PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

A multipulse diode converter with small active power filter

Autorzy
Identyfikatory
Warianty tytułu
Konferencja
Scientific Conference on Computer Applications in Electrical Engineering [13; April 14-16, 2008; Poznan]
Języki publikacji
EN
Abstrakty
EN
The article presents the principle of operation and results of simulation tests of a selected system of the 12-pulse converter with direct voltage output, cooperating with a small active power filter (APF). The presented system makes it possible to reduce, especially in autonomous supply networks, undesired higher harmonics in the network current. The 12-pulse nature of operation of the converter is reached using a set of coupled three-phase network reactors (CTR). Simultaneous use of the magnetically coupled reactors and the small active power filter provides opportunities for easy and cheap reduction of the THD coefficient, down to the values acceptable by clean power converters (CPC) conditions.
Rocznik
Tom
Strony
7--16
Opis fizyczny
Bibliogr. 9 poz.
Twórcy
autor
  • Gdynia Maritime University
Bibliografia
  • [1] Aredes M., Active Power Line Conditioners, The doctor engineer dissertation, Technical University of Berlin, Berlin, (1996).
  • [2] Depenbrock M., Niermann C., A New 18-pulse Rectifier Circuit with Line-side Interphase Transformer and Nearly Sinusoidal Line Currents, Proceedings of the 2nd International Power Electronics Conference (IPEC), Tokyo, (1990), 539-546.
  • [3] Miyairi S., Iida S., Nakata K.., Masukawa S., New Method for Reducing Harmonics Involved in Input and Output of Rectifier with Interphase Transformer, IEEE Transactions on Industry Applications, vol. IA-22, (1986), no.5, 986-992.
  • [4] Mysiak P., The DC-output Multipulse Converter in the Low Voltage Power Network Supply Conditions, (in Polish), Ph.D. dissertation, Warsaw Technical University, Warsaw, Poland, (1996).
  • [5] Mysiak P., A multi-pulse diode rectifier with a coupled three-phase reactor - the design method and results of the simulation and laboratory tests, Electrical Power Quality and Utilisation Journal, Volume XI, (2005), Number 1 - ISSN 1234-6799, 83-92.
  • [6] Supronowicz H., Strzelecki R., Power Factor in AC-power Supplying Systems and Its Improvement Methods, (in Polish), Publishing House of Warsaw Technical University, Warsaw, Poland, (2000).
  • [7] Tunia H., Barlik R., Mysiak P., The Three-phase Coupled Reactors System for Current Higher Harmonics Reducing in the Three-phase Load Supplying from Voltage Source Inverters, (in Polish), Electrical Power Quality and Utilisation Journal, AGH University of Science and Technology, Cracow, Poland, Volume IV, Book I, (1998), 13-21.
  • [8] Wojciechowski D., Novel estimator of distorted and unbalanced electromotive force of the grid for control system of PWM rectifier with active filtering, Proceedings of the 11th European Conference on Power electronics and applications - EPE 2005, Dresden, Germany, (2005), 78-89.
  • [9] Wojciechowski D., Grid voltages sensorless control of PWM rectifier with active filtering, Electrical Power Quality and Utilisation Journal, Volume XII, (2006), Number 1, (ISSN 1234-6799), 43-48.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0092-0033
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.