PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Fluctuations of the non-Newtonian fluid flow in a Kenics static mixer: An experimental study

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The measurements for a Kenics static mixer were carried out using Laser Doppler Anemometer (LDA). The test fluid was non-Newtonian solution of CMC, Blanose type 9H4. The velocity data inside the 5th Kenics insert were collected for the axial components at five levels of Reynolds number, Re = 20 ÷ 120. Velocity fluctuations were also analyzed in the frequency domain, after processing them with the help of the Fast Fourier Transform (FFT) procedure. The spectra of fluctuations provided information about level of the fluctuations in the observed range of Reynolds number. The obtained data were then also used to plot the velocity profiles for the fifth insert of the Kenics mixer. It was concluded that in the investigated range of Reynolds numbers (Re = 20 ÷ 120) a strong dependence of the velocity profiles and the flow fluctuations on Reynolds number was observed.
Rocznik
Strony
35--37
Opis fizyczny
Bibliogr. 7 poz., rys.
Twórcy
autor
  • Institute of Chemical Engineering and Environmental Protection Processes, Szczecin University of Technology, al. Piastów 42, 71-065 Szczecin, peryt@ps.pl
Bibliografia
  • 1. van Wageningen, W.F.C., Mudde, R.F. & van den Akker, H.E.E., Numerical investigation into mixing of particle-laden flows in a Kenics static mixer, 11th Europ. Conf. on Mixing, Bamberg, Germany, 2003, 137-144.
  • 2. Wadley, R. & Dawson, M.K., LIF measurements of blending in static mixers in the turbulent and transitional flow regimes, Chem. Eng. Sci., 2005, 60, 2469-2478. DOI: 10.1016/j.ces.2004.11.021
  • 3. Jaffer, A.A., Wood, P.E., Quantification of laminar mixing in the Kenics static mixer: an experimental study, Can. J. Chem. Eng., 1998, 76, 516-521.
  • 4. Adamiak, I. & Jaworski, Z., Badania eksperymentalne przepływu cieczy nieniutonowskiej w mieszalniku statycznym typu Kenics, Inż. Chem. i Proc., 2001, 22, 3B, 157.
  • 5. Adamiak, I., Badania anemometryczne i modelowanie numeryczne pól prędkości cieczy w mieszalnikach statycznych, PhD Thesis, Szczecin University of Technology, Szczecin 2003.
  • 6. Fang, J.Z. & Lee, D.J., Micromixing efficiency in static mixer, Chem. Eng. Sci., 2001, 56, 3797-3802.
  • 7. Li, H.Z., Fasol, C. & Choplin, L., Pressure drop of Newtonian and non-Newtonian fluids across a Sulzer SMX static mixer, Trans. IChemE, 1997, 75, Part A, 792-796.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS2-0049-0015
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.