PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

In-situ plated lead film electrode for determination of glipizide in pharmaceutical formulation and human urine

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Oznaczanie glipizidu w preparacie farmaceutycznym i w ludzkim moczu za pomocą błonkowej elektrody ołowiowej tworzonej in situ
Języki publikacji
EN
Abstrakty
EN
In this paper, electrochemical behavior of glipizide at an in-situ plated lead film electrode has been studied. A simple and precise square wave adsorptive stripping voltammetric procedure for quantification of glipizide with detection limit of 2.5 x 10-9 mol L-1 has been described. Relative standard deviation for determination of 5 x 10-9mol L-1 glipizide was 3.5%. The measurements were carried out in non-deoxygentaed solutions. The proposed procedure has been successfully applied to quantification of glipizide in its pharmaceutical formulations and human urine samples.
PL
W pracy zbadano elektrochemiczne zachowanie się glipizidu na tworzonej in-situ błonkowej elektrodzie ołowiowej. Opisano prostą i precyzyjną procedurę oznaczania glipizidu z wykorzystaniem adsorpcyjnej woltamperometrii stripingowej i techniki fali prostokątnej, o granicy wykrywalności równej 2,5 x 10-10mol L-1. Względne odchylenie standardowe oznaczania glipizidu o stężeniu 5 x 10-9 mol L-1wynosiło 3,5%. Pomiary przeprowadzono w roztworach nieodtlenionych. Zaprezentowana procedura została zastosowana do oznaczania glipizidu ,, w preparatach farmaceutycznych i próbkach ludzkiego moczu.
Czasopismo
Rocznik
Strony
31--41
Opis fizyczny
Bibliogr. 22 poz.
Twórcy
autor
autor
Bibliografia
  • 1. Lebovitz H E., Pharmacotherapy, 5, 63 (1985).
  • 2. Wahlin-Boll E. and Melander A., J. Chromatogr., 164, 541 (1979).
  • 3. Emilsson H„ J. Chromatogr Biomed. Anal., 421, 319 (1987).
  • 4. Dubey A. and Shukla I.C., J. Indian Chem. Soc., 81, 84 (2004).
  • 5. Abu-Ruz S . Millership J.and McElnay J., J. Chromatogr. B, 817, 277 (2005).
  • 6. Venkatcsh P., HarisudhanT„ Choudhury II., Mullangi R. and Srinivas N R., Biomed. Chromatogr., 20, 1043(2006).
  • 7. Ho E.N.M., Yiu K.C.H . Wan T.S.M., Stewart B.D. and Watkins K.L.. J. Chromatogr B, 811 65 (2004).
  • 8 Lin Z.P.J.. Desai-Krieger D. and Shum L., J. C.hromalogr. B, 801, 265 (2004).
  • 9. El-Kousy N.M.. Mikrochem. Acta, 128, 65 (1998).
  • 10.Strausbauch M.A., Xu S.J., Ferguson J.E., Nunez M.E.. Machacek D., Lawson G M . Wettstein P.J. and Landers J.P.,J. Chromatogr. A, 717, 279 (1995).
  • 11.Roche M.E., Oda R.P.. Lawson G.M and Landers J.P„Electrophoresis, 18, 1865 (1997).
  • 12.Radi A., Wahdan T. and Abd El-Ghany N., Chem. Anal. (Warsaw), 49, 627 (2004).
  • 13.Ghoneim E M., El-Attar M.A., Hammam E. and Khashaba P.Y.,7. Pharmaceut. Biomed., 43, 1465 (2007).
  • 14.Korolczuk M., Tyszczuk K. and Grabarczyk M., Electrochem. Commun, 7, 1185 (2005)
  • 15.Grabarczyk M., Tyszczuk K. and Korolczuk M., Electroanalysis, 18, 70 (2005).
  • 16.Korolczuk M. and Tyszczuk K., Anal. Chim. Acta, 580, 231 (2006).
  • 17.Korolczuk M., Tyszczuk K. and Grabarczyk M„ Talanta, 72, 957 (2007).
  • 18.Tyszczuk K. and Korolczuk M„ Electroanalysis, 19, 1539 (2007).
  • 19.Korolczuk M. and Tyszczuk K, Electroanalysis, 19, 1959 (2007).
  • 20.Korolczuk M. and Tyszczuk K„ Chem. Anal. (Warsaw), 52, 1015 (2007).
  • 21.Tyszczuk K„ Anal. Bioanal. Chem, 390, 1951 (2008).
  • 22.US EPA (2003). Drinking water contaminants. http://www.epa.gov/safewater/contaminants.index.html.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0095-0088
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.