PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Fast determination of ultra trace amounts of residual proteins in penicillin based on the enhancement in Rayleight light scattering spectra of phenylfluorone-Mo(VI) complex

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Szybka metoda oznaczania ultraśladowych ilości białek w penicylinie na zasadzie wzmocnienia widma rezonansowego rozproszenia światła kompleksu fenylofluoronu z Mo(VI)
Języki publikacji
EN
Abstrakty
EN
Determination of protein - phenylfluorone (PF)-Mo(VI) complex using Rayleigh light scattering (RLS) method in the presence of the OP emulsifier microemulsion has been performed. At pH = 2.72 the RLS spectrum of PF-Mo(VI) complex is enhanced in the presence of proteins. Such a behaviour was utilised in a new method for the quantitative determination of proteins. An OP emulsifier microemulsion was used in this determination to increase the sensitivity. Four proteins, including bovine serum albumin (BSA), human serum albumin (HSA), Lysozyme (Lys), and λ-globulin (λ - G) have been determined. The dynamic range for BSA was 0-80 ng mL-1 and the corresponding detection limit equaled 1.57 ng mL-1. The method is characterised by high sensitivity and simplicity, and provides results of satisfactory stability. It can be used for the determination of residual protein in penicillin samples. The relative standard deviations for the investigated proteins were less than 4.48%. and the recoveries were in the range of 96.35%-100.9%.
PL
Przeprowadzono oznaczanie kompleksu białko-fenylofluoren (PF)-Mo(VI) stosując metodę rezonansowego rozproszenia światła (RLS) w obecności emulgatora OP. W obecności białek, przy pH 2,72 widmo RLS kompleksu PF-Mo(VI) ulega wzmocnieniu. Właściwość tę wykorzystano w nowej metodzie ilościowego oznaczania białek. Dodanie emulgatora OP znacznie poprawiało czułość. Oznaczono w ten sposób cztery białka: albuminę wolową (BSA). albuminę ludzką (HSA). lizozym (Lys) i λ λ-globulinę. Zakres dynamiczny BSA wynosił 0-80 ng mL-1, a granica wykrywalności - 1,57 ng mL-1. Metoda charakteryzuje się wysoką czułością! prostotą oraz dobrą powtarzalnością wyników. Względne odchylenie standardowe oznaczanych białek było niższe od 4,48% a odzyski zawierały się w granicach 96,35-100,9%.
Czasopismo
Rocznik
Strony
795--806
Opis fizyczny
Bibliogr. 28 poz.
Twórcy
autor
  • School of Chemistry & Chemical Engineering, Jinan University, Jinan 250022, P.R. China
autor
  • School of Chemistry & Chemical Engineering, Jinan University, Jinan 250022, P.R. China
autor
  • School of Chemistry & Chemical Engineering, Jinan University, Jinan 250022, P.R. China
autor
  • School of Chemistry & Chemical Engineering, Jinan University, Jinan 250022, P.R. China
autor
  • School of Chemistry & Chemical Engineering, Jinan University, Jinan 250022, P.R. China
autor
  • College of Chemical and Material Engineering, Southern Yangtze University, Wuxi 214036, P. R. China
Bibliografia
  • 1. Stoscheck C.M., Anal Biochem., 160, 301 (1987).
  • 2. Bradford M.M., Anal. Biochem., 72, 248 (1976).
  • 3. Fujita Y., Mori I., Ikuta K., Nakahashi Y. and Kato K., Chem. Pharm. Bull., 37, 2452 (1989).
  • 4. Ma C.Q., Li K.A. and Tong S.Y., Anal. Chim. Acta., 333, 83 (1996).
  • 5. Qin W.W., Gong G.Q. and Song Y.M., Spectrochim. Acta Part A, 56, 1021 (2000).
  • 6. Nukatsuka I., Nishimura A. and Ohzeki K., Anal. Chim. Acta, 304, 243 (1995).
  • 7. Winkler W. and Arenhla A., Talanta, 53, 277 (2000).
  • 8. Winkler W., Buhl F., Arenhövel-Pacula A. and Hachula U., Anal. Bioanal.Chem., 376, 934 (2003).
  • 9. Li Z.J., Ou Z. P. and Pan J.M., Rev. Anal. Chem., 22, 257(2003).
  • 10. Wei Q., Wu D., Du B. and Ou Q.Y., Chin. Chem. Lett., 15, 667 (2004).
  • 11. Du B., Wei Q. and Xu G.Y., Anal. Lett., 32, 1011 (1999).
  • 12. Du B., Yang J.H., Wei Q. and Chang G.H., Anal. Lett., 35, 895 (2002).
  • 13. Wei Q., Yang J.H., Zhang Y., Chang G.H. and Du B., Talanta, 58, 419 (2002).
  • 14. Wei Q., Yan L.G., Chang G.H. and Ou Q.Y., Talanta, 59, 253 (2003).
  • 15. Chen L.H., Zhao F.L. and Li K.A., Chin. J. Chem., 20, 368 (2002).
  • 16. Zhao Y.K., Chang W.B. and Ci Y.X., Talanta, 59, 477 (2003).
  • 17. Chen Y.J., Yang J.H., Wu X., Wu T. and Luan Y.X., Talanta, 58, 869 (2002).
  • 18. Liu S.P., Yang R. and Liu Q., Anal. Sci., 17, 243 (2001).
  • 19. Guo Z.X. and Shen H.X., Spectrochim. Acta Part A, 55, 2919 (1999).
  • 20. Dong L.J., Jia R.P., Li Q.F., Chen X.G., Hu Z.D. and Hooper M.A., Fresenius J. Anal. Chem., 370, 1009 (2001).
  • 21. Jia R.P., Dong L.J., Li Q.F., Chen X.G., Hu Z.D. and Nagaosa Y., Anal. Chim. Acta., 442, 249 (2001).
  • 22. Guo Z.X. and Shen H.X., Anal. Chim. Acta, 408, 177 (2000).
  • 23. Wang L., Li Y.X., Zhu C.Q. and Zhao D.H., Microchim. Acta, 143, 275 (2003).
  • 24. Zhong H., Li N., Zhao F.L. and Li K.A., Talanta, 62, 37 (2004).
  • 25. Li Y.F, Huang C.Z. and Li M., Anal. Sci., 18, 177 (2002).
  • 26. Cong X., Guo Z.X., Wang X.X. and Shen H.X., Anal. Chim. Acta, 444, 205 (2001).
  • 27. Chen X.L., Li D.H., Zhu Q.Z., Yang H.H., Zheng H., Wang Z.H. and Xu J.G., Talanta, 53, 1205 (2001).
  • 28. Dong L.J., Jia R.P., Li Q.F., Chen X.G. and Hu Z. D., Anal. Chim. Acta, 459, 313 (2002).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0049-0096
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.