PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Kontrola stanu izolacji blach maszyn elektrycznych w warunkach przemysłowych

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
EN
Industrial control of electrical machines core sheets insulation
Konferencja
Problemy eksploatacji maszyn i napędów elektrycznych (2009; Rytro, Polska)
Języki publikacji
PL
Abstrakty
EN
Core sheets insulations faults of electric machines result in eddy currents appearance. The currents flow is a reason of local temperature increasing which can cause wire and sheets insulation degradation. Visual diagnosis of core sheets insulation during the repair is not reliable. Traditional method of diagnosis, based on flux excitation by high intensity current and temperature increasing observation, is time consuming, not very reliable and inconvenient. Measurement of flux leakage on stator teeth surface is fast and reliable method of core sheets insulation diagnostic. This method doesn't require high intensity excitation current. Equipment offered on the market is very expensive and it is most dedicated to diagnose big synchronous generators. Authors invented, constructed and implemented original device dedicated to measure and diagnose of sheets insulations. Whole the system, with the special dedicated software was tested on special parts in laboratory and also in real industrial conditions. Paper shows principle of operation and results of using the system.
Rocznik
Tom
Strony
135--140
Opis fizyczny
Bibliogr. 7 poz., rys.
Twórcy
autor
autor
autor
Bibliografia
  • [1] David Bertenshaw : Improvements in Testing Stator Core Condition of Medium to Large Motors. Presented to CWIEME Conference, Berlin, July 2000
  • [2] Patent US 6469504 -Method and system for detecting core faults. Inventors: Kliman...... Date of filing: 28.07.2000
  • [3] EU Patent 1 318 411 -A method and apparatus for testing laminated cores of electrical machines . Inventor: Sutton, John. Date of filing: 02.12.2002
  • [4] Sang Bin Lee,Gerald B. Kliman, Manoj R. Shah, N. Kutty Nair and R. Mark Lusted: An Iron Core Probe Based Inter-Laminar Core Fault Detection Technique for Generator Stator Cores. IEEE TRANSACTIONS ON ENERGY CONVERSION, VOL. 20, NO. 2, JUNE 2005
  • [5] MOTOR CORE TESTER MCT 2 – ADWEL INTERNATIONAL LTD .
  • [6] DIGITAL EL-CID ™ MODEL 601 – ADWEL INTERNATIONAL LTD.
  • [7] Zgłoszenie patentowe nr P-386 432, Sposób i układ do wykrywania uszkodzeń obwodów magnetycznych maszyn elektrycznych, Data zgłoszenia 04.11.2008.