PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Badania wpływu zależności trwałości oraz napięcia zapłonu wyładowań niezupełnych izolacji przy napięciu impulsowym od jej wymiarów

Treść / Zawartość
Identyfikatory
Warianty tytułu
EN
Investigation of the influence of the interturn insulation size on the partial discharges inception voltage and lifetime
Konferencja
Problemy eksploatacji maszyn i napędów elektrycznych (2009; Rytro, Polska)
Języki publikacji
PL
Abstrakty
EN
The phenomena that appear in electrical motors insulation due to pulse voltage coming from inverters can depend on both the pulse voltage parameters as dimensions and characteristics of insulation. The result of investigation of dielectric properties as well durability and PDIV of various models of turn insulation (the twisted pairs and parallel wound helical coils with different number of coils) are presented in this paper. The “size effect” observed by group of Japan researchers under very short pulse duration have been not confirmed in our results under other pulse voltage. Because the size effect could be important for inverter-fed motors, the testing should be performed under pulse voltage that followed the real conditions. Probably the existing standard IEC 62068-1 specifies too extensive parameters of test pulse voltage.
Rocznik
Tom
Strony
67--71
Opis fizyczny
Bibliogr. 10 poz., rys., tab.
Twórcy
autor
autor
  • Instytut Elektrotechniki, Wrocław
Bibliografia
  • [1]. Morikawa M., Hayakawa N., Okubo H., Partial Discharge Inception and Degradation Characteristics of Inverter-Fed Motor Sample under Surge Voltage Condition, 2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, pp. 426-429
  • [2]. Hayakawa N., Okubo H., Partial discharge characteristics of inverter-fed motor coil samples under ac and surge voltage conditions, Electrical Insulation Magazine, IEEE, Volume 21, Issue 1, Jan.-Feb. 2005, pp. 5 – 10
  • [3]. Inuzuka K., Inano H., Hayakawa N., Hirose T., Hamaguchi M., Okubo H., Partial Discharge Characteristics of Nanocomposite Enameled Wire for Inverter-Fed Motor, 2006 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, pp. 594-597
  • [4]. Hayakawa N., Inano H., Inuzuka K., Morikawa M., Okubo H., Partial Discharge Propagation and Degradation Characteristics of Magnet Wire for Inverter-Fed Motor under Surge Voltage Application, 2006 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, p.p. 565-568
  • [5]. Hayakawa N., Morikawa M., Okubo H., Partial Discharge Inception and Propagation Characteristics of Magnet Wire for Inverter-fed Motor under Surge Voltage Application, IEEE Transactions on Dielectrics and Electrical Insulation Vol. 14, No. 1; February 2007, pp. 39-45
  • [6]. Okubo H., Lu Y., Hayakawa N., Partial Discharge Characteristics of invereter-fed motor coil samples under ac and surge voltage conditions, 2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, p.p. 589-592
  • [7]. Kimura K., Ushirone S., Fukushima T., Ohtsuka S., Hikita M., Partial Discharge Inception Voltage of Twisted Pair Samples under Long-Time Repetitive Bipolar Impulses, Conference Record of the 2004 IEEE International Symposium on Electrical Insulation, Indianapolis, IN USA, 19-22 September 2004, p.p. 192-195
  • [8]. Górecki L., Górnicka B., Degradacja izolacji międzyzwojowej silników pod wpływem narażeń pochodzących od przekształtników, IV Konferencja Naukowa Postępy, Jamrozowa Polana 2000, Prace Naukowe Instytutu Podstaw Elektrotechniki i Elektrotechnologii Polit. Wrocł. nr 37, seria: konferencje nr 12 s. 37-40
  • [9]. Górnicka B., Górecki L., Degradation of winding insulation due to power electronics devices in induction motors, Przegląd Elektrotechniczny APTADM’2001– Zeszyt Specjalny, s. 349-351
  • [10]. Górnicka B., Górecki L., Czołowska B., Zawadzka J.: Określenie napięcia zapłonu wyładowań koronowych izolacji międzyzwojowej przy zasilaniu napięciem impulsowym, Komel 2005, Maszyny elektryczne – Zeszyty problemowe Nr 72/2005, s. 29-32
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS2-0051-0046
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.