PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Silnik indukcyjny zasilany napięciem zawierającym składowe interharmoniczne

Treść / Zawartość
Identyfikatory
Warianty tytułu
EN
Induction motor supplied with voltage containing interharmonic components
Języki publikacji
PL
Abstrakty
EN
This paper deals with influence of voltage interharmonics on currents in an induction cage machine. The results of investigations are presented for 5,5 kW four-pole induction cage machine under supply with voltage containing positive-sequence and negative sequence interharmonic injections of various frequencies. The phenomena that have been known from computer simulations only, are confirmed by experimental method. It is proved in this paper that positive-sequence voltage interharmonics have result in current subharmonics flowing in machine windings. The significant dependency between the frequency of voltage interharmonics and the amplitude of current subharmonics, which has been known so far from theoretical calculations, is confirmed experimentally as well.
Rocznik
Tom
Strony
175--179
Opis fizyczny
Bibliogr. 16 poz., rys.
Twórcy
autor
Bibliografia
  • [1] de Abreu J. P. G., Emanuel A. E.: Induction motor thermal aging caused by voltage distortion and imbalance: loss of useful life and its estimated costs IEEE Transactions on Industry Applications, vol. 38, January/February 2002, pp. 12-20.
  • [2] Fuchs E. F., Roesler D. J., Kvacs K. P.: Aging of electrical appliances due to harmonics of the power system voltage: IEEE Trans. on Power Delivery, vol PWRD-1, no. 3, Jul. 1986, pp.: 301-307
  • [3] Fuchs E. F., Roesler D. J., Masoum M. A. S.: Are harmonics recommendations according to IEEE and IEC too restrictive? IEEE Trans. on Power Delivery 2004; 19(4):1775-1786.
  • [4] Gnaciński P.: Wybrane zagadnienia wpływu jakości energii elektrycznej na obciążenia cieplne silników indukcyjnych klatkowych małej mocy. Wydawnictwo Akademii Morskiej w Gdyni, Gdynia 2009
  • [5] Gnaciński P.: Effect of unbalanced voltage on windings temperature, operational life and load carrying capacity of induction machine. Energy Conversion and Management, vol. 49, no 4, pp. 761-770, Apr. 2008, doi. 10.1016/j.enconman.2007.07.33
  • [6] Gnaciński P.: Prediction of windings temperature rise in induction motors supplied with distorted voltage. Energy Conversion and Management, , vol. 49, no 4, pp. 707-717, Apr. 2008, doi. 10.1016/ j.enconman.2007.07.23
  • [7] Gnacinski P.: Windings temperature and loss of life of an induction machine under voltage unbalance combined with over or undervoltages. IEEE Trans. on Energy Conversion, vol. 23, no 2, June 2008, pp. 363-371, DOI 10.1109/TEC.2008.918596
  • [8] Gnaciński P.: Effect of power quality on windings temperature of marine induction motors. Part I. Machine model, Energy Conversion and Management (ELSEVIER, vol. 50, no. 10, October 2009, pp. 2463-2476.
  • [9] Gnaciński P., Mindykowski J., Tarasiuk T.: Effect of power quality on windings temperature of marine induction motors. Part II. Results of investigations and recommendations for related regulations, Energy Conversion and Management (ELSEVIER), vol. 50, no. 10, October, pp. 2477-2485.
  • [10] Gnaciński P., Pepliński M., Szweda M., The effect of subharmonics on induction machine heating, Proc. of 13th International Power Electronics and Motion Control Conference EPE-PEMC 2008, Poznań, 1-3 września 2008, pp. 826-829.
  • [11] Gnaciński P., Pepliński M., Szweda M.: Wpływ interharmonicznych na obciążenie cieplne silnika indukcyjnego, Zeszyty Naukowe Akademii Marynarki Wojennej, nr 178A, s. 99-104, Gdynia 2009
  • [12] Gnaciński P., Pepliński M., Szweda M.: Wpływ podharmonicznych na obciążenie cieplne silnika indukcyjnego, Zeszyty Problemowe – Maszyny Elektryczne, nr 84/2009, Katowice 2009, s. 97-101.
  • [13] Ho S. L., Fu W. N.: Analysis of indirect temperature-rise tests of induction machines using time stepping finite element method, IEEE Transactions on Energy Conversion, vol. 16, no. 1, March 2001, pp. 55-60.
  • [14] Pillay P., Manyage M.: Loss of life in induction machines operating with unbalanced supplies. IEEE Transaction on Energy Conversion vol. 42, pp. 813-822, Dec. 2006, doi: 10.1109/TEC.2005.853724
  • [15] Tennakoon S.; Perera S.; Robinson D.: Flicker attenuation—Part I: Response of three-phase induction motors to regular voltage fluctuations, IEEE Transactions on Power Delivery, vol. 23, no. 2, April 2008, pp.: 1207 – 1214
  • [16] PN-EN 61000-2-4:2003, Kompatybilność elektromagnetyczna (EMC) – Część 2-4, Środowisko – Poziomy kompatybilności dotyczące zaburzeń przewodzonych małej częstotliwości w sieciach zakładów przemysłowych
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS2-0057-0043
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.