PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Monitorowanie stanu agregatów krytycznych napędzanych silnikami elektrycznymi dużych mocy

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
EN
Condition monitoring of critical aggregates driven by high power motors
Języki publikacji
PL
Abstrakty
EN
A goal of the paper is a presentation of new approach for condition management of aggregates driven by medium voltage electrical motors. The approach exclusively allows evaluation of stator technical condition. In the case of critical aggregates driven by motors with slide bearings over 60% of motor malfunctions is due to stator failures. Therefore, it is important to have a reliable tool that recognizes stator aging. The approach is an alternative for the partial discharge one, and uses high sensitivity current transformers. Postprocessing of signals connected to this malfunction-dedicated monitor allows On-Line information about stator aging progress.
Rocznik
Tom
Strony
183--188
Opis fizyczny
Bibliogr. 10 poz.
Twórcy
autor
Bibliografia
  • [1]. API STD 670, Machinery Protection Systems, 4th edition, DEC 2000.
  • [2]. Nowicki R.: Zróżnicowanie systemów On-Line nadzoru stanu technicznego agregatów z napędami elektrycznymi. Zeszyty Problemowe - Maszyny Elektryczne, 2011, Nr 89, s. 65-73.
  • [3]. Geiman J.: On-Line Motor Monitoring, Baker Instrument Co.
  • [4]. Stone G.C. i inni, Electrical Insulation for Rotating Machines: Design, Evaluation, Aging, Testing, and Repair. IEEE PRESS series on Power Engineering, USA, JAN 2004.
  • [5]. Thomson A., Advancements in Motor Condition Monitoring, publikacja wewnętrzna GE, Minden, APR 2010.
  • [6]. Penrose H. W., Test methods for determining the impact of motor condition on motor efficiency and reliability, Ph.D. dissertation, ALLTEST Pro, LLC, Old Saybrook, CT.
  • [7]. Grubic, S., A New Concept for Online Surge Testing for the Detection of Winding Insulation Deterioration in Low-Voltage Induction Machines, SEP 2011, IEEE Transactions on Industry Appl.
  • [8]. Ali S. Al-Shahrani, Influence of Adjustable Speed Drive on Induction Motor Fault Detection Using Stator Current Monitoring, AUG 2005, Oregon.
  • [9]. Whitefield C.D., New Online Motor Stator Insulation Monitor (MSIM) for 3500 SYSTEM, ORBIT, Vol. 32, No. 1, p.8-11, 2012.
  • [10]. Subocz J., Ocena jakości wykonania izolacji maszyn WN na podstawie pomiarów niskoczęstotliwościowych, Zeszyty Problemowe – Maszyny Elektryczne, 2007, Nr 76, s. 101-107.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS2-0065-0032
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.