PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
Tytuł artykułu

LA-ICP-MS investigations of a long-term effect of indoor air pollution on paper

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Badanie wpływu długoterminowej ekspozycji papieru na zanieczyszczone powietrze metodą LA-ICP-MS
Języki publikacji
EN
Abstrakty
EN
Systematic research has shown that the state of librarian and archival collections depends on the quality of storage conditions. Therefore, it was interesting to learn about the long-term effect of the indoor air pollution on the collection of the National Library in Warsaw (Poland). Information about deposition of inorganic pollutants on paper was collected for indicators, which had been stored for 12 years (1990-2002) in the selected storage rooms of the Krasiński Palace (Warsaw, Poland). Inductively coupled plasma mass spectrometry (1CP-MS) was vised to study the change of the indicator's elemental composition after the long-term exposition to the librarian indoor environment; all indicators were examined with respect to the possible deposition of metals. Bulk concentration of selected elements in the paper indicators were determined by 1CP-MS after microwave digestion of the samples, whereas LA-ICP-MS was used to evaluate deposition of selected elements at the surface and possible migration into sub-surface domains of paper indicators.
PL
Celem pracy było sprawdzenie wpływu zanieczyszczenia środowiska wewnątrz Biblioteki Narodowej w Warszawie na zachowanie tamtejszych zbiorów. Ocena zmian składu pierwiastkowego papieru wywołanego długotrwałym, 12-letnim magazynowaniem w jednym z budynków bibliotecznych była możliwa dzięki zastosowaniu wskaźników o znanym składzie chemicznym. Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP—MS) została wykorzystana podczas analizy składu pierwiastkowego wskaźników przchowywanych w wybranych pomieszczeniach Pałacu Krasińskich w Warszawie w latach 1990-2002. Całkowite stężenie wybranych pierwiastków w próbkach papieru pobranych ze wskaźników oznaczono metodą ICP-MS po mineralizacji mikrofalowej. Sposób rozmieszczenia tych pierwiastków na powierzchni oraz ocena migracji do podpo-wierzchniowych obszarów analizowanych wskaźników zostały ocenione za pomocą metody LA-ICP-MS.
Czasopismo
Rocznik
Strony
1253--1264
Opis fizyczny
Bibliogr. 27 poz.
Twórcy
autor
autor
autor
autor
autor
Bibliografia
  • 1. Johansson A., Air Pollution and Paper Deterioration. Causes and Remedies, Ph.D. thesis Göteborg University, Department of Chemistry 2000.
  • 2. Pavlogeorgatos G., Building Environ., 38, 1457 (2003).
  • 3. Wilson W.K., Environmental Guidelines for the Storage of Paper Records (NISO-TR01-1995), Bethesda, MD: NISO Press, 1995.
  • 4. Strlic M. and Kolar J., Postpr. 5th Eur. Conf. Cultural Herit. Res., Cracow, Poland, 16.18 May, 79 (2002).
  • 5. Ryhl-Svendsen M., Padfield T., Smith V.A. and De Santis F., Healthy Buildings, 278 (2003).
  • 6. Odlyha M., Foster G.M., Cohen N.S., Sitwell C. and Bullock L., J. Environ. Monit., 2, 127 (2000).
  • 7. Valentin N., http://www.getty.edu/conservation/science/climate/paper_valentin.pdf (1998).
  • 8. Maggi O., Persiani A.M., Gallo F., Valenti P., Pasquariello G., Sclocchi M.C. and Scorrano M., Aerobiologia, 16, 429 (2000).
  • 9. Vallius M., Characteristics and Sources of Fine Particulate Matter in Urban Air, National Public Health Institute, Department of Environmental Health Kuopio, Finland 2005.
  • 10. Nasir Z.A. and Colbeck I., J. Environ. Monit., 11, 1140 (2009).
  • 11. Walker S.E., Slordal L.H., Guerreiro C., Gram F. and Gronskei K.E., J. Environ. Monit., 1, 321 (1999).
  • 12. Brzozowska-Jabłońska M., Biblioteka Muzealnictwa i Ochrony Zabytków serie B, 24, 115 (1969).
  • 13. Havermans J. and Porck H., La Conservation ARSAG, Paris 173 (2002).
  • 14. Havermans J. and Porck H., Restaurator, 16/4, 209 (1995).
  • 15. Johansson A., Kolseth P. and Lindqvist O., Restaurator, 21/3, 117 (2000).
  • 16. Adriaens A., Spectrochim. Acta B, 60, 1503 (2005).
  • 17. Calvini P. and Silveira M., e-Preservation Sci., 5, 1 (2008).
  • 18. Gysels K., Deutsh F. and Van-Grieken R., Atmospheric Environ., 36, 4103 (2002).
  • 19. Havermans J.B.G.A., Environmental Influences on the Deterioration of Paper, Barjesteh, Meeuwes&Co, Rotterdam, 43 (1995).
  • 20. Keheyan Y. and Giulianelli L., e-Preservation Sci., 3, 5 (2008).
  • 21. Rutten F.J.M., Roe M.J., Henderson J. and Briggs D., Appl.Surface Sci., 252/19, 7124 (2006).
  • 22. Durrant S.F., J. Anal. At. Spectrom., 14, 1385 (1999).
  • 23. Wagner B. and Bulska E., J. Anal. At. Spectrom., 19, 1325(2004).
  • 24. Wagner B., Bulska E. and Sobucki W., J. Cultural Herit., 9, 60 (2008).
  • 25. [Schreiner M., Strliè M. and Salimbeni R., Eds.], COST office http://www.science4heritage.org/COSTG7/booklet/ (2008).
  • 26. http://www.igipz.pan.pl/geoekoklimat/Warszawy/klimat/klimat.html.
  • 27. Wagner B., Garbos S., Bulska E. and Hulanicki A., Spectrochim. Acta B, 54, 797 (1999).