Sensitive determination of methyl-parathion in contaminated water using single-walled carbon nano-tube film electrode

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Czuła metoda oznaczania metyloparationu w zanieczyszczonej wodzie, przy użyciu elektrody pokrytej jednościennymi nanorurkami węglowymi
Języki publikacji
EN
Abstrakty
EN
A sensitive voltammetric procedure for the determination of methyl-parathion at a glassy carbon electrode (GCE) modified with a single-walled carbon nano-tube (SWCNT) / dicetyl phosphate (DCP) composite film has been developed. The electrochemical behaviours of methyl-parathion at the composite film electrode are investigated with voltammetry. The results indicate that the fabricated film electrode exhibits excellent electrocatalytic activity towards the reduction of methyl-parathion after being pre-concentrated. Experimental parameters, such as thickness of the SWCNT/DCP film, pH of the supporting electrolyte and accumulation conditions have been optimized. Under the optimal conditions, a linear response between the reduction peak current and the methyl-parathion concentration is obtained from 5.0 x 107 to 1.0 x 101 mol L-1 with a detection limit of 2.0 x 107 mol L-1>. The advantages of the proposed procedure are demonstrated by the successful determination of methyl-parathion in the contaminated south-lake water without pretreatment.
PL
Opracowano czułą, woltamperometrycznąmetodę oznaczania metyloparationu z użyciem elektrody z węgla szklistego zmodyfikowanej błonką kompozytową z jednościennych nanorurek węglowych i fosforanu dicetylu. Zbadano elektrochemiczne właściwości metyloparationu. Otrzymane wyniki wskazują, że zastosowana elektroda katalizuje redukcję metyloparationu po jego zatężeniu na powierzchni elektrody. Wyznaczono optymalne wartości parametrów eksperymentalnych: grubości błonki, pH elektrolitu podstawowego i warunków zatężania. W optymalnych warunkach zależność prądu redukcji od stężenia metyloparationu była liniowa w zakresie od 5,0 x 107do l,0 x l01 mol L-1>. Granica wykrywalności wynosiła 2,0 x 107 mol L"1. Metodę zastosowano z powodzeniem do oznaczania metyloparationu w skażonej wodzie z jeziora bez konieczności uzdatniania wody do analizy.
Czasopismo
Rocznik
Strony
201--214
Opis fizyczny
Bibliogr. 28 poz.
Twórcy
autor
autor
autor
autor
  • Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science, South-Central University for Nationalities, Wuhan 430074, China, lichychem@163.com
Bibliografia
  • 1. Li C.Y., Wang C.F., Ma Y. and Hu S.S., Microchim. Ada, 148, 27 (2004).
  • 2. Mulchandani P., Chen W. and Mulchandani A., Environm. Sci. Technol., 35, 2562 (2001).
  • 3. Mulchandani A., Chen W.. Mulchandani P., Wang J. and Rogers K.R., Biosensors Bioelectron., 16, 225 (2001).
  • 4. Herrera A., Perez-Arquillue C., Conchello P., Bayarri S., Lazaro R., Yague C. and Arino A., Anal. Bioanal. Chem., 381, 695 (2005).
  • 5. Schellin M„ Hauser B. and Popp P., J. Chromato. A, 1040, 251 (2004).
  • 6. Sotiropoulou S. and Chaniotakis N.A.. Anal. Chim. Acta. 530, 199 ( 2005).
  • 7. Bucur B., Danet A.F. and Marty J.L.. Biosens. Bioelectron., 20, 217 ( 2004).
  • 8. Deo R.P., Wang J., Block I., Mulchandani A., Joshi K.A., Trojanowicz M., Scholz F., Chen W. and Lin Y.H., Anal. Chim. Acta, 530, 185 ( 2005).
  • 9. Pedrosa V.A., Caetano J., Machado S.A.S., Freire R.S. and Bertotti M., Electroanal., 19,616 (2007).
  • 10. Mulchandani P., Mulchandani A., Kaneva I. and Chen W., Biosens. Bioelectron., 14, 77 (1999).
  • 11. Xu C.L., Wu K.B., Hu S.S. and Cui D.F., Anal. Bioanal. Chem., 373, 284 (2002).
  • 12. De Souza D. and Machado S.A.S., Electroanal., 18, 862 (2006).
  • 13. Zen J. M., Jou J.J. and Kumar A.S.A., Anal. Chim. Acta, 396, 39 (1999).
  • 14. Manisankar P., Viswanathan S., Pusphalatha A.M. and Rani C., Anal. Chim. Acta, 528, 157 (2005).
  • 15. Manisankar P., Selvanathan G. and Vedhi C., Talanta, 68, 686 (2006).
  • 16. Liu G.D. and Lin Y.H., Anal Chem., 77, 5894 (2005).
  • 17. Liu G.D. and Lin Y.H., Eledrochem. Commun., 7, 339 (2005).
  • 18. Li C.Y., Wang C.F., Wang C.H. and Hu S.S., Sens. Actual. B: Chem., 117, 166 (2006).
  • 19. Li C.Y., Wang C.F., Wang C.H. and Hu S.S., Anal. Chim. Acta, 545, 122 (2005).
  • 20. Li C.Y., Wang C.F., Guan B„ Zhang Y.Y. and. Hu S.S., Sens. Actual. B: Chem., 107, 411 (2005).
  • 21. Li C.Y., Wang C.F., Ma Y„ Bao W. and Hu S.S., Anal. Bioanal. Chem., 381, 1049 (2005).
  • 22. Iijima S., Nature, 354, 56 (1991).
  • 23. Zhao Q., Gan Z. and Zhuang Q., Electroanal., 14 , 23 (2002).
  • 24. Zhao Y.F., Gao Y.Q., Zhan D.P., Liu H„ Zhao Q., Kou Y„ Shao Y.H., Li M.X., Zhuang Q.K. and Zhu Z.W., Talanta, 66, 51 (2005).
  • 25. Suprun E., Evtugyn G., Budnikov H., Ricci F., Moscone D. and Palleschi G., Anal. Bioanal. Chem., 383, 597 (2005).
  • 26. Yaico D., Albuquerque T. and Ferreira L.F., Anal. Chim. Acta, 596, 210 (2007).
  • 27. Lei Y., Mulchandani P., Wang J., Chen W. and Mulchandani A., Environ. Sci. Technol., 39, 8853 (2005).
  • 28. Ni Y.N., Qiu P. and Kokot S„ Anal. Chim. Acta, 516, 7 (2004).
Typ dokumentu