Impact of supply voltage unbalance on stator winding fault detection in induction motor
Języki publikacji
Abstrakty
In this paper impact of supply anomalies on the machine diagnosis is presented. Diagnosis in sense at stator winding fault in case of turn to turn fault. The results of experimental in the case of physical modelling of stator short-circuits at different voltage asymmetry degree are presented. Damage of a stator winding was modelled by changing number of shorted turns in each phase. Supply voltage unbalance was modelled by increasing resistance in each motor phase. Analysis of symmetrical components of stator voltage and current was applied to investigation the asymmetry impact on shorted turns detection. Tests have been performed for the direct net supply at different load torques.
Czasopismo
Rocznik
Tom
Strony
61--66
Opis fizyczny
Bibliogr. 7 poz., rys.
Twórcy
autor
autor
- Politechnika Wrocławska, Instytut Maszyn, Napędów i Pomiarów Elektrycznych, ul. Smoluchowskiego 19, 50-372 Wrocław, czeslaw.t.kowalski@pwr.wroc.pl
Bibliografia
- [1] GRUBIC S., ALLER J.M., BIN LU, HABETLER T.G., A Survey on Testing and Monitoring Methods for Stator Insulation Systems of Low-Voltage Induction Machines Focusing on Turn Insulation Problems, IEEE Transactions On Industrial Electronics, vol. 55, no. 12, 2008, pp. 4127-4136.
- [2] HENAO H., ASSAF T., CAPOLINO G.A., The discrete Fourier transform for computation of symmetrical components harmonics. Power Tech Conf. Proceedings, 2003 IEEE Bologna, Vol. 4, 2003.
- [3] IRAVANI M.R., KARIMI-GHARTEMANI M., Online estimation of steady state and instantaneous symmetrical components. IEE Proceedings Generation, Transmission and Distribution, Vol. 150, No. 5, 2003, pp. 616-622.
- [4] KOWALSKI Cz.T., WOLKIEWICZ M, Stator faults diagnosis of the converter-fed induction motor using symmetrical components and neural networks. 13th European Conference on Power Electronics and Applications, EPE 2009, Spain.
- [5] WOLKIEWICZ M., Wpływ niesymetrii konstrukcyjnej uzwojenia stojana oraz asymetrii napięcia zasilania na wykrywanie zwarć zwojowych silnika indukcyjnego, Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej, Studia i Materiały. 2010, nr 30, s.321-331.
- [6] WOLKIEWICZ M, KOWALSKI Cz.T., Nieinwazyjne metody wczesnego wykrywania zwarć zwojowych w silniku indukcyjnym zasilanym z przemiennika częstotliwości, cz. I. Maszyny Elektryczne. Zeszyty Problemowe. 2010, nr 87, s. 145-150.
- [7] PN-EN 50160, Parametry napięcia zasilającego w publicznych sieciach rozdzielczych., Polski Komitet Normalizacyjny, Warszawa, 2008.