A simple disposable conducting polymer - polyaniline based system for the alkaline phos- 1 phatase activity determination either in potentiometric or UV-VIS spectrophotometric setup is described. The conducting polymer was placed on a plastic polyacetate support by disper-; sing polyaniline nanoparticles. The detection method used is based on the enzymatic hydrolysis of monofluorophosphate which leads to a decrease of sample pH and finally results in a measurable change in the polyaniline electrode potential or the absorption spectra of the polymer. Both techniques offer similar sensitivity, but for the potentiometric mode a lower detection limit was obtained; it was close to 30 U L-1 (below 1 mgL-1).
PL
Opisano proste czujniki jednorazowego użytku, wykorzystujące polimer przewodzący - polianilinę, umożliwiające oznaczanie fosfatazy alkalicznej techniką potencjometrii i spektrofotometrii UV-VIS. Polimer przewodzący naniesiono z zawiesiny nanocząstek polianiliny na podłoże z folii polioctanowej. Metoda detekcji wykorzystuje enzymatyczną hydrolizę anionów monofluorofosforanowych, prowadzącą do obniżenia pH i w rezultacie do mierzalnej zmiany potencjału elektrody polianilinowej lub zmiany widma absorpcyjnego polimeru. Obie techniki zapewniaj ą podobną czułość, lecz dla metody potencjometrycznej uzyskano niższą granicę wykrywalności, bliską 30 UL-1 (poniżej l mgL-1).
Czasopismo
Rocznik
Strony
415--425
Opis fizyczny
Bibliogr. 22 poz.
Twórcy
autor
autor
  • University of Warsaw, Department of Chemistry, ul. Pasteura 1, 02-093 Warszawa
Bibliografia
  • 1. Vidal J.C., Garcia-Ruiz E. and Castillo J.R., Microchim. Acta, 143, 93 (2003).
  • 2. Malhotra B.D., Chaubey A. and Singh S.P., Anal. Chim. Acta, 578, 59 (2006).
  • 3. Genies E.M. and Tsintavis C., J. Electroanal. Chem., 195, 109 (1985).
  • 4. Lindfors T. and Ivaska A., J. Electroanal. Chem., 531, 43 (2002).
  • 5. Karyakin A.A., Bobrova O.A., Lukachova L.V. and Karyakina E.E., Sens. Actuators B, 33, 34 (1996).
  • 6. Ge Z., Brown C.W., Sun L. and Yang S.C., Anal. Chem., 65, 2335 (1993).
  • 7. Pringsheim E., Terpetschnig E. and Wolfbeis O.S., Anal. Chim. Acta, 357, 247 (1997).
  • 8. Lindfors T., Harju L. and Ivaska A., Anal. Chem., 78, 3019 (2006).
  • 9. Michalska A., Wojciechowski M., Jędral W., Bulska E. and Maksymiuk K., J. Solid State Electrochem., 13, 99 (2009).
  • 10. Michalska A. and Maksymiuk K., Anal. Chim. Acta, 523, 97 (2004).
  • 11. Michalska A., Ocypa M. and Maksymiuk K., Electroanalysis, 17, 327 (2005).
  • 12. Kisiel A., Michalska A. and Maksymiuk K., Bioelectrochemistry, 71, 75 (2007).
  • 13. Mac Diarmid A.G., Synth. Met., 125, 11 (2001).
  • 14. Koncki R., Trends Anal. Chem., 27, 304 (2008).
  • 15. Tietz N.W. and Shuey D.F., Clin. Chem., 32, 470 (1986).
  • 16. Evangelista R.A., Pollak A. and Templeton E.F., Anal. Biochem., 197, 213 (1991).
  • 17. Zhu X. and Jiang Ch., Clin. Chim. Acta, 377, 150 (2007).
  • 18. Koncki R., Rozum B. and Głąb S., Talanta, 68, 1020 (2006).
  • 19. Koncki R., Ogończyk D. and Głąb S., Anal. Chim. Acta, 538, 257 (2005).
  • 20. Ogończyk D. and Koncki R., Anal. Chim. Acta, 600, 194 (2007).
  • 21. Vazquez M., Danielsson P., Bobacka J., Lewenstam A. and Ivaska A., Sens. Actuators B, 97, 182 (2004).
  • 22. Bishop M.L., Fody E.P. and Schoeff L., Clinical chemistry. Principles, procedures, correlations, Lippincott Williams & Wilkins 2005.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP2-0002-0085
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.