
  • [9] Krawczyk A., Pławiak-Mowna A., Miaskowski A.: Badania kardioimplantów w polu elektromagnetycznym w środowisku pracy, Przegląd Elektrotechniczny, 81 (2005), n.12, 28-30
  • [10] Trigano A., Blandeau O., Souques M., Gernez J.P. , Magne I .: Clinical study of interference with cardiac pacemakers by a magnetic field at power frequencies, J Am Coll Cardiol., 2005, 15; 45(6), 896-900
  • [11] Karpowicz J., Gryz K., Zradzińsk i P.: Pola magnetyczne przy urządzeniach do magnetoterapii – ocena ryzyka zawodowego, Bezpieczeństwo Pracy, 9(2008), 21-25
  • [12] American Conference of Governmental Industrial Hygienists (ACGIH) – Threshold Limit Values for Chemical Substances and Physical Agents. Biological Exposure Indices. 2007
  • [13] Dawson T.W., Caputa K., Stuchly M.A.,Shepard R.B., Kavet R., Sastre A. : Pacemaker Interference by Magnetic Fields at Power Line Frequencies, IEEE Transactions on Biomedical Engineering, 49(3), 2002, 254-262
  • [14] Augello A., Della Chiara G., Mariani Primiani V., Mogl ie F.: Immunity Tests of Implantable Cardiac Pacemaker Against CW and Pulsed ELF Fields: Experimental and Numerical Results, IEEE Transactions on Electromagnetic Compatibility, 3 (2006), 48, 502-515
  • [15] Caminiti , I. M.V.; Formisano, A.; Lupoli, M. C.; Mar tone, R.; A new approach to design flexible magnetic active shielding, IEEE Transactions on Magnetics, vol.PP, no.99, 1-5
  • [16] Arabas J. : Wykłady z algorytmów ewolucyjnych, Wydawnictwa Naukowo-Techniczne, Warszawa, 2001
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS3-0026-0079
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.