Identyfikatory
Warianty tytułu
High voltage impulse method for diagnostic of rotating machins turn to turn insulation
Języki publikacji
Abstrakty
The paper presents high voltage insulation method for testing turn to turn insulation. Paper contain surge test theory and describes comparative character of this method. In the article has been presented test result from stators with damage turn to turn insulation as well from high voltage motors. The paper describes influence of the tester storage capacitor capacitance on the test results, base on turbo generator rotor tests.
Czasopismo
Rocznik
Tom
Strony
53--56
Opis fizyczny
Bibliogr. 4 poz., rys.
Twórcy
autor
- TurboCare Poland S.A., Lubliniec, wojciech.kandora@turbocare.pl
Bibliografia
- [1]. IEEE 522-2004 Guide for Testing Turn Insulation of Form-Wound Stator Coils for Alternating Current Electric Machines.
- [2]. EN 60034-18-32 Rotating electrical machines - Test procedures for form-wound windings.
- [3]. Kandora W., Smyczek A. – Diagnostyka izolacji zwojowej wirników turbogeneratorów. Nowoczesne metody pomiarowe. XVI Konferencja Energetyki.
- [4]. Wiedenbrug E. Frey, G. Wilson J. – Impulse testing and turn insulation deterioration in electric motors.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS2-0055-0065