Identyfikatory
Warianty tytułu
Non-invasive early detection methods of shorted turns in converter-fed induction motor, part I
Języki publikacji
Abstrakty
This paper deals with the problem of the early stator faults (the short-circuits) detection and localization of the induction motors supplied from the frequency converter. A stator fault detection method based on monitoring of RMS stator current value, the phase shift between the line currents, the spectral analysis of the line current and negative current symmetrical component analysis are presented. Tests were realized for different load torque and supply frequencies, what enabled the evaluating of the usefulness of the proposed analysis in the diagnostics of the stator faults in the converter-fed induction motor drives.
Czasopismo
Rocznik
Tom
Strony
145--150
Opis fizyczny
Bibliogr. 12 poz., rys.
Twórcy
autor
autor
- Politechnika Wrocławska, Instytut Maszyn, Napędów i Pomiarów Elektrycznych, ul. Smoluchowskiego 19, 50-372 Wrocław, marcin.wolkiewicz@pwr.wroc.pl
Bibliografia
- [1] Siddique A., Yadava G.S., Singh B.: A Review of Stator Fault Monitoring Techniques of Induction Motors. IEEE Transactions On Energy Conversion, Vol.20, No.1, March 2005, pp. 106-114.
- [2] Grubic, S., Aller J.M., Lu B., Habetler T.G.: A Survey on Testing and Monitoring Methods for Stator Insulation Systems of Low-Voltage Induction Machines Focusing on Turn Insulation Problems. IEEE Transactions On Industrial Electronics, Vol.55, No.12, December 2008, pp. 4127-4136.
- [3] Kowalski Cz.T.: Monitorowanie i diagnostyka uszkodzeń silników indukcyjnych z wykorzystaniem sieci neuronowych. Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych P.Wr., seria Monografie nr 18, zeszyt 57, 2005r.
- [4] Zhang P., Du Y., Habetler T.G., Lu B.: A Survey of Condition Monitoring and Protection Methods for Medium Voltage Induction Motors. Energy Conversion Congress and Exposition, 2009. ECCE 2009. IEEE, pp.3165-3174
- [5] Behbahanifard H., Karshenas H., Sadough A.: Non-invasive On-line Detection of Winding Faults in Induction Motors –A Review. 2008 International Conference on Condition Monitoring and Diagnosis, China, 2008, pp. 188-191
- [6] Bouzid M.B.K., Champenois G., Bellaaj N.M., Signac L., Jelassi K..: An Effective Neural Approach for the Automatic Location of Stator Interturn Faults in Induction Motor. IEEE Transactions On Industrial Electronics, Vol.55, No.12, December 2008, pp. 4277–4289
- [7] Kowalski Cz.T., Wierzbicki R., Wolkiewicz M.: Analiza wpływu uszkodzenia uzwojenia stojana silnika indukcyjnego na kąt przesunięcia fazowego pomiędzy prądem i napięciem. Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały. 2009, nr 29, s. 252-265
- [8] Thomson W.T.: On-line MCSA to diagnose shorted turns in low voltage stator windings of 3-phase induction motors prior to failure. Electric Machines and Drives Conference, 2001. IEMDC 2001. IEEE International, pp. 891-898
- [9] Joksimovic G.M., Penman J.: The Detection of Inter-Turn Short Circuits in the Stator Windings of Operating Motors. IEEE Transactions On Industrial Electronics, Vol.47, No.5, October 2000, pp. 1078–1084
- [10] Kowalski Cz.T., Wolkiewicz M.: Stator faults diagnosis of the converter-fed induction motor using symmetrical components and neural network. 13th European Conference on Power Electronics and Applications,. EPE '09, 2009
- [11] Henao H., Assaf T., Capolino G.A.: The discrete Fourier transform for computation of symmetrical components harmonics. Power Tech Conference Proceedings, Vol. 4, 2003
- [12] Arkan M., Perovic D.K., Unsworth P.: Online stator fault diagnosis in induction motors, Proc. Inst. Elect. Eng.,Elect. Power Appl., vol. 148, no. 6, 2001, pp. 537–547
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS2-0056-0085