Pośrednia metod oznaczania jonów cyjankowych za pomocą FIA-FAAS z użyciem kolumny z wypełnieniem Ag3PO4 : eliminacja interferencji pochodzących od jonów fosforanowych(V) w oznaczaniu srebra za pomocą FAAS
Języki publikacji
Abstrakty
Anew, simple and single-line flow injection system procedure for indirect determination of cyanide has been developed. The method was based on the insertion of" aqueous cyanide solutions into an online silver phosphate packed column (15% m/m suspended on silica gel beads). The carrier stream was an alkaline solution containing 0.02 mol L-1 calcium ions as the releasing agent. The cluate contained silver cyanide complexes as the analytc: they were produced in the reaction between silver phosphate and cyanide and measured by flame atomic absorption spectrometry. The absorbance was proportional to the concentration of cyanide in the sample. Under optimum conditions, the linear range, detection limit and sampling rale of up to 18 mgL-1, 0.04 mg L-1and 220 h-1, respectively, were obtained. The method is suitable for determination of cyanide in industrial waste waters with a relative standard deviation better than 1.07%.
Opracowano nową, prostą metodę pośredniego oznaczania jonów cyjankowych z zastosowaniem jednokanatowego układu analizy wstrzykowo-przepływowej. Postępowanie polega na wprowadzaniu wodnego roztworu jonów cyjankowych na kolumnę wypełnioną foslbranem(V) srebra (15% m/m, osadzonym na podłożu z dwutlenku krzemu). W charakterze roztworu nośnego stosowano alkaliczny roztwór jonów wapnia o stężeniu ; 0,02 mol L-1, spełniających rolę czynnika uwalniającego. Eluat zawierał cyjankowe kompleksy srebra powstające w reakcji pomiędzy fosforanem(V) srebra i jonami cyjankowymi; były one oznaczane za pomocąpłomieniowej atomowej spektrometrii absorpcyjnej. Mierzona wartość absorbancji była proporcjonalna do stężenia jonów cyjankowych w analizowanej
Wydawca
Czasopismo
Rocznik
Tom
Strony
895--906
Opis fizyczny
Bibliogr. 34 poz.
Twórcy
autor
autor
autor
- Analytical Research Laboratory, Department of Chemistry, University of Sistan & Baluchestan, Zahedan, Iran, P.O. Box 98155-147, mnoroozifar@chem.usb.ac.ir
Bibliografia
- 1. Ishli A., Seno H., Suzuki K.W. and Suzuki O., Anal. Chem., 70, 4873 (1998).
- 2. Adhoum N. and Monser L., Chem. Eng. Process, 41, 17 (2002).
- 3. Seto Y., Anal. Chem., 74, 134A (2002).
- 4. US EPA Fed Reg 63 (170), FR 44511, (1998).
- 5. Bohrer D., Nascimento P.C., Garcia S., Seibert E. and Machado L., Fresenius J. Anal. Chem., 361, 780 (1998).
- 6. Sulistyarti H., Cardwell T.J., Castro M.D.L. and Kolev S.D., Anal. Chim. Acta., 390, 133 (1999).
- 7. Williams W.J., Handbook of Anion Determination, Butterworth & Co, UK 1979.
- 8. Themelis D.G. and Tzanavaras P.D., Anal. Chim. Acta., 452, 295 (2002).
- 9. Nagaraja P., Hemantha M.S., Yathirajan H.S. and Prakash J.S., Anal. Sci., 18, 1027 (2002).
- 10. Safavi A., Maleki N. and Shahbaazi H.R., Anal. Chim. Acta., 503, 213 (2004).
- 11. Abbaspour A., Asadi M., Ghaffarinejad A. and Safaei E., Talanta, 66, 931 (2005).
- 12. Smith M.H. and Cass E.G., Anal. Chem., 62, 2429 (1990).
- 14. Utley D., Analyst, 115, 1239 (1990).
- 15. Jackson P.E., Trac-Trend Anal. Chem., 20, 320, (2001).
- 16. Aguilar M., Farran A. and Marti V., J. Chromatogr. A, 778, 397 (1997).
- 17. Nonomura M., Anal. Chem., 59, 2073 (1987).
- 18. Curtis A.J., Grayless C.C. and Fall R., Analyst, 127, 1446 (2002).
- 19. Mirmohseni A. and Alipour A., Sens Actuators B, 84, 245 (2002).
- 20. Lin Y., Rocklin R.D., Joyce R. J. and Doyle M.J., Anal. Chem., 62, 766 (1990).
- 21. Miralles E., Prat D., Compano R. and Granados M., Analyst, 123, 217 (1998).
- 22. Recalde-Ruiz D.L., Andres-Garcia E. and Diaz-Garcia M.E., Analyst, 125, 2100 (2000).
- 23. Ipatov A., Ivanov M., Makarychev-Mikhailov S., Kolodnikov V., Legin A. and Vlasov Y., Talanta, 58, 1071 (2002).
- 24. Weinberg H.S. and Cook S.J., Anal. Chem., 74, 6055 (2002).
- 25. Marin M.A.B., Silva R.C., Lehmkuhl A., Silva J.B., Ganzarolli E.M. and Queiroz R.R.U., Química Nova, 23, 23 (2000).
- 26. Haj-Hussein A.T., Talanta, 44, 545 (1997).
- 27. Hangos-Mahr M., Pungor E. and Kuznecov V., Anal. Chim. Acta, 178, 289 (1985).
- 28. Haj-Hussein A.T., Christian G.D. and Ruzicka J., Anal. Chem., 58, 38 (1986).
- 29. Gomez A.V.L. and Calatayud J.M., Analyst, 123, 2103 (1998).
- 30. Noroozifar M., Khorasani-Motlagh M. and Hosseini S.N., Anal. Chim. Acta, 528, 269 (2005).
- 31. Noroozifar M., Khorasani-Motlagh M. and Hosseini S.N., Chem. Anal. (Warsaw), 51, 285 (2006).
- 32. Noroozifar M., Khorasani-Motlagh M. and Zare-Dorabei R., Talanta, 72, 1773 (2007).
- 33. Ravindranath B., Principles and practice of chromatography, John Wiley and Sons, New York 1989.
- 34. Miller J.C., Statistics for analytical chemistry, in: Miller J.N., John Wiley and Sons, New York 1988.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP2-0003-0006