Identyfikatory
Warianty tytułu
Use of the correlation function in on-line measurements of partial discharges of electric motors
Języki publikacji
Abstrakty
Partial discharges accompanying operation of electric motors have a very complex nature. On-line measurements require specialist partial discharge detectors and partial discharge analysing devices. The analysis of signals for diagnostic purposes should be conducted taking into account phase-resolved distributions and mutual correlations between partial discharges and load, temperature and humidity. Together with progressing use of motors, there is a change in the intensity of partial discharges with typical phase-resolved distributions and typical types of correlations. The paper presents results of measurements of partial discharges in industrial motors, including the correlation function, in particular the Pearson's linear correlation coefficient for parameters of partial discharges as well as load, temperature and humidity. Further research in this respect is necessary.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
99--104
Opis fizyczny
Bibliogr. 8 poz., rys., tab.
Twórcy
autor
- Politechnika Opolska. Wydział Elektrotechniki, Automatyki i Informatyki. Instytut Układów Elektromechanicznych i Elektroniki Przemysłowej. 45-951 Opole ul. Luboszycka 7, s.szymaniec@po.opole.pl
Bibliografia
- [1]. ADWEL: PD monitoring. Nota Aplikac. 2003.
- [2]. BENDAT J., PIERSOL A.: Metody analizy i pomiaru sygnałów losowych, Państwowe Wydawnictwo Naukowe, Warszawa 1976.
- [3]. Bertenshaw D., Sasic M.: On-line Partial Discharge Monitoring on MV motors-Casestudies on Improved Sensitivity Couplers. Nota Aplikacyjna firmy ADWEL International Canada, 2002.
- [4]. Blokhintsev, M. Golovkov, A. Golubev, C. Kane: Field Experiences on the Measurement of Partial Discharges on Rotating Equipment, IEEE PES’98, February 1-5, Tampa
- [5]. Golubev A, Paoletti G.: Partial Discharge Theory and Technologies related to Medium Voltage Electrical Equipment. 2000 IEEE. Reprinted, with permission, from Paper 99-25 presented at the IAS 34th Annual Meeting, Oct 3-7, ‘99, Phoenix, AZ.
- [6]. Kane C., Pozonsky J., Carney S., Blokhintsev I.: Advantages of Continuous Monitoring of Partial Discharges in Rotating Equipment and Switchgear. 2003 AISE Meeting, Pittsburgh, PA, Sept. 2003.
- [7]. Stone G.C., Boulter E.A., Culbert I., Dhirani H.: Electrical insulation for rotating machines. IEEE PRESS series on Power Engineering, USA, 2004.
- [8]. Szymaniec S.: Diagnostyka stanu izolacji uzwojeń i stanu łożysk silników indukcyjnych klatkowych w warunkach przemysłowej eksploatacji. Studia i Monografie z. 193, Wyd. Politech. Opolskiej, Opole 2006.
Typ dokumentu
Bibliografia
Identyfikator YADDA