This article presents an analysis of how pulses in the long two-conductor coupled lines with conductor screened interact mutually. The interaction of pulses appears in those places of the line, where there is a change of wave impedance causing a change in reflection coefficient for pulses moving along the line. An exemplary analysis is performed for a homogenous lossless line at its starting and terminal points. The results of analysis are analytical expressions describing quantitative interactions of pulses. The expressions are verified both by computer simulation and by measurements of the real line. There has been performed the analysis of influence of the resistances with which the terminal points of the line are loaded onto the amplitude value of the pulses registered at the starting point of the line. The new method and the new system of measurements of pulses have been proposed that minimize the interaction of pulses at the starting point of the line, disadvantageous for the process of fault location by using pulse method.
PL
W artykule przedstawiona jest analiza wzajemnego oddziaływania impulsów na siebie w liniach długich sprzężonych dwużyłowych z jednym wspólnym ekranem. Oddziaływanie impulsów występuje w miejscach, w których następuje zmiana impedancji falowej żył powodująca zmianę współczynników odbicia. Przykładowa analiza oddziaływania impulsów przeprowadzona jest dla linii jednorodnej bezstratnej. Wynikiem analizy są wyrażenia opisujące ilościowe oddziaływanie impulsów na siebie, które zostały następnie zweryfikowane w drodze symulacji komputerowej i w pomiarach wykonanych dla linii rzeczywistej. Przeprowadzono analizę wpływu wartości rezystancji obciążających końce żył na wartość amplitudy impulsów rejestrowanych na początku linii. Zaproponowano nowy sposób i układ do pomiaru impulsów minimalizujący oddziaływanie impulsów na siebie na początku linii niekorzystne dla procesu lokalizacji uszkodzeń metodami impulsowymi.
Rocznik
Strony
301--312
Opis fizyczny
Bibliogr. 9 poz., rys.
Twórcy
  • Faculty of Electrical Engineering, Automatic Control and Computer Science, Opole University of Technology, wtar@po.opole.pl
Bibliografia
  • 1. Hayden L.A., Tripathi V.K.: Characterization of Differential Interconnects from TDR Measurements. IEEE Trans. On Microwave Theory and Techniques, Vol. 42, Sept. 1994, pp. 1737-1743.
  • 2. Ofranidis S.J.: Coupled lines. Electromagnetic Waves & Antennas. Feb. 28, 2004. pp. 335-353.
  • 3. Retting D., Tripathi V.K.: A SPICE Model for Multiple Coupled Microstrips and Other Transmission lines. IEEE MTT-S Internal Microwave Symposium Digest, 1985.
  • 4. Roychwdhury H., Pederson K.: Efficient Transient Simulation of Lossy Interconnect. Design Automation Conference, 28th ACM/IEEE, 1991, pp. 740-745.
  • 5. TarczyńskiW.: Pulses method in location of faults in power transmission lines. Scientific papers. Issues of the Opole University of Technology, Z-191, 2006.
  • 6. Tarczyński W.: Conditions of pulse propagation in coupled lines. 10th Conference of Science and Technique, Applications of Computers in Electrical Engineering, Poznan, 18-20th, April 2005, pp. 195-196.
  • 7. TarczyńskiW.: Conditions of pulse propagation in coupled lines. Scientific papers of the Poznan University of Technology. No 50, 2006, pp. 19-32.
  • 8. TarczyńskiW.: Generator of short pulses especially for testing coupled lines. Patent application No. P378453.
  • 9. Tarczyński W.: Method of testing coupled lines. Patent application, No. P378452.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPS2-0040-0026
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.