PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Systematic evaluation of a surface plasmon resonance imaging biochip reader: study of gold surface modifications (II)

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Systematyczna ocena obrazowania powierzchni bioczipu czytnikowego metodą rezonansu plazmonów: badanie modyfikacji powierzchni złota(II)
Języki publikacji
EN
Abstrakty
EN
The use ofthe Surface Plasmon Resonance phenomenon to create a two-dimensional image of a surface has become of importance in the field of proteornics and in the study ofthe interactions between biomolecules. One ofthe most critical steps in the preparation of a sample for Surface Plasmon Resonance measurements is the immobilization ofthe molecules on the metallic surface (usually gold). The most common procedure, implies the creation of a Self Assembled Monolayer of a thiol on the surface ofthe chip and the subsequent immobilization of biomolecules on it. In this paper, we describe a procedure of gold modification to bind proteins, and its application to study protein-protein interactions.
PL
Użycie zjawiska powierzchniowego rezonansu plazmonów do tworzenia przestrzennych obrazów powierzchni odgrywa ważna rolę wproleomice i badaniach oddziaływań biomo-lekuł. Jednym z najważniejszych kroków w przygotowaniu próbki do pomiarów metodą powierzchniowego rezonansu plazmonówjest proces immobilizacji biomolckul na metalicznej powierzchni (zazwyczaj złota). Najczęściej proces ten przebiega przez utworzenie mono warstwy tiolu na powierzchni złota, na której są immobilizowane biomolekuły. W pracy opisano procedurę modyfikacji powierzchni złota do immobilizacji biomolekuł i jej zastosowanie do badań interakcji białek.
Czasopismo
Rocznik
Strony
679--689
Opis fizyczny
Bibliogr. 27 poz.
Twórcy
autor
Bibliografia
  • 1.Homola J., Yee S.S. and Gauglitz G., Sens. Actuators B, 54, 3 (1999).
  • 2.Ferguson J., Baxter A., Young P., Kennedy G., Elliot C., Weigel S., Gatermann R., Ashwin H., Stead S., Sharman M., Anal. Chim. Acta, 529, 109 (2005).
  • 3.Indyk H.E. and Filonzi E.L., Int. Dair. Jour., 15, 429 (2005).
  • 4.McGrath T., Baxter A., Ferguson J., Haughey S. and Bjurling P., Anal. Chim. Acta, 529, 123 (2005).
  • 5.Shankaran D.R., Vengatajalabathy Gobi K., Sakai T., Matsumoto K., Toko K. and Miura N., Biosensors and Bioelectronics, 20, 1750 (2005).
  • 6.Arakawa T., Kawabayashi A. and Saga T., Sens. Actuators B, 108, 899 (2005).
  • 7.Jung J.M., Shin Y.B., Kim M.G., Ro H.S., Jung H.T. and Chung B.H., Anal. Biochem.,330, 251 (2004).
  • 8.Bassil N., Maillart E., Canva M., Levy Y., Millot M.C., Pissard S., Narwa R. and Goossens M., Sens. Actuators B, 94, 313 (2003).
  • 9.Xinglong Y., Dongsheng W., Dingxin W., Hua O.Y.J., Zibo Y., Yonggui D., Wei L. and Sheng Z.X., Sens. Actuators B, 91,133 (2003).
  • 10.Palumbo M., Pearson C., Nagel J. and Petty M.C., Sens. Actual B, 90, 264 (2003).
  • 11.Steiner G., Sablinskas V., Hübner A., Kühne Ch. and Salzer R., J. Mol. Struc., 509 ,265 (1999).
  • 12.Relia R., Spadavecchia J., Manera M.G., Siciliano P., Santino A. and Mita G., Biosensors and Bioelectronics, 20, 1140 (2004).
  • 13.Piliarik M., Vaisocherová H. and Homola J., Biosensors and Bioelectronics, 20, 2104 (2005).
  • 14.Huang S.H, Shih Y.C., Wu C.Y., Yuan C.J., Yang Y.S., Li Y.K. and Wu T.K., Biosensors and Bioelectronics, 19,1627 (2004).
  • 15.Zhao C. and Wittstock G., Biosensors and Bioelectronics, 20, 1277 (2005).
  • 16.Tantra R. and Cooper J., Sens. Actuators B, 82, 233 (2002).
  • 17.Steiner G., Anal. Bioanal. Chem., 379, 328 (2004).
  • 18.Ostuni E., Yan L. and Whitesides G.M., Colloids Surf. B, 15, 3 (1999).
  • 19.Bambad C.C, Sigal G., Strominger J.L. and Whitesides G.M., Biosensors and Bioelectronics, 12, VI, (1997).
  • 20.Boozer C., Yu Q., Chen S., Lee C-H., Homola J., Yee S.S. and Jiang S., Sens. Actuators B, 90 (2003).
  • 21.Liu F.K., Wie G.T. and Cheng F.C., J. Chin. Chem. Soc., 50, 931 (2003).
  • 22.ChakiN.K. and Vijayamohanan K., Biosensors and Bioelectronics, 17, 1 (2002).
  • 23.Lee W., Oh B.-K., Bae Y.M., Paek S.H., Lee W.H. and Choi J. W., Biosensors and Bioelectronics, 19, 185 (2003).
  • 24.Bell S.A., McLean M.E., Oh S.K., Tichy S.E., Zhang W., Corn R.M., Crooks R.M. and Simanek E.E., Bioconj. Chem., 14,488 (2003).
  • 25.Gorodkiewicz E., Fernández-González A., Akkoyun A., Steiner G. and Salzer R., Chem. Anal.(Warsaw), 50, 103 (2005).
  • 26.Yang Y., Yang M., Wang H., Jiang J., Shen G. and Yu R., Sens. Actuators B, 102, 162 (2004).
  • 27.Lee J.W., Sim S.J., Cho S.M. and Lee J., Biosensors and Bioelectronics, 20, 1422 (2005).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0066-0002
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.