PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Partial discharges of thermally aged insulation

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Częściowe uwalnianie ciepła w zużytej izolacji
Konferencja
Problemy eksploatacji maszyn i napędów elektrycznych (2009; Rytro, Polska)
Języki publikacji
EN
Abstrakty
EN
The working life of electrical machines is primary affected by the insulation system quality. Diagnostics methods help to understand the momentary state of insulation and to avoid the possible damage or breakdown of machines. Partial discharge testing belongs to one of the high applicable test method of insulating materials within electrical machines. The described experiment consists of laboratory thermal aging of insulation and consequently testing of partial discharges. The flat specimens of insulation were used for the partial discharge behavior recognition. The conductive rubber electrodes were used to avoid the gliding discharges on the surface of specimen. The trends of partial discharge main parameters are studied and described.
Rocznik
Tom
Strony
147--151
Opis fizyczny
Bibliogr. 11 poz., rys., tab.
Twórcy
autor
autor
autor
autor
  • University of West Bohemia, Faculty of Electrical Engineering Department of Technologies and Measurement, Univerzitní 8, 306 14 Pilsen, Czech Republic, pihera@ket.zcu.cz
Bibliografia
  • [1] MENTLÍK, V, at al: Výzkumný záměr MŠMT ČR MSM 4977751310 DIAGNOSTIKA INTERAKTIVNÍCH DĚJŮ V ELEKTROTECHNICE, Dílčí zpráva: INTERAKTIVNÍ DIAGNOSTIKA IZOLANTŮ, FEL ZČU v Plzni 2008.
  • [2] MENTLÍK, V.; PIHERA, J.; TRNKA, P.; TÁBOŘÍK, O. The influence of pulse stress on main-wall insulation of electrical rotating machines. In Maszyny Elektryczne. Katowice : Branżowy Ośrodek Badawczo Rozwojowy Maszyn Elektrycznych Komel,, 2007. s. 43-46. ISBN 0239-3646.
  • [3] MENTLÍK, V.; TRNKA, P.; PIHERA, J. Insulation Materials Under Electrical Pulse Stress. In Annals of DAAAM for 2007 & Proceedings of 18th International DAAAM Symposium. Vienna : DAAAM International, 2007. s. 447-448. ISBN 3-901509-58-5. ISSN 1726-9679.
  • [4] IEC Standard 270. Partial Discharge Measurement.
  • [5] MENTLÍK, V.; PIHERA, J.; TRNKA, P.; MARTÍNEK, P. Partial discharge potential free test methods. In 2006 annual report Conference on electrical insulation and dielectric phenomena. Kansas City : IEEE DEIS, 2006. s. 586-589. ISBN 1-4244-0547-5.
  • [6] MARTÍNEK, P.; LAURENC, J.; PIHERA, J. Typical Patterns of Partial Discharges Acquired by Measurements on Real Models of Cavity in Solid Dielectric and Instrument Transformers. In Third International Conference on Advances In Processing, Testing and Application of Dielectric Materials. Wroclaw, Poland : Oficyna Wydawnicza Politechniki Wroclawskiej, 2007. s. 245-249. ISSN 0324-9441.
  • [7] IEEE 1434-2000: IEEE Trial-Use Guide to the Measurement of Partial Discharges in Rotating Machinery.
  • [8] TUREČEK, O.; PIHERA, J. Realizace softwaru pro analýzu částečných výbojů ze záznamů ve formátu *.csv. In Diagnostika '07. Plzeň : Západočeská univerzita, 2007. s. 393-395. ISBN 978-80-7043-557-1.
  • [9] Hudon, C., Belec, M. “Partial discharge signal interpretation for generator diagnostics” in: IEEE Transactions on Dielectrics and Electrical Insulation, April 2005, Volume: 12 , Issue: 2, pages: 297-319.
  • [10] Russwum, D. “On-Site Partial Discharge Monitoring using the differential LEMKE PROBE LDP-5 and its accessories”, HV Testing, Monitoring and Diagnostic Workshop 2000.
  • [11] www.charleswater.co.uk.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS2-0051-0091
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.