Wear estimation criteria of turn to turn insulation with fuzzy voltage wave method
Języki publikacji
Abstrakty
Condition diagnostic of turn-to-turn insulation, using the method of fuzzy wave is based on breaking the passage of current in the circuit with tested coil or winding what generate a voltage wave. This voltage is exactly the same on each turn. The frequency of generated voltage depends solely on the parameters of the winding, not on the supply and parameters of insulation, what is described in [1] and [3]. Described method is a supplement of diagnostic method of main insulation with DC voltage, named method of prof. Glinka.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
65--67
Opis fizyczny
Bibliogr. 4 poz., rys., tab.
Bibliografia
- [1]. A.Decner, T. Glinka, A. Polak, kryteria oceny zużycia izolacji zwojowej Zeszyty Problemowe – Maszyny Elektryczne NR 81/2009 str.51.
- [2]. A. Decner, T. Glinka, A. Polak, J. Zawilak: Izolacja zwojowa – badania diagnostyczne. Przegląd Elektrotechniczny nr 12/2008.
- [3]. Zgłoszenie patentowe P 382388. Układ pomiarowy i metoda badania izolacji zwojowej. BOBRME Komel.
- [4]. Glinka T.: Klasyfikacja stopnia zużycia izolacji uzwojeń maszyn elektrycznych. Przegląd Elektrotechniczny PL ISSN 0033-2097 Nr 0/2004, str. 852-855.