PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Multi-walled carbons nanotubes modified with N-phenyl-1,2-hydrazinedicarbothioamide as a sorbent for separation and preconcentration of trace amounts of cadmium

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Carbon nanotubes (CNTs) are considered a new allotropic form of carbon. They are fascinating in many application fields. In this work we studied the analytical potential of modified multi-walled carbon nanotubes (MMWCNTs) as a sorbent for separation and precon-centration of trace amounts of cadmium ions, followed by their flame atomic absorption spectrometric determination in water samples. Multi-walled carbon nanotubes (MWCNTs) were oxidized with 4 mol L-1 HNO-1 and modified with N-phenyl-1,2-hydrazinedicarbothio-amide. Then, MMWCNTs were used as a sorbent for preconcentration of Cd+2. Under optimum experimental conditions flame atomic absorption spectrometric analysis was performed. Cadmium ions were quantitatively retained by MMWCNTs in the pH rang of 5-7.5. Elution was carried out with 5.0 mL of 0. l mol L-1 of HNO3. The flow rate of the sample solution was set at 2 mL min-1. The calibration plot was linear in the concentration range of cadmium ion in the final solution of 20-3500 ng mL-1 with a correlation factor of 0.9993. Detection limit in the final solution was 1.81 ng mL-1 with enrichment factor of 90. The effects of the experimental parameters on results of preconcentration and determination of cadmium, including sample pH, flow rates of sample and eluent solutions, type of eluent, breakthrough volume, and interference ions were studied. The method was successfully applied to the determination of trace amounts of Cd2+ in different samples.
PL
Nanorurki węglowe (CNTs) uważane za nową odmianę węgla stwarzają fascynujące, nowe możliwości zastosowań. W niniejszej pracy badano potencjalne możliwości modyfikowanych wielościanowych nanorurek węglowych (MMWCNTs) w charakterze sorbentu do wydzielania i zatężania śladowych ilości jonów kadmowych do ich następnego oznaczania w próbkach wody za pomocą płomieniowej absorpcyjnej spektrometrii atomowej. Wielościanowe nanorurki węglowe (MWCNTs) utleniano za pomocą 4 mol L-1 HNO3, modyfikowano za pomocąN-fenylo-l,2-hydrazynodikarbotioamidu, anastępnie otrzymany MMWCNTs stosowano jako sorbent do zatężaniajonów Cd+2. Oznaczenia kadmu za pomocą płomieniowej atomowej spektrometrii absorpcyjnej prowadzono w optymalnych warunkach ustalonych eksperymentalnie. Kadm jest ilościowo zatrzymywany przez MMWCNTs w zakresie pH 5-7,5. Elucję prowadzono za pomocą 5,0 mL 0,1 mol L-1 HNO,. Natężenie przepływu ustalono na poziomie 2 mL min-1. Krzywa kalibracyjna była liniowa w zakresie stężeń 20-3500 ng mL-1 ze współczynnikiem korelacji odnoszącym się do końcowego roztworu: 0,9993. Granica wykrywalności wynosiła 1,81 ng mL-1 a współczynnik wzbogacenia: 90. Badano wpływ różnych warunków doświadczalnych takich jak: pH próbki, natężenie przepływu próbki i eluentu, rodzaj eluentu, objętość do przebicia i wpływ jonów przeszkadzających na zatężanie i oznaczanie śladowych ilości kadmu. Metodę zastosowano z powodzeniem do oznaczania śladowych zawartości kadmu w różnego rodzaju próbkach.
Czasopismo
Rocznik
Strony
459--469
Opis fizyczny
Bibliogr. 39 poz.
Twórcy
autor
autor
autor
Bibliografia
  • 1. Dresselhaus M.S, Dresselhaus G. and Avouris P., Carbon Nanotubes: Synthesis, Structure, Properties, and Applications, Springer (2001).
  • 2. Trojanowicz M., Trends in Analytical Chemistry, 25, 480 (2006).
  • 3. Li Y.H., Wang S., Luan Z., Ding J., Xu C. and Wu, D., Carbon, 41, 1057 (2003).
  • 4. Grobert N. Materials Today, 10, 28 (2007).
  • 5. He J.B., Chen C.L. and. Liu J.H., Sens. Actuators B, 99, 1 (2004).
  • 6. Zeng B.Z. and Huang F., Talanta, 64, 380 (2004)
  • 7. Yang C.H., Microchim. Acta, 148, 87 (2004).
  • 8. Wang J., Analyst, 13, 421 (2005).
  • 9. Oehme F.W., Toxicity of Heavy Metals in the Envirnment, Marcel Decker, New York (1978).
  • 10. Li L., Hu B., Xia L. and Jiang Z., Talanta, 70, 468 (2006).
  • 11. Mikuła B. and Puzio B., Talanta, 71, 136 (2007).
  • 12. Fan Z. and Zhou W., Spectrochim. Acta Part B, 61, 870 (2006).
  • 13. Melek E., Tuzen M. and Soylak M., Anal. Chim. Acta, 578, 213 (2006).
  • 14. Bonfil Y., Kirowa-Eisner E., Anal. Chim. Acta, 457, 285 (2002).
  • 15. Raimundo I.M. and Narayanaswamy R., Sens. Actuators. B. Chem., 90, 189 (2003).
  • 16. Yu M.Q., Liu G.O. and Jin Q., Talanta, 30, 265 (1983).
  • 17. Vanderborght B.M. and Vangrieken R.E., Anal. Chem., 40, 311 (1997).
  • 18. Zhou Q., Wang W. and Xiao J., Anal. Chim. Acta, 559, 200 (2006).
  • 19. Soylak M. and Elci L., Int. J. Environ. Anal. Chem., 66, 51 (1997).
  • 20. Taher M.A., Talanta, 52, 181 (2000).
  • 21. Taher M.A., Rezaeipour E. and Afzali D., Talanta, 63, 797 (2004).
  • 22. Pena Y.P., Lopez W., Burguera J.L., Burguera M., Gallignani M., Brunetto R., Carrero P., Rondon C. and Imbert, F., Anal. Chim. Acta, 403, 249 (2000).
  • 23. Afzali D., Mostafavi A., Taher M.A. and Moradian A., Talanta, 71, 971 (2007).
  • 24. Afzali D., Mostafavi A. and Taher M.A., Anal. Sci., 22, 849 (2006).
  • 25. Afzali D., Mostafavi A., Taher M.A. and Mohammadi S.Z.M., Talanta, 65, 476 (2005).
  • 26. Zhang W., Wan F., Xie Y„ Gu J., Wang J., Yamamoto K. and Jin L., Anal. Chim. Acta, 512, 207 (2004).
  • 27. Barbosa A.F., Segatelli M.G., Pereira A.C., Santos A.S., Kubota L.T., Luccas P.O. and Tarley C.R.T., Talanta, 71, 1512 (2007).
  • 28. Lu C. and Chiu H., Chem. Eng. Sci., 61, 1138 (2006).
  • 29. Li Y.H., Wang S., Luan Z., Ding J., Xu C. and Wu D., Carbon, 41, 1057 (2003).
  • 30. Xu J., Wang Y., Xian Y., Jin L. and Tanaka K., Talanta, 60, 1123 (2003).
  • 31. Zhou Q., Wang W. and Xia J., Anal. Chim. Acta, 559, 200, (2006).
  • 32. Mester Z. and Sturgeon R., Sample Preparation for Trace Element Analysis, Amsterdam, Netherlands, Elsevier (2003).
  • 33. Gama E.M., Lima A.S. and Lemos V.A., J. Hazard. Mater. B, 136, 757 (2006).
  • 34. Prasad K., Gopikrishna P., Kala R., Raob T.P. and Naidu G.R.K., Talanta, 69, 9838 (2006).
  • 35. Biurrun M.C.Y., Perez S.C. and Barinaga A.M., Anal. Chim. Acta, 533, 51 (2005).
  • 36. Tarley C.R.T., Ferreira S.L.C. and Arruda M.A.Z., Michrochem. J., 77, 163 (2004).
  • 37. Wang Z.H., Zhang Z.P., Wang Z.P., Liu L.W. and Yan X.P., Anal. Chim. Acta, 514, 151 (2004).
  • 38. Pourreza N. and Zavvar Mousavi H., Anal. Chim. Acta, 503, 279 (2004).
  • 39. Cerutti S., Silva M.F., Gasquez J.A., Olsina R.A. and Martinez L.D., Spectrochim. Acta B, 58, 43 (2003).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP2-0002-0088
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.