Sensorless Field Oriented Control Strategy for Single Phase Line-Start PMSM Drive

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Bezczujnikowe sterowanie silnikiem jednofazowym z napędem PMSM
Języki publikacji
EN
Abstrakty
EN
In this paper, sensorless field oriented control strategy has been presented for single phase LSPMSM drive. Single phase type of LSPMSM is the same as single phase induction motor which has embedded permanent magnet in caged rotor. This modified motor provides higher efficiency than induction motor and has a better power factor. Also, two-leg topology of inverter used in this scheme provides regenerative mode operation and power factor control. Field oriented control (FOC) strategy is a high performance method which has been used in this paper. For elimination of required sensor in FOC method, A Phase Locked Loop (PLL) observer has been used to extract rotor speed from stator voltages and currents.
PL
Przedstawiono strategię bezczujnikowego sterowania napędem jednofazowym PSPMSM. Do tego celu wykorzystano zmodyfikowany silnik indukcyjny z wbudowanym wirnikiem zawierającym magnes stały. Zamiast czujników stosuje się obserwator typu PLL. (Bezczujnikowe sterowanie silnikiem jednofazowym z napędem PMSM)
Rocznik
Strony
229--232
Opis fizyczny
Bibliogr. 9 poz., rys., tab.
Twórcy
autor
autor
Bibliografia
  • [1] A. H. Isfahani, S. Vaez-Zadeh, "Review: Line start permanent magnet synchronous motors: Challenges and opportunities", pp. 1755-1763, Elsevier, Energy journal, no. 34, Apr, 2009.
  • [2] B.N. Chaudhari and B.G. Fernandes, “Performance of line start permanent magnet synchronous motor with single-phase supply system", IEE Proc.-Electr. Power Appl., Vol. 151, No. 1, Jan. 2004.
  • [3] T.J.E Miller, M. Popescu, C. Cossar, M.I. McGilp, G. Strappazzon, N. Trivillin, R. Santarossa, "Line-Start Permanent Magnet Motor Single-phase Steady-State Performance Analysis", IEEE conf, 2003.
  • [4] J. Zhou, K.J. Tseng, "Performance Analysis of Single-Phase Line-Start Permanent-Magnet Synchronous Motor", IEEE Trans. Energy Conversion, vol. 17, no. 4, Dec. 2002.
  • [5] M. Popescu, T. J. E. Miller, M. McGilp, G. Strappazzon, N. Trivillin, and R. Santarossa, "Line-Start Permanent-Magnet Motor: Single-Phase Starting Performance Analysis", IEEE Trans. Ind. Appl, vol. 39, no. 4, pp. 1021-1031, Jul/Aug 2003.
  • [6] M. Jemli, H.i B. Azza, M. Boussak, and M. Gossa, "Sensorless Indirect Stator Field Orientation Speed Control for Single-Phase Induction Motor Drive", IEEE Trans. Ind. Electron, vol. 24, no. 6, Jun. 2009.
  • [7] M. B. D.Corrêa, C. B. Jacobina, A. M. N. Lima, E. R. C. da Silva, "Rotor-Flux-Oriented Control of a Single-Phase Induction Motor Drive", IEEE Trans. Ind. Electron, vol. 47, no. 4, pp.832-841, Aug. 2000.
  • [8] T. J. E. Miller, "Single-Phase Permanent-Magnet Motor Analysis", IEEE Trans. Ind. Appl, vol. IA-2 1, no. 4, pp. 651-658, May/Jun 1985.
  • [9] "Vector Control Strategies for Single-Phase Induction Motor Drive Systems", IEEE Trans. Ind. Electron, vol. 51, no. 5, pp.1073-1080, Oct. 2004.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS3-0025-0065
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.