PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Pomiary on-line stanu izolacji uzwojeń silników indukcyjnych wysokonapięciowych

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
EN
On-line measurement of the condition of winding insulation of high-voltage induction motors
Konferencja
Problemy eksploatacji maszyn i napędów elektrycznych (2007; Rytro, Polska)
Języki publikacji
PL
Abstrakty
EN
The article presents an industrial application of high voltage induction motor on-line measurement. The paper contains an analysis of different diagnostics methods. The results indicate that these on-line methods are both useful. Partial Discharge (PD) on-line measurement is a recognized testing method for identification of deterioration of stator winding insulation of high voltage rotating machines such as hydraulic generators, high-speed turbine generators and large motors.
Rocznik
Tom
Strony
89--94
Opis fizyczny
Bibliogr. 16 poz., rys., tab.
Twórcy
autor
  • Politechnika Opolska, Instytut Układów Elektromechanicznych i Elektroniki Przemysłowej, 45-951 Opole, ul. Luboszycka 7, slawszym@po.opole.pl
Bibliografia
  • [1]. ADWEL: PD monitoring. Nota Aplikacyjna 2003.
  • [2]. Bertenshaw D., Sasic M: On-line Partial Discharge Monitoring on MV motors-Casestudies on Improved Sensitivity Couplers. Nota aplikacyjna firmy ADWEL International Canada, 2002.
  • [3]. Blokhintsev, M. Golovkov, A. Golubev, C. Kane: Field Experiences on the Measurement of Partial Discharges on Rotating Equipment, IEEE PES'98, February 1-5, Tampa
  • [4]. Drak B.: Zagadnienia elektromechaniczne czół uzwojeń stojanów maszyn elektrycznych dużej mocy prądu przemiennego. Monografia, Wyd. Politechnika Śląska, Zeszyty Naukowe Elektryka, zeszyt nr 163, Gliwice, 1998.
  • [5]. Florkowska B., Florkowski M., Włodek R., Zydroń P.: Mechanizmy, pomiary i analiza wyładowań niezupełnych w diagnostyce układów izolacyjnych wysokiego napięcia. Wyd. IPPT PAN, Warszawa 2001.
  • [6]. Glinka T.: Badania diagnostyczne maszyn elektrycznych w przemyśle. Wyd. BOBRME, Katowice 1998.
  • [7]. Holboll J.T., Henriksen. M.: Frequency-dependent PD pulse distortion in rotating machines. IEEE International Symposium on Electrical Insulation, Montreal, Canada, June 16-19, 1996. pp. 192-196.
  • [8]. Holboll J. T., Henriksen M., Jensen A.: Motor insulation diagnostics by high frequency PD detection. Asnaes Power Station SK Power Company, Kalundborg, Denmark 1994.
  • [9]. Hoof, M., Lanz, S.. PD Diagnostics on Rotating Machines - Possibilities and Limitations. Electrical Insulation Conference, Cincinnati, OH, October 26-28, 1999.
  • [10]. Kane C., Pozonsky J., Carney S., Blokhintsev I.: Advantages of Continuous Monitoring of Partial Discharges in Rotating Equipment and Switchgear. 2003 AISE Meeting, Pittsburgh, PA, September 2003.
  • [11]. Kouadria D., Ryder D. M., Miller R., Thompson A. I.: On-site application of a computer aided system for PD measurement and interpretation in electrical machines. 9th Intern. Conf. on Condition Monitoring and Diagnostic Engineering and Management (COMADEM), Sheffield University, UK 1996.
  • [12]. Sasic M., Bertenshaw D.: On-line Partial Discharge Monitoring on MV Motors -Case Studies on Improved Sensitivity Couplers and Interpretation Methods, SDEMPED 2001, ITALY 1-3 September 2001 pp. 1-5
  • [13]. Sasic M.: Partial discharge measurement on rotating machines. 9th National Congress of Electric Rotating Machinery September 29 to October 2, 1999, Veracruz, Mexico.
  • [14]. Stone G.C., Boulter E.A., Culbert I., Dhirani H.: Electrical insulation for rotating machines. IEEE PRESS series on Power Engineering, USA, 2004.
  • [15]. Szymaniec S.: Diagnostyka stanu izolacji uzwojeń i stanu łożysk silników indukcyjnych klatkowych w warunkach przemysłowej eksploatacji. Studia i Monografie z. 193, Wyd. Politech. Opolskiej, Opole 2006.
  • [16]. Warren V.: Partial Discharge Testing: A Progress Report. Iris Rotating Machinery Conference, USA, Santa Monica, June 2003, pp. 1-13.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS2-0043-0022
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.